f251f6a700218f0d7664ca90f1c237cd23f2 page 7
This ventilator has been developed for continuous operation to ensure the
necessary basic ventilation in buildings. Boost ventilation can be activated
manually (this requires a second, switched „L1“ phase) or via a humidity
sensor (a permanent „L“ phase is sufficient here) as needed.
Please read these installation instructions completely before starting work.
Caution
Ensure that all electric power is turned off before carrying out any work. The
electrical connections may only be conducted by a suitably qualified person
and must comply with the locally applicable regulations. If a fireplace with
chimney is used, care must be taken that sufficient air can enter the room being
ventilated.
Start-up/settings
12
13
14
Use the control panel to start-up and adjust the ventilator.
As soon as the ventilator is reconnected to the power supply, the two
buttons flash (12.1) and (12.2) for max. 15 minutes.
If you now press, for example, the button (12.1), the factory setting
„Boost ventilation/small bathroom“ is activated and flashes
(12.4).
Set the house switch for manual boost ventilation to OFF (no power to „L1“) and
switch the main circuit breaker back on.
Factory settings
Room Basic ventilation Boost ventilation
Small bathroom 18 m
3
/h 30 m
3
/h
Kitchen/large bathroom 30 m
3
/h 50 m
3
/h
Wall/ceiling installation
1–2
7–8
9–10
11
4
5–6
3
Remove the cover by turning counterclockwise, loosen the 3 holding
screws and carefully open the cover with the control panel.
Install an air duct with internal diameter of 100 mm in the wall or
ceiling. For wall installation make sure the duct runs to the outside with
a slight gradient. For ceiling installation you must insulate the air duct if
it passes through unheated areas.
The power cable should be sited with a spacing of X = 65 mm from the
centre of the air duct. You will need a switched „L1“ phase in addition
to the continuous „L“ phase for manual activation of the „boost ventila-
tion“
function.
Feed the power cable through the provided opening (A) and screw the
unit to the wall or ceiling with four screws. Ensure 2 positioning arrows
are pointing upwards when installing in wall application.
Strip the cable as shown in (B) and connect according to the circuit
diagram. The ventilator is double insulated and does not require a
protective earth conductor. If the house has an earth conductor, this
can be „parked“ at the terminal (C). Secure the connected cable with
the cord grip (D).
Then reclose the cover with the control panel and screw it down.
Attach a safety guard to the air duct outlet on the outside.
ENGLISH
GB
6

Chat with your Marley MP 100 S manual using AI

Get instant AI answers from your Marley MP 100 S manual

Ask anything about the Marley MP 100 S. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend MP 100 S?

Yes No

Frequently Asked Questions

A

It is used for continuous room ventilation, helping maintain fresh air in spaces like bathrooms and kitchens. It can also provide boost ventilation when extra airflow is needed.

Is this answer helpful?

A

Yes. It includes a humidity-based automatic function that can switch the fan on when moisture rises quickly in the room, reducing condensation and improving comfort.

Is this answer helpful?

A

No. The fan is double insulated, so a protective earth conductor is not required. If one is present in the installation, it can be parked at the terminal.

Is this answer helpful?

A

It can be mounted on a wall or ceiling and uses a 100 mm duct connection. Wall installation needs a slight outward slope, while ceiling installation may require duct insulation in unheated areas.

Is this answer helpful?

A

Its sound pressure ranges from 10 to 38 dB(A) at 3 meters, so it is designed to stay relatively quiet during normal operation.

Is this answer helpful?

A

Regular cleaning is simple. Wipe the cover and housing with a damp cloth and avoid aggressive cleaning agents to protect the surface and control panel.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Continuous base ventilation supports steady air renewal throughout the day.
  • Humidity automation helps the fan react to moisture spikes without manual input.
  • Low noise levels make it suitable for bathrooms and other quiet spaces.
  • Wall or ceiling installation offers flexible placement in different room layouts.
VS

Disadvantages

  • Manual boost mode requires a switched L1 phase, which may need extra wiring.
  • Installation must be done by qualified personnel and with power fully disconnected.
  • Airflow is designed for basic and medium-duty ventilation, not heavy extraction.
  • Settings and wiring may feel technical for users expecting a plug-and-play device.
M: OA-GPT-54-NAN

Product Specification

Operating Mode

Mains Operation (4W)

Color

white

Airflow

48.85 CFM

Noise Level

38dB(A)

Dimensions

7.83x5.12in (DxH)

M: OA-GPT-54-NAN

Product Description

Marley MP 100 S Built-in Fan: Smart, Quiet Ventilation for Modern Spaces

The Marley MP 100 S Built-in Fan is designed for continuous everyday ventilation, making it a practical choice for bathrooms, kitchens, and other rooms that need reliable air exchange. If you are looking for a compact solution that blends simple operation with useful automation, the Marley MP 100 S Built-in Fan Manual gives a clear picture of how this unit is meant to perform in real homes: quietly, efficiently, and with minimal fuss.

One of its biggest strengths is flexibility. The fan can run as a basic ventilation system all day, while also offering boost ventilation when extra airflow is needed. That boost mode can be triggered manually through a switched L1 phase or automatically with a humidity sensor. This means the fan can respond to sudden moisture changes, helping reduce condensation and supporting a healthier indoor climate.

Installation is straightforward for a built-in model, with support for wall or ceiling mounting and a standard 100 mm duct connection. The design includes double insulation, so no protective earth conductor is required, and the control panel allows the settings to be adjusted for different room types. Factory presets are available for smaller bathrooms and larger spaces, making initial setup easier.

Performance is balanced rather than aggressive. With airflow ranging from 10 to 83 m³/h, sound pressure as low as 10 dB(A), and power consumption between 1.1 and 4.1 W, the fan is built to work efficiently without becoming intrusive. It is also rated IP24, which adds peace of mind for use in humid environments when installed correctly.

Beyond the basics, the unit offers useful extras such as post-run timing and adjustable humidity automation. These features help the fan stay active only when needed, which can improve comfort and potentially save energy over time. Maintenance is simple too: a damp cloth is all that is needed for regular cleaning.

Notes

  • Best suited for continuous ventilation with occasional boost use.
  • Requires proper electrical installation by qualified personnel.
  • Check duct placement, airflow direction, and room conditions during setup.
  • Ideal for users who want a compact, low-noise fan with smart control options.