Keor Multiplug Maintenance Schedule
If storage temperature exceeds +25°C, repeat the 8-hour battery charging procedure every two months instead of every three.
If the UPS is not used, recharge the internal battery every 2 to 3 months by connecting it to a grounded mains socket.
During warehousing, charge the battery for 8 hours every 3 months by connecting the UPS to the mains supply.
Free maintenance reminders
Timed to your purchase date. Always free, unsubscribe anytime.
Ask a Question
Do you recommend Keor Multiplug?
Yes NoFrequently Asked Questions
No, you should not connect laser printers to the backup outputs because they draw high current during startup, which can trip the UPS overload protection.
Is this answer helpful?
The backup time is approximately 10 minutes for a typical workstation, depending on the connected load and battery health.
Is this answer helpful?
No, the internal sealed lead-acid battery is not user-replaceable. Service must be performed by qualified personnel.
Is this answer helpful?
If the load exceeds 100%, the unit will shut down automatically after 5 minutes. If it exceeds 120%, it shuts down immediately after 5 seconds.
Is this answer helpful?
Yes, the Legrand Keor Multiplug has an autorestart function that powers connected loads automatically once mains power is restored.
Is this answer helpful?
If the UPS is not used, the battery should be recharged for 8 hours every 2 to 3 months to maintain its health.
Is this answer helpful?
Yes, the Keor Multiplug is designed for both residential and commercial environments, though it may cause minor radio interference in some cases.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Fast transfer time of 2 to 6 ms ensures seamless switching during power failures
- Includes a convenient USB charging port for smartphones and tablets
- Features both battery-backed and surge-only outlets for flexible device connection
- High efficiency up to 98% reduces energy consumption and heat generation
- Built-in automatic restart function restores power to loads when mains returns
Disadvantages
- Simulated sine wave output may not be suitable for all highly sensitive medical equipment
- Internal battery is not user-replaceable, requiring professional service for replacement
- Fixed non-detachable power cord limits placement flexibility near the outlet
- Backup time is limited to approximately 10 minutes for a typical workstation
- Requires strict adherence to installation height and ventilation clearance rules
Product Specification
Type
Power strip with integrated UPS
Classification
VI (Line-Interactive)
Voltage
170-290V
Input
1x Schuko/C13
Outputs
4x Schuko, 1x USB-A
Interfaces
N/A
Data line protection
N/A
Autonomy time
15 min (50%)
Dimensions (WxDxH)
7.5x3.5x11.6 in
Features
HID support, 2x surge protector sockets without support function (Schuko)
Product Description
Legrand Keor Multiplug UPS/USV: Reliable Power Protection for Your Digital Life
In today's digital age, unexpected power outages can lead to data loss, hardware damage, and significant downtime. The Legrand Keor Multiplug UPS/USV series offers a robust solution designed specifically for residential and commercial environments where reliable power continuity is essential. This uninterruptible power supply system acts as a critical shield for your computers, networking equipment, and other sensitive electronics against the unpredictable nature of mains electricity.
The Keor Multiplug comes in two primary capacity models, catering to different needs with 600 VA and 800 VA options. Both units feature a line-interactive topology that provides simulated sine wave output during battery operation, ensuring compatibility with a wide range of devices. The device includes a dedicated USB port for charging mobile gadgets, adding versatility to its function as a power management hub. Its design incorporates four backup outlets that switch to battery power within milliseconds of a mains failure, guaranteeing that your work continues without interruption. Additionally, it features two surge-protected outlets that remain active even when the unit is turned off, offering constant protection against voltage spikes from the grid.
Installation is straightforward, provided safety guidelines are strictly followed. The unit requires a grounded wall socket and should be placed in a well-ventilated area with temperatures between 0°C and 40°C. The internal sealed lead-acid battery is maintenance-free, eliminating the need for user intervention regarding electrolyte levels or water. However, regular maintenance involves ensuring the battery remains charged if the unit is stored for extended periods. The front panel features intuitive LED indicators and an audible alarm system to inform users about the current status, whether it is operating on mains power, running on battery, or detecting a fault such as overload or low battery.
Safety is paramount with the Legrand Keor Multiplug. The device includes built-in protections against overloads, short circuits, and overvoltage. It automatically shuts down to prevent damage if the load exceeds its capacity or if a short circuit occurs. Users must never attempt to open the casing, as this voids the warranty and poses severe electrical risks. Proper disposal of the unit at the end of its life cycle is crucial to comply with environmental regulations regarding electronic waste and hazardous batteries.
Important Notes
- Do not connect laser printers to the backup outputs due to high startup currents.
- Ensure the power cable length does not exceed 10 meters for optimal performance.
- Recharge the battery every 2 to 3 months if the unit is not in use.
- Keep a clearance of at least 20 cm behind the unit for ventilation.
Pros and Cons
Pros
- Fast transfer time of 2 to 6 ms ensures seamless switching during power failures.
- Includes a convenient USB charging port for smartphones and tablets.
- Features both battery-backed and surge-only outlets for flexible device connection.
- High efficiency up to 98% reduces energy consumption and heat generation.
- Built-in automatic restart function restores power to loads when mains returns.
Cons
- Simulated sine wave output may not be suitable for all highly sensitive medical equipment.
- Internal battery is not user-replaceable, requiring professional service for replacement.
- Fixed non-detachable power cord limits placement flexibility near the outlet.
- Backup time is limited to approximately 10 minutes for a typical workstation.
- Requires strict adherence to installation height and ventilation clearance rules.
Frequently Asked Questions
Q: Can I connect a laser printer to the Legrand Keor Multiplug? A: No, you should not connect laser printers to the backup outputs because they draw high current during startup, which can trip the UPS overload protection.
Q: How long does the battery last during an outage? A: The backup time is approximately 10 minutes for a typical workstation, depending on the connected load and battery health.
Q: Is the battery inside the unit replaceable by the user? A: No, the internal sealed lead-acid battery is not user-replaceable. Service must be performed by qualified personnel.
Q: What happens if the UPS detects an overload? A: If the load exceeds 100%, the unit will shut down automatically after 5 minutes. If it exceeds 120%, it shuts down immediately after 5 seconds.
Q: Does the unit have an auto-restart feature? A: Yes, the Legrand Keor Multiplug has an autorestart function that powers connected loads automatically once mains power is restored.
Q: How often should I charge the battery if not in use? A: If the UPS is not used, the battery should be recharged for 8 hours every 2 to 3 months to maintain its health.