84f42a056d1faa756adef8d0341a19bc2cb1 page 32
EN - 2
ENGLISH
DISPOSAL
This symbol on the product or its packaging indicates that the appliance cannot be treated as
normal domestic trash, but must be handed in at a collection point for recycling electric and
electronic appliances. Your contribution to the correct disposal of this product protects the
environment and the health of your fellow men. Health and the environment are endangered
by incorrect disposal. Further information about the recycling of this product can be obtained
from your local town hall, your refuse collection service, or in the store at which you bought
the product. This regulation is valid only in EU member states.
3.5.13 - Timer and clock setting ................................................................................................32
3.5.14 - Timer setting (PROGR. 1 and PROGR. 2) ..................................................................33
3.5.15 - Timer activation and deactivation .................................................................................34
3.5.16 - Reset of all the remote control functions ......................................................................34
3.5.17 - Managing the unit if the remote control is not available ...............................................34
3.6 - RECOMMENDATIONS FOR ENERGY SAVINGS .....................................................................34
4 - MAINTENANCE AND CLEANING .....................................................................................35
4.1 - CLEANING .................................................................................................................................35
4.1.1 - Appliance and remote control cleaning ..........................................................................35
4.1.2 - Cleaning the air lter.......................................................................................................36
4.2 - MAINTENANCE .........................................................................................................................37
4.2.1 - Routine maintenance ...................................................................................................37
4.2.2 - Condensation water drainage in case of emergency .....................................................37
4.3 - DIAGNOSIS, ALARMS AND INCONVENIENCES .....................................................................38
4.3.1 - Diagnosis of the inconveniences ....................................................................................38
4.3.2 - Functional aspects not to be mistaken for anomalies.....................................................38
4.3.3 - Console led signals ........................................................................................................39
4.3.4 - Anomalies and remedies ................................................................................................40
OPERATING LIMIT
CONDITIONS
INDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
Maximum operating temperatures in
cooling mode
DB 35°C - WB 24°C DB 43°C - WB 32°C
Minimum operating temperatures in
cooling mode
DB 18°C DB -10°C
Maximum operating temperatures in
heating mode
DB 27°C DB 24°C - WB 18°C
Minimum operating temperatures in
heating mode
- - - DB -15°C
TECHNICAL DATA

Chat with your Olimpia Splendid Unico Air 8 manual using AI

Get instant AI answers from your Olimpia Splendid Unico Air 8 manual

Ask anything about the Olimpia Splendid Unico Air 8. Answers come from this manual, with the pages they are based on.

Unico Air 8 Maintenance Schedule

Remind me when maintenance is due
Every 2 weeks
Clean or wash the air filter

Clean or wash the room air filter every 2 weeks, or whenever its red indicator LED lights.

Show in the manual (page 45)
Yearly
Inspect for refrigerant leaks

If a leak-detection device is installed, have leak checks performed at least every 12 months and keep inspection records.

Show in the manual (page 56)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: gpt-5.6-terra

Ask a Question

0/1000

Do you recommend Unico Air 8?

Yes No

Frequently Asked Questions

A

It provides cooling, dehumidification, and fan-only operation. Heat-pump versions also provide heating. Automatic comfort mode adjusts operation to room conditions, while Silent mode is designed for quieter overnight use.

Is this answer helpful?

A

The unit is designed as an all-in-one wall-mounted air conditioner rather than a conventional split system with a separate external condenser. It still requires installation on an exterior-facing wall with dedicated air intake and discharge openings.

Is this answer helpful?

A

Installation, initial start-up, electrical connections, and technical maintenance must be performed by authorized and qualified personnel. This is important because the appliance includes pressurized refrigerant and electrical components.

Is this answer helpful?

A

Disconnect power, remove the filter carefully, clean and dry it thoroughly, then reinstall it. The filter should generally be cleaned every two weeks or when the red filter indicator is illuminated.

Is this answer helpful?

A

Yes. The remote control can activate continuous flap swing or stop the flap at a preferred vertical airflow direction. The outlet flap should not be forced manually.

Is this answer helpful?

A

Choose a strong exterior-facing wall with adequate clearances and unobstructed airflow. Avoid heat sources, excessive humidity, explosive or flammable gases, and locations where the airflow would blow directly onto nearby people.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • All-in-one wall-mounted design avoids a separate outdoor condenser unit.
  • Offers cooling, dehumidification, ventilation, automatic comfort control, and heating on heat-pump versions.
  • Remote control supports airflow swing, fan speeds, Silent mode, clock, and two timer programs.
  • User-maintainable air filters can be cleaned regularly to support airflow and performance.
  • Can be configured for high-wall or low-wall installation to suit room layout.
VS

Disadvantages

  • Installation requires two 162 mm wall openings and an exterior-facing wall.
  • Installation, electrical work, start-up, and most maintenance require authorized qualified personnel.
  • Uses R410A refrigerant, which requires certified handling and must not be released into the atmosphere.
  • The listed Free Cooling remote function is not available for this model.
  • Heat-pump versions may temporarily stop delivering warm air during defrosting.
M: gpt-5.6-terra

Product Specification

Cooling capacity

1.8 kW

Dehumidification capacity

1.27 pt/24 hr

Fan function

Yes

Air circulation

241.3 CFM

Refrigerant

R410A

Features

Optional remote control, air filtration, automatic temperature control, 24-hour timer (adjustable)

Smart home

Optional app control (Wi-Fi)

Mounting type

Wall-mounted

Noise level

Max. 53 dB

Dimensions

38.5 x 19.33 x 6.46 in (W x H x D)

Weight

90.39 lb

M: gpt-5.6-terra

Product Description

Olimpia Splendid Unico Air 8 - Read, Download & Print Free

The Olimpia Splendid Unico Air 8 is a wall-mounted air conditioning solution designed to create a more comfortable indoor climate without the need for a traditional external condenser unit. Its compact all-in-one concept makes it an interesting choice for rooms where exterior space, building rules, or installation layout make split systems less practical.

Flexible Comfort for Everyday Spaces

This model is designed to cool and dehumidify indoor air, while fan-only operation can support air circulation when temperature adjustment is not needed. Heat-pump versions can also provide heating, giving users a practical option for seasonal comfort. Automatic comfort mode adjusts operation according to room conditions and the chosen temperature, while the Silent mode is intended to reduce noise and adjust settings gradually during the night.

Airflow can be directed through an adjustable outlet flap, with continuous swing available from the remote control. Fan speed can be selected manually at low, medium, high, or automatic levels. The unit also includes timer programming, allowing users to schedule operation around daily routines. Two separate timer programs can be configured for added flexibility.

Installation Considerations

The Olimpia Splendid Unico Air 8 is fitted on an exterior-facing wall and uses two wall openings for air intake and discharge. Correct placement is essential: airflow must remain unobstructed, the wall must safely support the unit, and the required clearances around the appliance must be respected. Installation, first start-up, electrical work, and technical servicing require authorized, qualified personnel.

The unit uses R410A refrigerant, an odorless fluorinated greenhouse gas. Refrigerant handling, repairs, leak checks, removal, and recycling must therefore be handled by certified technicians. The appliance should be placed in a well-ventilated location away from continuous ignition sources, excessive humidity, explosive gases, and strong heat sources.

Convenient Daily Control

A supplied infrared remote control manages standby, operating modes, temperature, fan speed, airflow direction, Silent mode, and timer settings. The remote has an approximate operating range of 8 meters when batteries are charged and there are no significant obstructions. If the remote is unavailable, the unit can be operated in automatic mode through its onboard control.

Routine care is straightforward. The air filter should be cleaned regularly, typically every two weeks or when the filter indicator lights up. The appliance must be disconnected from power before cleaning. Use a dry cloth or a cloth lightly dampened with cold water, and avoid corrosive cleaners, solvents, or direct water spray.

Notes

  • Keep doors and windows closed during climate control for better efficiency.
  • Do not block indoor or outdoor air passages with furniture, curtains, plants, or other objects.
  • Heat-pump operation may briefly pause warm-air delivery during automatic defrosting.
  • Professional maintenance helps preserve performance and supports safe refrigerant handling.