6. CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
We recommend a frequent cleaning of the speaker system. Please use a soft lint-free and moistened cloth.
Never use alcohol or solvents!
There are no serviceable parts inside the speaker system. Maintenance and service operations are only to
be carried out by authorized dealers.
If the speaker system distorts, it may be defective. Test the speaker system once more with another
amplifier. If the sound remains distorted, the speaker system should not be operated any more in order to
prevent further damage. Please contact your dealer.
Should you have further questions, please contact your dealer.
7. TECHNICAL SPECIFICATIONS
Input voltage: 100 V
Speaker: 15 cm (6")
Rated power: 3 W RMS (white)
6 W RMS (red)
COM (black)
Sensitivity (1 W/ 1 m): 91 dB, ±3 dB
Max. SPL: 97 dB
Frequency range: 100 Hz - 17 kHz
Dimensions (D x D): 188 x 70 mm
Mounting cutout: 170 mm ø
Weight: 500 g
Please note: Every information is subject to change without prior notice. 09.09.2010 ©

Chat with your Omnitronic CSP-6 manual using AI

Get instant AI answers from your Omnitronic CSP-6 manual

Ask anything about the Omnitronic CSP-6. Answers come from this manual, with the pages they are based on.

CSP-6 Maintenance Schedule

Remind me when maintenance is due
Yearly
Inspect safety installations by a skilled person

The operator must ensure that safety-relating and machine-technical installations are inspected by a skilled person once a year.

Show in the manual (page 10)
Every 4 Years
Expert inspection of safety installations

The operator must ensure that safety-relating and machine-technical installations are inspected by an expert every four years as part of an acceptance test.

Show in the manual (page 10)
Regularly
Clean the speaker surface

Frequently clean the speaker with a soft, lint-free, moistened cloth. Never use alcohol or solvents.

Show in the manual (page 10)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend CSP-6?

Yes No

Frequently Asked Questions

A

No, it is designed for indoor environments only. Outdoor installation may lead to moisture damage and void safety standards regarding humidity and heat.

Is this answer helpful?

A

Only qualified electricians should make electrical connections due to high voltage risks and safety regulations regarding PA system cabling.

Is this answer helpful?

A

Use a soft damp cloth. Do not use alcohol or solvents to avoid damaging the plastic casing or safety features.

Is this answer helpful?

A

Reduce volume immediately. Continued overload can permanently damage speakers and void warranty protection due to heat stress.

Is this answer helpful?

A

Yes, relative humidity must not exceed 50 percent at 45 degrees Celsius to ensure function and prevent electrical issues.

Is this answer helpful?

A

No, unauthorized modifications are forbidden due to safety reasons and warranty voidance regarding fire and electrical hazards.

Is this answer helpful?

A

The required mounting cutout is 170 millimeters in diameter according to technical specifications for proper flush fitting.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • 100-volt system ideal for multi-zone installations in PA environments
  • 91 dB sensitivity ensures clear and high-quality audio output
  • Compact size fits well into ceilings without obstructing space
  • Rated for indoor use with specific temperature and safety limits
VS

Disadvantages

  • Indoor use only prevents outdoor or damp room deployment
  • Requires qualified electrician for proper wiring and safety
  • No serviceable parts inside the housing for user repair
  • Overloading or distortion voids the warranty protection
M: QW-35-FL

Product Specification

Shape

Round

Design

1-Way

Woofer

1 x 6"

Frequency Response

100Hz - 17kHz

Power Handling

6W RMS, 12W Peak

Sensitivity

91dB

Cutout Dimensions

6.50" x 6.50"

Mounting Depth

2.76"

Color

White

Dimensions (WxHxD)

7.40" x 7.40" x 2.76"

Weight

1.15 lbs

M: QW-35-FL

Product Description

Achieving Superior Sound with Ceiling Speakers

Integrating high quality audio into your environment requires selecting durable components. The Omnitronic CSP-6 white stands out as a robust choice for ceiling environments. This speaker utilizes a 100-volt system architecture, making it ideal for multi-zone installations. Users seeking clarity and reliability will find this model effective for public address applications. It delivers a sensitivity of 91 dB for clear audio reproduction.

Detailed Installation Procedures

Proper mounting ensures longevity and safety. The installation area must handle at least five times the point load of the device weight. Sawing the correct cutout is the first step. Follow the Omnitronic CSP-6 white Manual guidelines for dimensions to achieve a flush fit. Always verify that the location is fire-resistant and vibration-free. Electrical connections should only be made by trained electricians to prevent life-threatening hazards. Ensure all terminals are connected strictly to the amplifier output.

Operational Performance

Operating the speaker involves balancing power and audio quality. The unit supports multiple wattage settings via terminal selection. Always ensure the amplifier matches the power load requirements to prevent damage. Listen for distortion during use, as this indicates potential overload. If distortion occurs, reduce the volume immediately. Regular checks with a sound level meter help maintain compliance with safety standards. This prevents hearing loss and equipment failure.

Safety and Environmental Limits

The device is designed for indoor environments only. Do not install these units in damp rooms or humid areas. Temperature must remain between -5 and 45 degrees Celsius. Humidity levels exceeding 50 percent at high temperatures can cause failure. Keep children away from the equipment. Never block the speaker with heat insulation or vapor foils to avoid burning risks. Operating altitude must be between negative 20 and 2000 meters above sea level.

Maintenance Protocols

Regular cleaning prevents dust accumulation. Use a soft, lint-free, and damp cloth for maintenance. Avoid alcohol or solvents which may damage the plastic casing. The internal housing has no serviceable parts. Professional servicing is required for internal repairs. Inspect connections annually to ensure continued safety compliance. If sound quality degrades permanently, contact a specialized workshop.

Technical Data Overview

The unit measures 188 by 70 millimeters and weighs 500 grams. Frequency range spans 100 Hz to 17 kHz ensuring full coverage. Maximum sound pressure reaches 97 dB. Input voltage is rated at 100 V for compatibility with standard PA systems.

This comprehensive guide ensures your investment remains safe and effective for years.

M: QW-35-FL

© Copyright 2026 Manual.ly