The high voltage cable in laid in the engine compartment in such a way as to allow the contact plates to be installed at the appropriate locations. To prevent
contamination, we recommend the upper half of the engine compartment. Always x the contact plates with the insulating base
downwards, avoid contact of the high voltage plates with other live parts, as well as with the ground wire. In order to connect a contact plate, thread this
onto the high voltage cable. There is only one drilled hole in the socket that will t this cable. Then carefully turn the supplied screw in the contact plate to
establish the electrical contact.
4. ELECTRICAL CONNECTION
Minus: Connect the cable with the screw eye to the minus or ground.
Plus: Connect the cable with the fuse to the steady plus (after the fuse box).
Control cable (Clip 15): The remaining cable is the control cable. This is connected to the ignition-switched plus and ensures that the device is switched o
when the vehicle is switched on. If you do not connect this cable, the device is permanently in operation. This will work, but it is not permitted!
Information: This product is maintenance-free, but the high voltage may be interrupted by contamination of the contact plates.
LED is o – Remedy: Switch the device o, wait around 5 minutes, clean the plates, attach anew.
We accept no liability for unprofessional installation or use.
Without marten repelling products, no harm will come to the animals!
Please keep the product away from children!
Please also note the additional products in the marten repellent range:
Protective conduit article number: 16263, 16270
Odor hanger article number: 16264
Pre-cleaner article number: 16265
Defensive spray article number: 16266
Further ultrasound devices article number: 16260, 16261, 16269
5. NOTES REGARDING ENVIRONMENTAL PROTECTION
Do not dispose of electrical devices with the household waste! Electrical and electronic scrap must be collected separately and disposed of in
an environmentally responsible manner for recycling. Please contact your community or city administration regarding disposal options for
electrical and electronic scrap.
6. CONTACT INFORMATION
EAL GmbH
Otto-Hausmann-Ring 107
42115 Wuppertal
Germany
+49 (0)202 42 92 83 0
+49 (0) 202 42 92 83 – 160
info@eal-vertrieb.com
www.eal-vertrieb.com

Chat with your LAS 16262 manual using AI

Get instant AI answers from your LAS 16262 manual

Ask anything about the LAS 16262. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend 16262?

Yes No

Frequently Asked Questions

A

It combines two deterrents. First, it emits pulsed ultrasound in the region of 23 kHz that martens perceive similarly to fear and warning sounds. Second, six high-voltage contact plates can deliver a safe but forceful electric shock if an animal makes contact. Together, the sound and the contact deterrent increase the chance that martens avoid the area.

Is this answer helpful?

A

The device is designed for a 12 V vehicle supply. Internally, it generates a high voltage in the range of 250 to 350 V. Typical power consumption is about 19 mA +/- 15%, with a recommended fuse rating of 500 mA / 250 V.

Is this answer helpful?

A

Mount it in the engine compartment so the ultrasound can spread freely, similar to a torch light cone. Ideally, position it from top to bottom to reduce effects from dirt and water. Even with splash-water protection, choose a dry location and keep it away from hot parts like the exhaust or engine block.

Is this answer helpful?

A

The red LED is used as a functional check for the ultrasound output. The yellow LED indicates the high-voltage function. The unit also uses function checking via LEDs, helping you determine whether the system is working after installation.

Is this answer helpful?

A

It is described as maintenance-free, but you may need to clean the contact plates if they become dirty. Contamination can cause the high voltage to drop or stop working. If an LED indicates trouble, switch the device off, wait about 5 minutes for voltage to dissipate, then clean or re-secure the plates.

Is this answer helpful?

A

The Clip 15 control line connects to ignition-switched plus and ensures the device switches off when the vehicle is in operation. If you do not connect this cable, the device runs continuously, which is stated to be not permitted. Connecting it helps align operation with vehicle use.

Is this answer helpful?

A

Before jump starting, bridging, or quick charging, switch the device off or remove the fuse in the plus cable for overvoltage protection. This precaution helps prevent damage that can occur from electrical surges during high-load charging events.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Dual deterrent system using pulsed ultrasound and high-voltage contact plates
  • LED indicators help verify ultrasound and high-voltage operation quickly
  • Designed for 12 V vehicle systems while generating 250-350 V internal high voltage
  • Wide effective ultrasound reflection angle of 160 degrees
  • Clip 15 control cable support helps switch off when the vehicle is in use
VS

Disadvantages

  • Performance depends on careful installation and correct wiring
  • Contamination of the contact plates can interrupt high voltage
  • Needs mounting in a dry spot and away from hot engine components
  • Do not expose to steam cleaners or pressure washers
  • Overvoltage precautions are required during jump starting and quick charging
M: OA-GPT-54-NAN

Product Specification

Type

High-voltage device, Ultrasound device

Operating voltage

12 V

Power consumption

19 mA

Sound pressure

100 dB

Frequency range

23 kHz

Beam angle

160 °

Contact plates

6

Special features

CAN-Bus compatible

M: GO-GEM-FL-25

Product Description

LAS Marten Repellent Device High Voltage & Ultrasound (16262)

If you want a tougher approach to protecting your vehicle against martens, the LAS Marten Repellent Device High Voltage & Ultrasound combines two deterrents in one compact system. Built for installation in the engine compartment, it uses high-frequency pulsed ultrasound alongside a safe-but-effective high-voltage contact shock through dedicated contact plates. For proper setup and wiring details, use the LAS Marten Repellent Device High Voltage & Ultrasound Manual.

The ultrasound component generates pulsing tones around 23 kHz, designed to match the sound range that martens respond to as fear and warning signals. To support reliability, the unit also includes LED indicators: the red LED helps you verify ultrasound function, while the yellow LED is associated with the high-voltage system. Together with the dual LED function check, you can quickly confirm whether the device is operating as intended.

A key strength is the high-voltage element. The device operates from a 12 V vehicle supply and produces an internal high voltage in the range of 250 to 350 V. Six high-voltage contact plates deliver the deterrent action when a marten approaches and contacts the mounted plates. The unit is engineered with a broad effective ultrasound reflection angle of 160 degrees, helping distribute the deterrent sound more evenly in the compartment.

In practice, installation is straightforward but must be done carefully. Before mounting, the engine bay should be thoroughly cleaned (or prepared using the recommended pre-cleaner). The contact plates must be secured with the insulating base facing downward, positioned to avoid accidental contact with other live parts or ground. Mount the device so the sound can travel freely, ideally with a top-to-bottom orientation to reduce contamination from dirt and water.

Key takeaways

  • Uses pulsed ultrasound (23 kHz) that targets martens' fear and warning signal range
  • Adds a high-voltage contact deterrent via six mounted contact plates
  • Includes LED checks for ultrasound and high-voltage operation
  • Runs from 12 V vehicle power while generating 250-350 V internal high voltage
  • Installation quality matters: dirty contact plates can interrupt high voltage

Pros

  • Dual deterrent approach: ultrasound plus high-voltage contact plates
  • Clear operational feedback via LED function monitoring
  • Engine-bay friendly design with splash-water protection considerations
  • Control line support helps switch off when ignition is on (Clip 15)
  • Broad ultrasound effectiveness with a 160-degree reflection angle

Cons

  • Requires correct wiring, including the Clip 15 control connection
  • High voltage can drop if contact plates become contaminated
  • Must be installed in a dry location and kept away from hot components
  • Do not clean with steam or pressure washers on the device
  • Improper installation voids liability and can affect performance