EN
Installation: (See gure A.)
Cleaning Instructions
Clean mouse with approved cleaning method and approved
disinfectant or soap and water.
Cleaning methods you can use
• You can wipe the product with a soft cloth that is non-abrasive like a
microber cloth, an impregnated wipe, a soft brush similar to a paint
brush in bristle stiffness or a sponge, but not a scourer of any sort.
Approved disinfectants you can use
• Chlorine based, up to 100,000 ppm bleach content
• Alcohol based
• Glutaraldehyde based
• Phenol based
• Formaldehyde based, up to 370,000 ppm formaldehyde content
• Oxidising, such as Hydrogen Peroxide, up to 30,000 ppm content
• Quaternary Ammonium, up to 20,000 ppm content
Restrictions
• Only clean using the cleaning methods and disinfectants described
under cleaning instructions in this manual.
• Please note that the product must not be immersed.
• Always follow the instructions provided by the cleaning product
manufacturer.
• Do not use petroleum based cleaning uids such as Acetone or
abrasive cleaning aids and products.
• Do not expose the product to temperatures above 70 °C .
• Do not use temperature or pressure sterilization.
.............................................................................
DE
Installation: (Siehe Abbildung A.)
Reinigungs- und Desinfektionshinweise
Reinigen Sie die Maus mit anwendbaren Reinigungsmethoden und
Desinfektionsmitteln, oder Wasser und Seife.
Anwendbare Reinigungsmethoden
• Sie können das Produkt mit Hilfe eines weichen, nicht scheuernden
Tuchs (z.B. Mikrofaser), einer sehr weichen Bürste, oder eines sehr
weichen Schwamms, in Kombination mit Wasser und Seife, bzw. eines
geeigneten Desinfektionsmittels vollständig abwischen.
Anwendbare Desinfektionsmittel
• Auf Chlorbasis; bis zu 100.000 ppm Bleichmittelgehalt
• Auf Alkoholbasis
• Auf Glutaraldehydbasis
• Auf Phenolbasis
• Auf Formaldehydbasis; bis zu 370.000 ppm
• Oxidationsmittel wie Wasserstoffperoxid; bis zu 30.000 ppm
• Quartär-Ammonium; bis zu 20.000 ppm
Einschränkungen
• Verwenden Sie zur Reinigung ausschließlich die in dieser
Betriebsanleitung aufgelisteten anwendbaren Reinigungsmethoden
und -Desinfektionsmittel.
• Bitte beachten Sie, dass das Produkt nicht untergetaucht werden darf.
• Folgen Sie stets den Anweisungen des jeweiligen
Reinigungsmittelherstellers.
• Verwenden Sie niemals Reinigungsmittel auf Erdölbasis (z.B. Aceton),
oder raue, grobe, bzw. scheuernde Reinigungsprodukte.
• Setzen Sie Ihr Man & Machine Produkt nicht Temperaturen über
70 °C aus.
• Verwenden Sie keine Heißluft-Sterilisation oder Dampfsterilisation.
.............................................................................
FR
Installation: (Voyez la gure A.)
Instructions de nettoyage et désinfection
Nettoyez la souris en utilisant une des méthodes de nettoyage
autorisées et avec un des désinfectants autorisés, ou avec de l’eau
et du savon.
Méthodes de nettoyage autorisées
• Vous pouvez essuyer le produit avec un chiffon doux non-abrasif, par
exemple en microbre, des lingettes imprégnées, une brosse souple
dont les poils ont une rigidité semblable à un pinceau ou une éponge,
mais n’utilisez aucune sorte de grattoir
Désinfectants autorisés
• A base de javel, jusqu’à 100.000 ppm
• A base d’alcool
• A base de glutaraldéhyde
• A base de phénol
• A base de formol, jusqu’à 370.000 ppm
• Oxydants, tel que l’hydrogène peroxydé, jusqu’à 30.000 ppm
• Ammonium quaternaire, jusqu’à 20.000 ppm
PS/2
USB
A
C Mouse
•
Operating Manual
•
Bedienungsanleitung
•
Mode d’emploi
•
Manual de usuario
•
Manual do usuário
•
Istruzioni d’uso
•
Gebruikshandleiding
•
Installation

Chat with your Man & Machine C Mouse manual using AI

Get instant AI answers from your Man & Machine C Mouse manual

Ask anything about the Man & Machine C Mouse. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend C Mouse?

Yes No

Frequently Asked Questions

A

No, you must never immerse the product in water or any liquid. Submersion will void the warranty and likely damage the internal electronics.

Is this answer helpful?

A

You can use chlorine-based (up to 100k ppm), alcohol, glutaraldehyde, phenol, formaldehyde (up to 370k ppm), hydrogen peroxide (up to 30k ppm), and quaternary ammonium (up to 20k ppm).

Is this answer helpful?

A

Yes, it comes with a one-year limited warranty covering defects in materials and workmanship when used according to instructions.

Is this answer helpful?

A

No, do not use petroleum-based cleaning fluids such as acetone. These substances can damage the casing and compromise the device integrity.

Is this answer helpful?

A

Contact your place of purchase or submit a Return Material Authorization (RMA) form on the manufacturer's website if bought directly from them.

Is this answer helpful?

A

Yes, do not expose the product to temperatures above 70°C. Also, avoid using heat or pressure sterilization methods entirely.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Compatible with a wide range of strong disinfectants including bleach and alcohol
  • Durable construction designed for frequent sanitization in clinical settings
  • Includes a comprehensive one-year limited warranty for peace of mind
  • Safe to clean with soft cloths and brushes without damaging the surface
  • Reliable performance suitable for high-demand professional environments
VS

Disadvantages

  • Cannot be submerged in water or liquids under any circumstances
  • Strict temperature limits prohibit exposure above 70 degrees Celsius
  • Requires specific cleaning agents; petroleum-based fluids are forbidden
  • No support for heat or pressure sterilization methods
  • Returns require a valid RMA number and prior disinfection proof
M: QW-35-FL

Product Specification

Suitability

both hands (left hand, right hand)

Keys

3 (total), 2 (main), 1 (top)

Scroll wheel

1x 2-way

Scanning

LED red/IR

Resolution

1000 dpi

Illumination

N/A

Connection

wired (5.9ft), USB-A 2.0

Power supply

USB

Dimensions (WxDxH)

2.24x1.42x3.94in

Approximate Volume

3.3cu in (approximate shape)

Weight

4.41oz

Features

thumb rest, IP65 certified

M: QW-35-FL

Product Description

Man & Machine C Mouse: Hygiene Meets Performance

The Man & Machine C Mouse washable is designed for environments where cleanliness and durability are paramount. Whether used in healthcare facilities, laboratories, or high-traffic office spaces, this mouse stands out by offering a robust solution that withstands rigorous cleaning protocols without compromising functionality. Its unique design allows users to maintain strict hygiene standards while enjoying the precision and comfort of a high-quality input device.

Built for Sanitation

Unlike standard computer peripherals, the Man & Machine C Mouse is engineered to be cleaned frequently. Users can safely wipe it down with approved disinfectants, including chlorine-based solutions up to 100,000 ppm, alcohol, glutaraldehyde, phenol, formaldehyde, hydrogen peroxide, and quaternary ammonium compounds. This versatility ensures that the device remains free from harmful pathogens after every use.

Safe Cleaning Practices

Proper maintenance is key to extending the lifespan of your equipment. The manufacturer recommends using soft, non-abrasive materials such as microfiber cloths, impregnated wipes, soft brushes, or sponges. It is crucial to avoid scourers, petroleum-based fluids like acetone, and abrasive aids that could damage the surface. Additionally, the product must never be immersed in water or exposed to temperatures exceeding 70°C. Sterilization methods involving heat or pressure are strictly prohibited to prevent internal damage.

Reliability and Support

Backed by a one-year limited warranty, the Man & Machine C Mouse offers peace of mind regarding defects in materials and workmanship. The warranty covers repairs or replacements for issues arising under normal use, provided the product has not been abused or altered. For returns, customers must obtain an RMA number and ensure the device is sanitized before shipping. This commitment to quality makes it an ideal choice for professionals who demand reliability in critical settings.

Important Notes

  • Always follow the specific instructions of your cleaning product manufacturer.
  • Do not expose the mouse to extreme heat or pressure sterilization.
  • Ensure the device is dry before connecting it to a computer.