kW. WARNING: Accessible parts may become very hot. Keep out of reach of children and away from other appliances.
The appliance should be operate away from flammable materials and at a minimum distance of 70 cm from furniture, walls and ceilings.
Possible exhalation produced by combustion or by materials being worked on, can be dangerous. Always require information about
the possible toxicity. Use, if necessary, protective glasses. Check that seals (between the appliance and the gas container) are in
place and in good condition before connecting to the gas container. Do not use the appliance if it has damaged or worn seals; Do not
use an appliance which is leaking, damaged or which does not operate properly; If there is a leak on your appliance (smell of gas),
take it outside immediately into a well ventilated flame free location where the leak may be detected and stopped. If you wish to check
for leaks on your appliance do it outside. Do not try to detect leaks using a flame, use soapy water (revelgas cod. 1726). Apply solution
of soap and water or gas detector in the interspaces of the unit. If bubbles appear, it means that there is a leak and it must be repaired
before use. If you detect a leak and you cannot repair it, don’t try to fix it another way, but contact the customer service.
Do not modify the appliance. It 's dangerous to bring modification on device, remove or disassemble its components or use
components which are not approved by the manufacturer, all of this causes the cancellation of warranty and manufacturer's
responsibility. Never throw an empty cartridge into fire.
USE
Carefully read the information printed on the cartridge for use before introducing it in the housing. Warning : cartridge is supplied
only with items KE2018SETS – KE2019SETS – 820AKIT460.
The cartridge must be mounted or shall be changes in a ventilated location, preferentially outside, away from any sources
of ignition, such as naked flames, pilots, electric fires and away from other people. Smoking is prohibited during assembling
operation and all operations of the unit.
MOD. KE2018 – KE2019 – 770 – 775
The appliance does not require preheating. The appliance must operate in horizontal surface or with a maximum inclination
of 10-20 ° in order to avoid a dangerous lengthening of flame caused by burning of cartridge’s fuel in liquid phase.
MOD. KE2018A – KE2019A– 770A -775A
The appliance is designed to work in a horizontal position and with any inclination (360°) after a warm up for 20-30 seconds.
For long use it is recommended a maximum inclination of 60° of the device, to avoid excessive heating by refraction.
Gas cartridge assembly
This appliance shall only be used with piercing gas cartridge at direct pressure butane mod. Kemper 1120S1/S2, Plein Air PL707,
Kemper 1120 (only extre CEE) and Plein Air PL880 (only extra CEE) . It may be hazardous to attempt to fit other types of gas
containers.
1. Make sure the gas supply tap knob D is in the closed position that is clockwise rotated toward the sign «-» (Fig. 5).
2. Separate completely the base B from the top A by unscrewing it on clockwise direction (fig. 1).
3. Remove the top.
4. Remove the cartridge holder spring (fig.2).
5. Insert the cartridge in the base (fig. 3) and lock it with the cartridge holder spring (fig. 4).
6. Make sure the rubber seal of the tap C is in regular position (Fig. 5) and that it is not damaged.
Do not use the appliance if the
gasket C is damaged or ruined.
7. Screw the base to the top side by turning it counterclockwise until it stops, holding it in stable and horizontal position (Fig. 6).
When replacing the cartridge repeat from step 1 after making sure that the gas cartridge is completely empty (shake to hear the noise
made by the liquid) .
The cartridge is currently perforated; when opening the valve, if there is no gas release, the cartridge should absolutely not be removed
as the cartridge is anyway punctured. In this case, contact your retailer.
MOD. 1040A – 1045A
The appliance is designed to work in a horizontal position and with any inclination (360°) after a warm up for 20-30 seconds.
For long use it is recommended a maximum inclination of 60° of the device, to avoid excessive heating by refraction.
Gas cartridge assembly
This appliance shall only be used with piercing gas cartridge at direct pressure butane mod. Kemper 1120S1/S2, Plein Air
PL707,Kemper 1120 (only extra CEE) and Plein Air PL880 (only extra CEE) and with threaded valve gas cartridge at direct pressure
butane/propane mixture mod. Kemper 1121F. It may be hazardous to attempt to fit other types of gas containers.
1. Make sure the gas supply tap knob D is in the closed position that is clockwise rotated toward the sign «-» (fig. 9).
2. Separate completely the colored base A from the top by unscrewing it on clockwise direction (fig. 7).
3. Insert the cartridge B in the colored base and
make sure that it is not damaged and is accommodated in the appropriate seat
(fig. 8).
4. Make sure the rubber seal C of the tap is in regular position (Fig. 9) and that it is not damaged. Do not use the appliance if the
gasket C is damaged or ruined.
5. Screw the colored base A to the top side by turning it counterclockwise until it stops, holding it in stable and horizontal position
(Fig. 10).
6. When replacing the cartridge repeat from step 1 after making sure that the gas cartridge is completely empty.
The cartridge is currently perforated; when opening the valve, if there is no gas release, the cartridge should absolutely not be removed
as the cartridge is anyway punctured. In this case, contact your retailer.
MOD. 820A – 825A
The device is designed to work in a horizontal position and with any inclination (360°) after a warm up for 20-30 seconds.
For long use it is recommended a maximum inclination of 60° of the device, to avoid excessive heating by refraction
.
Gas cartridge assembly
This device works only with threaded valve gas cartridge at direct pressure mixture butane/propane mod. Kemper 1121F, 575, 580
and 1126F46. It can be dangerous to try to use other gas cartridges.
1. Make sure the gas supply tap knob D is in the closed position that is clockwise rotated toward the sign «-» (fig. 11).
2. Make sure the rubber seal C of the tap is in regular position (Fig. 11) and that it is not damaged. Do not use the appliance if
the gasket C is damaged or ruined.

Chat with your Kemper 770 manual using AI

Get instant AI answers from your Kemper 770 manual

Ask anything about the Kemper 770. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend 770?

Yes No

Frequently Asked Questions

A

It is intended for brazing, soldering tin, aluminum, and silver, light forging, bending bars, sheets, and tubes, paint stripping, and thawing. Select the task carefully and follow material-specific safety requirements.

Is this answer helpful?

A

No. The standard Kemper 770 model does not require preheating. It should be used horizontally or with a maximum inclination of about 10 to 20 degrees to avoid an unusually long flame.

Is this answer helpful?

A

The 770 is specified for direct-pressure piercing butane cartridges such as Kemper 1120S1/S2 and Plein Air PL707. Some regions may also permit Kemper 1120 or Plein Air PL880. Do not adapt other cartridge types.

Is this answer helpful?

A

Close inspection and cartridge installation should be completed first. Open the gas valve slightly toward the plus symbol, then fully press the piezo ignition button. If it does not light, repeat the procedure.

Is this answer helpful?

A

Take the unit outdoors to a well-ventilated area without ignition sources. Apply soapy water to connection areas and watch for bubbles. Never use a flame to locate a leak. Do not use the torch until the leak is repaired.

Is this answer helpful?

A

Clean the body with warm soapy water and a soft cloth or cotton pad. Use a soft brush for the burner and avoid abrasive products. Store the cooled torch upright in a well-ventilated location away from children.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Piezo ignition on the 770 model supports quick lighting without a separate match or lighter.
  • Suitable for soldering, brazing, paint stripping, thawing, bending, and light forging tasks.
  • Adjustable gas control lets users raise or lower flame output for the job at hand.
  • No preheating is required for the standard 770 model when used within its recommended angle.
VS

Disadvantages

  • The standard 770 must remain horizontal or within about 10 to 20 degrees of tilt during operation.
  • It only accepts specified direct-pressure piercing butane cartridges.
  • Piercing cartridges cannot be removed once punctured unless they are completely empty.
  • Safe use requires ventilation, distance from flammables, and regular seal inspections.
M: gpt-5.6-terra

Product Specification

Gas consumption

0.26 lb/h

M: gpt-5.6-terra

Product Description

Kemper 770 Blowtorch - Read, Download & Print Free

The Kemper 770 Blowtorch is a portable gas-fired tool designed for practical heating and joining tasks in workshops, garages, and well-ventilated work areas. Built for controlled flame work, it is suitable for brazing, soldering tin, aluminum, and silver, as well as light forging, bending metal bars or tubing, paint stripping, and thawing. Its versatile purpose makes it useful for users who need concentrated heat without relying on a large stationary system.

Designed for Direct Butane Cartridges

The Kemper 770 Blowtorch is intended for use with specified direct-pressure piercing butane cartridges, including Kemper 1120S1/S2 and Plein Air PL707 models. Using only compatible cartridges is important for correct fit, reliable operation, and safe gas handling. The cartridge is installed with the gas valve closed and the seal checked for proper condition before the unit is assembled.

The 770 model is a piezo-ignition version. To light it, the gas valve is opened slightly toward the plus symbol and the ignition button is pressed. Flame output can then be adjusted through the control knob, allowing the user to increase heat for demanding work or reduce it for more measured applications.

Working Position and Everyday Use

Unlike the 770A version, the standard Kemper 770 Blowtorch does not require preheating. It should be operated horizontally or at a limited angle of approximately 10 to 20 degrees. This operating position helps prevent an excessively long flame caused by liquid fuel entering the burner.

A clean, stable work area is essential. The torch should be kept at least 70 cm from furniture, walls, ceilings, and flammable materials. Good ventilation is also necessary because combustion and heated work materials may create potentially harmful fumes. Protective eyewear is recommended whenever the task or material calls for it.

Care and Safety Notes

Before each use, inspect the rubber seal between the torch and cartridge. Never operate the unit if it is leaking, damaged, or not working correctly. If gas is smelled, move the tool outdoors to a well-ventilated, ignition-free place. Check suspected leaks with soapy water, never with a flame.

For routine care, clean the body with warm soapy water and avoid abrasive cleaners. A soft brush can be used for the burner. Store the blowtorch upright in a ventilated location, away from children. Cartridges are disposable, must not be refilled, and should never be thrown into fire.

Notes

  • Fit only approved cartridges and replace them outdoors or in a highly ventilated area.
  • Allow the burner to cool fully before changing cartridges or storing the tool.
  • Do not modify the blowtorch or use unapproved replacement parts.