EN - 1
ENGLISH
MAIN INDEX
DISPOSAL
This symbol on the product or its packaging indicates that the appliance cannot be treated as normal domestic
trash, but must be handed in at a collection point for recycling electric and electronic appliances. Your contribution
to the correct disposal of this product protects the environment and the health of your fellow men. Health and
the environment are endangered by incorrect disposal.
Further information about the recycling of this product can be obtained from your local town hall, your refuse
collection service, or in the store at which you bought the product.
This regulation is valid only in EU member states.
0 - WARNINGS ..................................................................................................................................................................2
0.1 - GENERAL INFORMATION ..................................................................................................................................................2
0.2 - SYMBOLS ...........................................................................................................................................................................2
0.2.1 - Editorial pictograms..........................................................................................................................................2
0.3 - GENERAL WARNINGS ....................................................................................................................................................... 4
0.4 - PROPER USE ..................................................................................................................................................................... 8
0.5 - HAZARDOUS ZONES .........................................................................................................................................................8
0.6 - WARNINGS FOR R290 REFRIGERANT GAS ...................................................................................................................9
1 - DESCRIPTION OF THE APPLIANCE .......................................................................................................................16
1.1 - LIST OF THE COMPONENTS SUPPLIED ....................................................................................................16
1.2 - IDENTIFICATION OF THE MAIN COMPONENTS .......................................................................................16
2 - INSTALLATION ..........................................................................................................................................................17
2.1 - HOW TO TRANSPORT THE CONDITIONER ................................................................................................17
2.2 -
WARNINGS ....................................................................................................................................................................... 17
2.3 - MOBILE INSTALLATION ................................................................................................................................ 18
2.4 - FIXED INSTALLATION ................................................................................................................................... 18
2.5 - ELECTRICAL CONNECTION ........................................................................................................................18
2.6 - DRAINAGE ..................................................................................................................................................... 19
2.6.a - Use as dehumidier .......................................................................................................................................19
3 - USE OF THE APPLIANCE .........................................................................................................................................19
3.1 - CONTROL PANEL SYMBOLS AND KEYS ...................................................................................................19
3.2 - REMOTE CONTROL KEYS .........................................................................................................................20
3.3 - USE OF THE REMOTE CONTROL ...............................................................................................................21
3.3.a - Insertion of batteries.......................................................................................................................................21
3.3.b - Replacement of batteries ...............................................................................................................................21
3.3.c - Location of the remote control........................................................................................................................22
3.4 - USE OF THE APPLIANCE .............................................................................................................................22
3.4.a - Preliminary operations....................................................................................................................................22
3.4.b - Appliance switching on/off ..............................................................................................................................23
3.5 - VENTILATION MODE (FAN) ..........................................................................................................................23
3.6 - COOLING MODE (COOL) ..............................................................................................................................23
3.7 - DEHUMIDIFICATION MODE (DRY) ..............................................................................................................23
3.8 - AUTO MODE (Automatic) ..............................................................................................................................24
3.9 - NIGHT FUNCTION ......................................................................................................................................... 24
3.10 - TIMER MODE .................................................................................................................................................24
3.10.a Programmed switching on..............................................................................................................................24
3.10.b Programmed switching off ..............................................................................................................................24
3.11 - SETTING THE UNIT OF MEASUREMENT OF TEMPERATURE ..................................................................25
3.12 - AUTORESTART .............................................................................................................................................25
4 - MAINTENANCE AND CLEANING .............................................................................................................................25
4.1 - CLEANING .....................................................................................................................................................25
4.1.a - Cleaning the appliance and the remote control..............................................................................................25
4.1.b - Cleaning the suction lter ............................................................................................................................... 26
4.1.c - Recommendations for energy saving.............................................................................................................26
4.2 - MAINTENANCE .............................................................................................................................................26
4.2.a - Discharging condensation .............................................................................................................................. 27
4.2.b - Error codes .....................................................................................................................................................27
5 - TECHNICAL DATA .....................................................................................................................................................27
6 - INCONVENIENCES AND POSSIBLE REMEDIES ....................................................................................................28
7 - WIRING DIAGRAM ..................................................................................................................................................... 29

Chat with your Olimpia Splendid Dolceclima Compact 10P manual using AI

Get instant AI answers from your Olimpia Splendid Dolceclima Compact 10P manual

Ask anything about the Olimpia Splendid Dolceclima Compact 10P. Answers come from this manual, with the pages they are based on.

Dolceclima Compact 10P Maintenance Schedule

Remind me when maintenance is due
Monthly
Clean the air filter

Wash the filter with water or a neutral detergent solution if very dirty. Ensure it is completely dry before reinstalling.

Show in the manual (page 36)
When indicated
Check filter cleaning alarm

The Fi alarm code appears on the display after extended use to indicate the filter needs cleaning.

Show in the manual (page 36)
As needed
Drain condensation water

Remove the drain plug and empty the water tray when the beep indicates the lower tray is full.

Show in the manual (page 37)
Regularly
Vacuum dust from grids

Disconnect power and vacuum dust or lint from the air grilles to prevent overheating.

Show in the manual (page 47)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend Dolceclima Compact 10P?

Yes No

Frequently Asked Questions

A

It is a portable air conditioner designed to cool indoor spaces, reduce humidity, and circulate air. It is built for flexible home use and can be moved to different rooms as needed.

Is this answer helpful?

A

No. Besides cooling, it also includes fan-only and dehumidification modes, plus auto and sleep functions. This makes it useful in different weather conditions and room comfort needs.

Is this answer helpful?

A

The unit is designed for relatively simple setup. It uses an exhaust hose and can be placed near a window or adapted for fixed installation. Proper positioning and ventilation are important for best results.

Is this answer helpful?

A

R290 is an efficient refrigerant, but it is also flammable, so the appliance must be used according to safety rules. That means good ventilation, proper room size, and careful maintenance are essential.

Is this answer helpful?

A

Clean the air filter regularly, keep the air inlets and outlets clear, and drain condensation when needed. It is also important to follow the recommended spacing around the unit.

Is this answer helpful?

A

Yes. The sleep mode is designed for nighttime comfort. It adjusts operation gradually to help maintain a more pleasant temperature while reducing the need for frequent changes.

Is this answer helpful?

A

It is a strong choice for people who want a portable, easy-to-use cooling solution for smaller rooms, temporary use, or spaces where a fixed air conditioner is not convenient.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Portable design makes it easy to move between rooms and use where cooling is needed most.
  • Offers cooling, fan, dehumidifying, auto, and sleep functions for flexible everyday comfort.
  • Remote control, timer, and simple panel controls make operation convenient and accessible.
  • Compact build suits homes where a permanent air-conditioning system is not practical.
VS

Disadvantages

  • Requires correct room size and ventilation because it uses R290 refrigerant.
  • Needs regular filter cleaning and condensation drainage to maintain performance.
  • Exhaust hose and window setup may take time to install properly.
  • Best suited for smaller spaces, so it may not be ideal for larger rooms or heavy heat loads.
M: OA-GPT-54-NAN

Product Specification

Energy Efficiency Class

A

Energy Consumption

1 kWh

Energy Efficiency Rating

2.6 (EER)

Cooling Capacity

8,871.57 BTU/h

Dehumidification Capacity

13.31 gal/24h

Fan Function

2 Fan Speeds

Air Circulation

173.63 CFM

Refrigerant

R290

Special Features

Remote Control, Casters, 12h Timer

Smart Home

no

Mounting Type

freestanding

Noise Level

47-52 dB(A)

Dimensions

13.58 x 27.68 x 13.98 in (W x H x D)

Weight

54.45 lb

Scope of Delivery

Remote Control

M: OA-GPT-54-NAN

Product Description

Olimpia Splendid Dolceclima Compact 10P

The Olimpia Splendid Dolceclima Compact 10P is a practical portable air conditioner designed for everyday comfort in small to medium rooms. It blends cooling, dehumidifying, and ventilation in a single compact unit, making it a flexible choice for homes that need seasonal relief without a permanent installation. If you are looking for a straightforward solution that can be moved from room to room, this model stands out for its simple setup and user-friendly controls.

One of the biggest strengths of the Dolceclima Compact 10P is its versatility. It can cool warm spaces during hot days, reduce excess humidity when the air feels heavy, and keep the room circulating with fan-only mode when full cooling is not necessary. The unit also includes automatic mode, sleep mode, and timer functions, helping users fine-tune comfort while managing energy use more efficiently. In the Olimpia Splendid Dolceclima compact 10P Manual, the operating logic is explained clearly, which makes it easier to get the best performance from the appliance.

The design is centered on mobility and convenience. With its compact size, castors, handle, and flexible exhaust setup, the air conditioner can be positioned near a window or adapted for more fixed use. That makes it especially appealing for renters, seasonal use, or anyone who wants cooling without complex home modifications. The included remote control adds another layer of ease, allowing adjustments from across the room.

Safety and maintenance are also key themes. The appliance uses R290 refrigerant, so it must be used in well-ventilated spaces and with proper room dimensions. Regular filter cleaning, careful drainage of condensation, and correct placement away from heat sources all help keep the unit working properly. The manual stresses these points because they directly affect both performance and long-term reliability.

Overall, the Dolceclima Compact 10P is best understood as a compact, adaptable, and practical air solution rather than a decorative appliance. It is built for people who value simple operation, portable comfort, and essential climate control features in one device.

Notes

  • Keep the filters clean for better airflow and efficiency.
  • Make sure the room size matches the safety requirements for R290 refrigerant.
  • Use the drainage system correctly when operating in dehumidification mode.
  • Leave enough space around the unit for proper ventilation and performance.
M: OA-GPT-54-NAN