Manual.ly Logo

Milwaukee M18 BPFP-CST Switch Tank Manual

0.0 · 0 Ratings

PDF manual · 77 Pages

English

M: QW-35-FL
page

/ 77

Loading...
c4074dd3734766d1ff50ecc8201c0e9eb7aa page c
22 23
Remove nozzle (1) counterclockwise by hand.
Clean nozzle (1) and fi lter (2) after each use.
Insert fi lter (2) and mount nozzle clockwise by hand.
Düse (1) linksdrehend von Hand abschrauben.
Düse (1) und Filter (2) nach jedem Gebrauch reinigen.
Filter (2) einsetzen und Düse rechtsdrehend von Hand anschrauben.
Dévisser la buse (1) à la main dans le sens inverse des aiguilles d'une
montre.
Nettoyer la buse (1) et le fi ltre (2) avant chaque utilisation.
Insérer le fi ltre (2) et visser la buse à la main dans le sens des aiguilles
d'une montre.
Rimuovere manualmente l'ugello (1) ruotando in senso antiorario.
Pulire l'ugello (1) e il fi ltro (2) dopo ogni utilizzo.
Inserire il fi ltro (2) ed avvitare l'ugello manualmente, ruotando in senso
orario.
Retire la boquilla (1) manualmente en sentido antihorario.
Limpie la boquilla (1) y el fi ltro (2) después de cada uso.
Introduzca el fi ltro (2) y monte la boquilla manualmente en sentido
horario.
Desaparafuse o bico (1) à mão, girando para a esquerda.
Limpe o bico (1) e o fi ltro (2) após cada uso.
Insira o fi ltro (2) e aparafuse o bico à mão, girando para a direita.
Sproeier (1) naar links met de hand losschroeven.
Sproeier (1) en fi lter (2) na elk gebruik reinigen.
Filter (2) plaatsen en sproeier naar rechts met de hand vastschroeven.
Skru dysen (1) af manuelt ved at dreje mod venstre.
Rengør dysen (1) og fi lteret (2) efter hver brug.
Sæt fi lteret (2) i og skru dysen på manuelt ved at dreje mod højre.
Skru dysen (1) av for hånden idet du vrir mot venstre.
Dysen (1) og fi lteret (2) skal rengjøres hver gang etter bruk.
Sett inn fi lteret (2) og skru på dysen for hånden idet du vrir mot høyre.
Skruva bort munstycket (1) för hand genom att vrida det åt vänster.
Rengör munstycket (1) och fi ltret (2) efter varje användning.
Sätt i fi ltret (2) och skruva fast munstycket för hand genom att vrida det åt
höger.
Ruuvaa suutin (1) vasemmalle kiertäen käsin irti.
Puhdista suutin (1) ja suodatin (2) joka käytön jälkeen.
Pane suodatin (2) paikalleen ja ruuvaa suutin oikealle kiertäen käsin
kiinni.
  (1)    .
  (1)   (2)    .
  (2)       .
Memeyi (1) elinizle sola çevirerek vidalayın.
Memeyi (1) ve fi
ltreyi (2) her kullanımdan sonra temizleyin.
Filtreyi (2) takın ve memeyi elinizle saa doru çevirerek vidalayın.
Trysku (1) levotoiv rukou odšroubujte.
Trysku (1) a fi ltr (2) po každém použití vyistte.
Filtr (2) nasate a trysku pravotoiv rukou pišroubujte.
Dýzu (1) avotoivo rukou odskrutkujte.
Dýzu (1) a fi lter (2) po každom použití vyistite.
Filter (2) nasate a dýzu pravotoivo rukou priskrutkujte.
Odkrci dysz (1), obracajc j rcznie w lewo.
Po kadym uyciu naley oczyci dysz (1) i fi ltr (2).
Woy fi
ltr (2) i rcznie przykr
ci dysz w prawo.
Balra forgatva csavarja le kézzel az (1) fúvókát.
Az (1) fúvókát (1) és a (2) szrt minden egyes használat után tisztítsa
meg.
Helyezze be a (2) szrt és jobbra forgatva csavarja fel kézzel a fúvókát.
Rono odvijte šobo (1) v levo.
Po vsaki uporabi oistite šobo (1) in fi lter (2).
Vstavite fi lter (2) in rono privijte šobo v desno.
Sapnicu (1) okretanjem ulijevo odvrtiti rukom.
Sapnicu (1) i fi ltar (2) poslije svake uporabe istiti.
Filtar (2) umetnuti i sapnicu okretanjem udesno uvrtiti rukom.
Griežot pa kreisi, ar roku noskrvjiet sprauslu (1).
Pc katras lietošanas iztriet sprauslu (1) un fi ltru (2).
Ievietojiet fi ltru (2) un, griežot pa labi, ar roku ieskrvjiet sprauslu.
Rankiniu bdu atsukite antgal (1), sukant prieš laikrodžio rodykl.
Po kiekvieno naudojimo išvalykite purkštuk (1) ir fi ltr (2).
dkite fi ltr (2) ir rankiniu bdu užsukite purkštuk pagal laikrodžio
rodykl.
Keerake düüs (1) käega vasakus suunas maha.
Puhastage düüs (1) ja fi lter (2) iga kasutuskorra järel.
Pange fi lter (2) sisse ja keerake düüs käega paremas suunas peale.
  (1) 
,
   
.
  (1)  (2)   .
  (2)   ,  
  .
  (1)     .
     (1)  (2).
  (2)      
.
Scoatei manual duza (1) prin rotire în sens antiorar.
Curai duza (1) i fi
ltrul (2) dup
fi ecare utilizare.
Introducei fi ltrul (2) i montai manual duza prin rotire în sens orar.
   (1)   .
   (1)  (2)   .
   (2)      .
  (1)    .
     (1)   (2).
  (2) 
 
  .
.    (1) 

.   (2)
 (1) 

.    
 (2)
 
1
2
1

Chat with your Milwaukee M18 BPFP-CST Switch Tank manual using AI

Get instant AI answers from your Milwaukee M18 BPFP-CST Switch Tank manual

Ask anything about the Milwaukee M18 BPFP-CST Switch Tank. Answers come from this manual, with the pages they are based on.

M18 BPFP-CST Switch Tank Maintenance Schedule

Remind me when maintenance is due
Every 6 months
Recharge stored battery

If the battery pack is stored for longer than 30 days, charge the pack normally every six months.

Show in the manual (page 21)
After each use
Clean nozzle and filter

Remove the nozzle counterclockwise by hand. Clean the nozzle and filter after every use.

Show in the manual (page 12)
After each use
Clean tank filters and reservoir

Clean filter (1), filter (2) and tank (3) after each use. Filters are available as spare parts.

Show in the manual (page 15)
Before each use
Inspect product for damage

Thoroughly inspect both the inside and outside of the product and examine components before each use.

Show in the manual (page 21)
After each use
Check for leaks

After each use, check all parts of the product for leaks. Return to an authorized service center if found.

Show in the manual (page 22)
After each use
Clean electrical contacts

Keep electrical contact posts between bottom of tank and base clean. Remove battery pack before cleaning.

Show in the manual (page 22)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend M18 BPFP-CST Switch Tank?

Yes No

Frequently Asked Questions

A

Salt water can corrode metal parts. It is best to avoid storing corrosive liquids inside the unit. Consult the manual for permitted fluid types to prevent damage to seals and internal components over time.

Is this answer helpful?

A

Clean the nozzle and filter after every single use with water. If blockage occurs turn off immediately disassemble parts gently and rinse thoroughly before reassembly to restore flow rates properly.

Is this answer helpful?

A

Typically the battery is not included in the base solo unit package. Check packaging details as buyers usually need to acquire compatible M18 batteries separately for initial operation.

Is this answer helpful?

A

The unit supports up to 15 liters of fluid volume. Overfilling beyond this limit may cause leakage or pressure issues. Always observe the max fill line markings on the transparent tank.

Is this answer helpful?

A

No. Do not leave residual chemicals in the tank after use. Drain and empty the container completely to avoid corrosion and dangerous fumes forming inside the sealed compartment.

Is this answer helpful?

A

Some variants support backpack configurations while others are standalone units. Verify your specific model number against the official specification sheet to confirm mounting capabilities.

Is this answer helpful?

A

Replace filters if they show signs of damage or permanent clogging. Inspect them during routine cleaning cycles to ensure uninterrupted spray patterns remain efficient throughout the season.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Cordless M18 system provides mobility without cords
  • Switchable tanks prevent chemical contamination between water and pesticides
  • Large 15 liter tank minimizes frequent refills during big jobs
  • Compatible with existing Milwaukee M18 battery ecosystem tools
  • Robust build quality designed for professional and heavy duty use
VS

Disadvantages

  • Weight increases significantly when tank is fully loaded with liquid
  • Requires regular deep cleaning to prevent nozzle clogging issues
  • Only accepts consumer grade chemicals not industrial strength substances
  • Battery pack sold separately often meaning extra initial investment cost
  • Chemical handling requires strict PPE and careful attention to labels
M: QW-35-FL

Product Specification

Battery

18V, Li-Ion

Tank Capacity

3.96 gal

Working Pressure

119.95 psi

Weight

7.94 lbs (without battery)

Package Contents

charger and battery not included, includes 2 nozzles, stainless steel spray wand

M: QW-35-FL

Product Description

Experience Cordless Freedom

Working on your property demands reliable equipment that adapts to various tasks. The Milwaukee M18 BPFP-CST Switch Tank Solo Cordless Pressure Sprayer Manual serves as a vital resource for understanding this versatile machine. Designed for both homeowners and professionals, this unit offers significant advantages over traditional electric or gas-powered sprayers. The core innovation lies in its ability to handle different fluids efficiently. By switching between dedicated tanks, users can manage household chemicals alongside plain water applications without cross-contamination risks. This flexibility makes it an essential addition to any shed or garage collection.

Safety First Principles

Operating heavy machinery requires diligence. The provided documentation stresses removing the battery pack before any work begins. This precaution prevents accidental startup during maintenance or cleaning. Ventilation is critical when applying pesticides or fungicides. Never spray near open flames or spark sources. Users should also wear approved personal protective equipment such as gloves and eye protection. Following these guidelines protects the operator and preserves the environment. It is vital to respect local regulations regarding chemical storage and disposal to maintain ecological balance while getting the job done effectively.

Maintenance and Care

Longevity depends on proper care. After every application, clean the nozzle and filter thoroughly to prevent clogging. Residual liquid must be stored in original containers or designated vessels to meet regulations. Tanks require washing with warm water and mild detergent occasionally. Do not use abrasive cleaners or hot boiling liquids which may damage hoses. Storage should occur in a cool dry place away from children. Regular inspection of seals and gaskets ensures optimal performance over time. Addressing minor issues early prevents costly repairs later.

Troubleshooting and Performance

Technical data indicates a maximum working pressure suited for various agricultural needs. Flow rates adjust based on the fluid viscosity used. The 15-liter capacity reduces refill interruptions during large jobs. Noise levels are monitored to ensure operator comfort during extended use. Using high capacity batteries extends run time significantly for large properties and complex layouts. Common issues like low pressure usually indicate a low battery or blockage. Understanding these metrics helps select the right accessory tips for specific crops or areas. Consistent pressure delivery guarantees even coverage across lawns or garden beds. Trusting the engineering behind the Milwaukee M18 BPFP-CST Switch Tank Solo Cordless Pressure Sprayer Manual ensures years of dependable service for your outdoor projects. Different variants allow customization for water only tasks versus chemical application ensuring you have the right tool for every situation.

M: QW-35-FL

© Copyright 2026 Manual.ly