7.2.1 Placing
The balance must be installed in a way that the weighing plate is exactly in horizontal
position.
7.2.2 Levelling (FOB and FOB-LM models only)
Level balance with foot screws until the air bubble of the water balance is in the
prescribed circle.
Check levelling regularly.
7.2.3 Scope of delivery
Serial accessories:
• Balance
• Weighing pan
• Mains adapter (option KERN FOB-A01, all models except models FOB)
• Mains adapter (standard, FOB models only)
• Battery (all models except FOB models)
• Rechargeable battery (standard, FOB models only)
• Protective cover
• Operating manual
7.3 Mains connection
The balance may be operated via the optional mains adapter. The stated voltage
value must be the same as the local voltage. Only use original KERN mains
adapters. Using other makes requires consent by KERN.
Illustration example KERN FOB-LM
Illustration example KERN FOB

Chat with your Kern FOB manual using AI

Get instant AI answers from your Kern FOB manual

Ask anything about the Kern FOB. Answers come from this manual, with the pages they are based on.

FOB Maintenance Schedule

Remind me when maintenance is due
Yearly
Check calibration weights and scale accuracy

In quality assurance, measurement properties of the scale and any test weight must be checked at regular intervals. The user defines the interval.

Show in the manual (page 19)
As needed
Clean stainless steel parts

Use a soft cloth with suitable stainless steel cleaner. Do not use metal brushes or cleaners containing alkalis or acids.

Show in the manual (page 45)
Immediately
Remove spilled material

Remove spilled weighing goods immediately to prevent damage or contamination.

Show in the manual (page 45)
Every relocation
Re-level the scale

Regularly check leveling. Re-level using foot screws until the bubble is in the required circle after moving the device.

Show in the manual (page 21)
Periodically
Calibrate the scale

Calibrate periodically during operation for accurate measurements, especially after location changes or temperature fluctuations.

Show in the manual (page 24)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend FOB?

Yes No

Frequently Asked Questions

A

To calibrate, turn off the device, then press and hold the ON/OFF button while pressing the UNIT button three times. Release the buttons when a number appears. Press TARE to zero, place the recommended calibration weight in the center, and press TARE again until CAL displays. Remove the weight and the scale will return to weighing mode.

Is this answer helpful?

A

While the scales have IP65 or IP67 protection against dust and water, they should not be used in extreme weather. Avoid direct sunlight, rain, and significant temperature fluctuations to maintain accuracy and prevent damage to the internal components.

Is this answer helpful?

A

When the battery charge is depleted, the display will show LobAt. The scale will automatically shut down 30 seconds later. You must replace the batteries immediately or connect the AC adapter to continue using the device.

Is this answer helpful?

A

Only specific models, such as the FOB-LM series, are certified for legal trade (eichpflichtig). These models require official verification by a metrology office before being used for commercial transactions where price is determined by weight.

Is this answer helpful?

A

You can switch units by pressing the UNIT button in weighing mode. Alternatively, enter the menu by holding the TARE button, navigate to Unit settings, select your desired unit, and confirm with the TARE button.

Is this answer helpful?

A

The Hold function captures a stable average weight reading, which is useful for weighing unstable or moving objects. Press the HOLD button to activate it; the scale will blink until the value stabilizes, then lock the reading on the display.

Is this answer helpful?

A

Clean the scale regularly to remove spills and dust. Always disconnect power first. Use a soft cloth dampened with a mild stainless steel cleaner. Avoid abrasive materials or harsh chemicals like bleach or acid-based products.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • High-precision measurement with excellent reproducibility
  • Durable stainless steel construction resistant to corrosion
  • Multiple unit conversion options for international use
  • Backlit display for visibility in dim lighting
  • Flexible power options with battery and mains support
VS

Disadvantages

  • Requires periodic calibration after moving locations
  • Manual leveling needed for some models to ensure accuracy
  • Battery replacement required periodically for portable use
  • No wireless connectivity for data transfer in standard models
  • Strict environmental limits regarding temperature and humidity
M: QW-35-FL

Product Specification

Type

Bench scale

Material

Stainless steel

Units of measurement

g/oz/dwt/ozt/gn/lb

Power supply

Mains operation

Features

LCD, automatic shut-off

Dimensions

9.45x7.09x2.36 in

Weight

4.41 lb

M: QW-35-FL

Product Description

Discover the Precision of Kern FOB Stainless Steel Scales

The Kern FOB series represents a pinnacle in precision weighing technology, designed for professionals who demand accuracy and durability in their daily operations. Crafted with high-quality stainless steel, these scales are built to withstand demanding environments while delivering consistent, reliable results. Whether you are working in a laboratory, a kitchen, or an industrial setting, the Kern FOB offers a robust solution for all your weighing needs.

These devices feature a sleek, modern design that integrates seamlessly into any workspace. The stainless steel construction ensures resistance to corrosion and easy cleaning, making them ideal for hygiene-sensitive applications. Users can choose from various models tailored to specific weight ranges, from small-scale precision tasks to heavier industrial loads. Each unit is equipped with an intuitive interface, allowing for quick setup and operation without extensive training.

The versatility of the Kern FOB extends beyond simple weighing. Advanced features such as automatic tare functions, multiple unit conversions, and hold modes provide enhanced functionality for complex tasks. The backlit display ensures readability in low-light conditions, while the auto-off function helps conserve battery life during periods of inactivity. For users requiring strict compliance, certain models come certified for legal trade, ensuring accuracy in commercial transactions.

Installation is straightforward, with clear instructions guiding users through leveling and calibration processes. The inclusion of a stable base and adjustable feet guarantees a flat surface for precise measurements. Additionally, the option for both battery and mains power operation provides flexibility for use in locations without immediate access to electrical outlets. With a focus on user safety and long-term reliability, the Kern FOB stands out as a top choice for anyone seeking professional-grade weighing equipment.

Notes:

  • Ensure the scale is placed on a stable, vibration-free surface.
  • Regular calibration is recommended for maintaining accuracy.
  • Clean only with soft cloths and mild stainless steel cleaners.