EDL- 6
Order No. 1000263
4 Electrical Connection
WARNING During operation, there is a hazard
of contact with a dangerous voltage
of up to 100 V at the speaker cable.
Installation must always be carried
out by skilled personnel.
Observe the load of the speakers on the PA am-
plifier. Overload may damage the amplifier! The
total power of all speakers connected must not
exceed the amplifier power.
1) If the PA system is switched on, switch it off
completely before connecting it!
2) Connect the speaker via the screw terminals
(black core =negative pole).
3) When connecting several speakers, make sure
that all speakers have the same polarity and
that the PA amplifier is not overloaded.
5 Specifications
Power rating: . . . . . . . . 8 W
Frequency range: . . . . . 90 – 18 000 Hz
Sensitivity: . . . . . . . . . . . 90 dB (1 W/1 m)
Max. rated SPL: . . . . . . . 99 dB
Radiation angle: . . . . . . 90°
Voice coil:
. . . . . . . . . . . ⌀20 mm
Ambient temperature: . 0 – 40 °C
Outside diameter: . . . . . 193 mm
Mounting cutout: . . . . . ⌀170 mm
Mounting depth: . . . . . 65 mm
Total depth: . . . . . . . . . 72 mm
Weight: . . . . . . . . . . . . 492 g
Subject to technical modification.
PA Ceiling Speaker
These instructions are intended for installers
with sufficient knowledge of 100 V technol-
ogy for PA applications. Please read the in-
structions carefully prior to installation and
keep them for later reference.
1 Applications
This speaker is specially designed for applications
in PA systems. It is equipped with a transformer for
operation in 100 V systems.
2 Safety Notes
The speaker corresponds to all relevant directives
of the EU and is therefore marked with .
•
The speaker is suitable for indoor use only. Pro-
tect it against dripping water, splash water and
high air humidity. The admissible ambient tem-
perature range is 0 – 40 °C.
•
For cleaning only use a dry, soft cloth; never use
water or chemicals.
•
No guarantee claims for the speaker and no lia-
bility for any resulting personal damage or ma-
terial damage will be accepted if the speaker is
used for other purposes than originally intended,
if it is not correctly installed or connected, or if
it is overloaded.
If the speaker is to be put out of opera-
tion definitively, dispose of the speaker in
accordance with local regulations.
3 Mounting
1) Saw a hole of the corresponding size into the
ceiling (⌀170 mm).
2) Make the electrical connection (chapter 4).
3) Fold the two clamps upwards.
4) Insert the speaker into the ceiling cutout until
the clamps are folded down and the speaker is
clamped on the ceiling.
English

Chat with your Monacor EDL-6 manual using AI

Get instant AI answers from your Monacor EDL-6 manual

Ask anything about the Monacor EDL-6. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend EDL-6?

Yes No

Frequently Asked Questions

A

No, this speaker is designed exclusively for indoor use. It must be protected from dripping water, splash water, and high humidity to function correctly and safely.

Is this answer helpful?

A

The Monacor EDL-6 has a nominal power rating of 8 Watts. Ensure the total power of all connected speakers does not exceed your amplifier's capacity.

Is this answer helpful?

A

Connect via screw terminals using black wire for the negative pole. Always match polarity across all speakers to maintain phase alignment in the system.

Is this answer helpful?

A

You need to cut a circular opening with a diameter of 170 mm into the ceiling to accommodate the speaker housing and clamps properly.

Is this answer helpful?

A

Never use water or chemical cleaners. Only wipe the surface gently with a dry, soft cloth to avoid damaging the unit or causing electrical hazards.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Integrated 100-V transformer simplifies long-distance wiring
  • Wide 90-degree radiation angle ensures excellent room coverage
  • Compact 170 mm cutout fits standard ceiling grids easily
  • Compliant with all relevant EU safety directives
  • Robust frequency range supports both speech and music
VS

Disadvantages

  • Restricted to indoor use only due to moisture sensitivity
  • Installation requires skilled personnel familiar with high voltage
  • System overload can permanently damage connected amplifiers
  • Cleaning must avoid water or chemicals to prevent damage
  • Limited bass response starts at 90 Hz which may affect music quality
M: QW-35-FL

Product Specification

Form

round

Principle

1-way

Tweeter

1x 6"/152.4mm

Frequency range

90Hz-18kHz

Power handling

8W RMS

Sensitivity

90dB

Cutout dimensions

6.7x6.7in

Mounting depth

2.6in

Ceiling thickness max.

1in

Color

white

Dimensions (WxHxD)

7.6x7.6x2.8in

Weight

16.8oz

M: QW-35-FL

Product Description

Monacor EDL-6 Ceiling Speaker Review

The Monacor EDL-6 stands out as a premier choice for professional audio installers seeking reliable performance in ceiling-mounted applications. Designed specifically for public address systems operating on 100-Volt technology, this speaker integrates seamlessly into commercial and institutional environments where clear speech reproduction is paramount.

Engineered with precision, the unit features an integrated transformer that simplifies wiring across long distances while maintaining signal integrity. The compact design allows for a discreet installation with a cutout diameter of just 170 mm, ensuring it fits standard ceiling grids without disrupting architectural aesthetics. With a power handling capacity of 8 Watts and a frequency response spanning from 90 Hz to 18,000 Hz, the EDL-6 delivers robust sound coverage suitable for background music and emergency announcements alike.

Safety remains a core priority in its construction. The device adheres to all relevant EU directives, making it a compliant solution for modern building standards. However, users must strictly observe indoor-only usage guidelines to protect against moisture damage. The speaker operates effectively within ambient temperatures ranging from 0 to 40 degrees Celsius, ensuring durability in various climate-controlled spaces. Installation requires careful attention to polarity and total system load to prevent amplifier overload, a critical step for long-term reliability.

Key Features and Benefits

When integrating the Monacor EDL-6 into your audio infrastructure, you benefit from a balance of acoustic performance and ease of maintenance. The 90-degree radiation angle provides wide coverage, minimizing dead spots in large rooms. Its lightweight build at approximately 492 grams reduces stress on ceiling structures during mounting.

Important Notes

Always ensure the power system is completely off before connecting any terminals. Use only dry cloths for cleaning to preserve the finish and internal components. Improper installation or overloading voids warranty claims, so adhere strictly to technical specifications.

M: QW-35-FL

© Copyright 2026 Manual.ly