581f6ba50ac09847600b3dce3bafc8e7f161 page 1
ADO.UG.140612
PERFORM BETTER. PACK LESS.
Thanks for choosing the SteriPEN®
Adventurer Opti and congratulations
on your purchase.
Adventurer Opti is built to be safe, simple
and straightforward. If, after reading this
guide, you have any questions please
don’t hesitate to call us at 1-888-826-6234.
We love hearing from you.
Also, be sure to visit us online and register
your Adventurer Opti for all the latest
news and special deals.
Thanks again and happy travels
from your friends at SteriPEN.
P.S. Don’t forget to recycle the packaging.
EASY TO USE BATTERY GUIDE
Water sensor will flash.
When lamp turns off, LED indicator will display
treatment success or failure (see “Adventurer Opti
LED Indicator Guide section”).
After purifying, be sure to wipe bottle
threads dry before drinking.
Water sensor will flash.
When lamp turns off, LED indicator will display
treatment success or failure (see “Adventurer Opti
LED Indicator Guide section”).
After purifying, be sure to wipe bottle
threads dry before drinking.
ADVENTURER OPTI’S ANATOMY
CARE & CLEANING
While Adventurer Opti’s battery compartment is
designed to be highly water-resistant, it is not
waterproof. Avoid submerging Adventurer Opti’s
battery compartment end in water.
Adventurer Opti’s performance may be adversely
affected by cold weather. In temperatures below
32ºF/0ºC carry the unit close to your body or warm
up batteries before use. If batteries are too cold,
Adventurer Opti’s LED indicator may give low
battery signal. Warm up batteries and treat again.
Make sure to wipe dry after each use.
When not in use, Adventurer Opti should be kept in
a safe place that is clean and dry. It should not be
exposed to temperatures above 120°F/49°C or below
-4°F/-20°C. Also, when storing Adventurer Opti
for prolonged periods, remove batteries to avoid
draining them while not in use.
To clean Adventurer Opti, wash with a soft cloth
and a mild soap solution. Rinse soap from device
and dry with a clean, soft cloth.
If Adventurer Opti’s bulb is cracked, chipped or
damaged, don’t use it. Return it to the store or
contact us for repair. Email us at [email protected]
or call us at 1-888-826-6234 for help. Do not try to
fix it yourself.
Adventurer Opti runs on lithium disposable
CR123 or rechargeable RCR123 batteries.
For best results, always use quality,
name brand batteries.
To avoid battery performance being affected
by cold weather, carry them close to your body
to keep them warm.
1 Lamp cover
2 UV lamp
3 Optical water sensor
4 Activation button
5 Indicator LED
6 Battery compartment cap
7 Battery compartment screw
SPECIFICATIONS
Treatment size: 0.5 or 1 liter
Treatment time: 48 or 90 seconds
Lamp life: 8,000 activations
Treatments per set of batteries:
up to 50 (30 with rechargeables)
Minimum bottle opening: 38mm
Weight: 103g (including batteries)
Size: 155 x 40 x 24mm
FLASHLIGHT
Turn on/off flashlight
by holding down
activation button for
3 seconds. Flashlight
will turn off automatically
after 3 minutes.
STEP 1
Remove lamp cover.
Pull straight off and away
from the lamp.
STEP 3
Submerge and stir.
Ensure blinking water sensor is
immersed. UV lamp will illuminate.
STEP 2
Press activation button.
1x for 1 liter treatment,
2x for 0.5 liter treatment.
STEP 2
Install two CR123
batteries with
polarities as shown.
STEP 1
Loosen battery
compartment screw to
open battery compartment.
STEP 3
Tighten coin screw on
end cap until snug.
Do not overtighten.
3
1
2
4
5
6
7
Hydro-Photon, Inc.
PO Box 675
262 Ellsworth Road
Blue Hill, ME 04614 USA
Toll Free USA: 1-888-SteriPEN
(+1) 207-374-5800
www.steripen.com
© 2014 Hydro-Photon, Inc.
ADVENTURER
Opti
www.steripen.com
facebook.com/steripen
@steripen
LED INDICATORS
Successful water treatment,
batteries low (1L)
Successful water treatment,
batteries low (½L)
Ready for treatment
SUCCESSFUL
PRE-TREATMENT (repeating sequences)
POST-TREATMENT (repeating sequences)
Not submerged in water in time
Successful water treatment (1L)
Successful water treatment (½L)
Check, replace, or recharge batteries
Replace or recharge batteries
Water not detected
Successful water treatment, UV lamp
good for less than 100 uses (1L)
Successful water treatment, UV lamp
good for less than 100 uses (½L)
Replace UV lamp, UV lamp damaged
UNSUCCESSFUL
If LED indicators show normal signals, but the lamp does not illuminate,
do not consume. Contact SteriPEN® support.
User’s Guide

Chat with your Katadyn SteriPEN manual using AI

Get instant AI answers from your Katadyn SteriPEN manual

Ask anything about the Katadyn SteriPEN. Answers come from this manual, with the pages they are based on.

SteriPEN Maintenance Schedule

Remind me when maintenance is due
Every 8,000 activations
Replace UV lamp

When the bulb reaches 8,000 activations, the LED will flash red three times then green once; contact support for replacement.

After every use
Wipe device dry

Make sure to wipe Adventurer Opti dry after each use and keep it in a clean, dry place when not in use.

After every use
Clean with mild soap

To clean the device, wash with a soft cloth and mild soap solution, rinse thoroughly, and dry with a clean soft cloth.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend SteriPEN?

Yes No

Frequently Asked Questions

A

No, the ultraviolet light targets microorganisms like bacteria and viruses. It does not filter out dissolved solids, heavy metals, or chemicals. Pre-filtration is recommended for water with high sediment content.

Is this answer helpful?

A

A single full charge supports approximately twenty one liter treatments. If you carry spare batteries or have a USB charger, you can continue indefinitely between charges.

Is this answer helpful?

A

Yes, it comes with a Micro USB Dust Cover for protection. However, do not submerge the charging port itself while the cover is off. Clean connections carefully.

Is this answer helpful?

A

No, it is designed for fresh water purification only. Saltwater conductance differs and may damage the sensor pins or prevent proper activation cycles entirely.

Is this answer helpful?

A

The indicator lights will show a red sequence indicating failure or expiry. The lamp cannot be replaced by users. Contact support for replacement units under warranty.

Is this answer helpful?

A

Submerging takes two seconds for sensor lock plus sixty seconds for the main cycle. Total time is roughly sixty-two seconds per liter of water.

Is this answer helpful?

A

Yes, the beam is contained within the device housing. Direct exposure to UV light is harmful so never aim it at skin or eyes during operation.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • USB rechargeability allows diverse power options like solar panels or laptops easily
  • Green LED indicators provide clear visual feedback on treatment status quickly
  • Chemical free purification maintains natural water taste without negative side effects
  • Treats water in approximately sixty seconds for most containers effectively
  • Durable design with three year limited warranty protects long term investment
VS

Disadvantages

  • UV lamp lifespan is limited to approximately one hundred uses maximum total
  • Requires clear water for sensor activation which may need pre-filtering muddy sources
  • Battery depletes faster if water temperature is extremely cold affecting duration
  • Sensitive electronic components require careful handling away from moisture ports
  • Initial cost is higher compared to basic iodine tablets or boiling methods available
M: QW-35-FL

Product Specification

Type

Water Filtration

M: QW-35-FL

Product Description

Secure Hydration For Every Outdoor Journey With The Katadyn Steripen

When exploring remote locations, finding safe drinking water is a primary concern. The Katadyn Steripen Trinkwasserentkeimer Manual serves as an essential guide for utilizing this advanced water purification device. It represents a significant upgrade for hikers and campers seeking chemical-free solutions. This handheld unit destroys bacteria and viruses using ultraviolet light, ensuring that lakes or streams become safe for consumption without altering taste or smell.

How The Purification Works Effectively

Using this equipment is straightforward yet requires specific attention to detail. Place the lamp directly into the water volume you intend to treat. Submerge the metal water sensor pins to activate the mechanism. If water is murky, sensors may not function correctly. After two seconds underwater, the green LED indicator flashes rapidly. This signal confirms the UV lamp is active. Gently stir the water to guarantee uniform treatment exposure throughout the liquid being purified completely.

Recharging And Battery Life Details

Power management is simplified through modern connectivity standards. The device features USB rechargeability which allows users to connect to solar panels, wall outlets, or computers via micro USB cable. A fully charged battery supports approximately twenty treatments per cycle. This means you can treat roughly twenty liters before needing to power up again. Specifications list voltage at five volts with a two point five watt load requirement for stable current delivery.

Safety And Longevity Considerations

Regular maintenance ensures peak performance over time. Protecting your eyes and skin from direct UV exposure is mandatory. Do not use the lamp as a general light source. The UV lamp remains good for less than one hundred uses. Monitoring the serial number helps track warranty eligibility under the three year limited warranty terms provided for customer peace of mind. Warning signs indicate when batteries are low or if the sensor detects completion. Always read the instruction manual thoroughly before first use to avoid damaging the unit.

Maintenance tips include storing the dust cover over the port when not in use. Never bypass the water sensor as it prevents activation. Keep contacts dry to prevent corrosion. By adhering to safety protocols regarding wet hands, you maximize efficiency while minimizing risks associated with improper handling of electrical components outdoors effectively.