Manual.ly Logo

Inqua BR021000 Manual

4.9 · 28 Ratings

PDF manual · 186 Pages

English

M: qwen/qwen3.5-flash-20260224
page

/ 186

Loading...
ad336f7aac3414cea210ba0c4bb71382a1eb page 1d
29
en
GENERAL
Manufacturer's
data
See back of instructions for use.
Notes on the
instructions for
use
Purpose of the instructions for use
These instructions for use describe how the INQUA
®
Inhalator is
assembled, how it works, and how it should be used. They are
intended to ensure that the individual components can be used in
complete safety.
These instructions for use do not include information on using the
nebuliser that is to be attached to the compressor, nor for the masks.
Please read the instructions for use of the nebuliser which accom-
pany that item.
Forms of emphasis
The following forms of emphasis are used in these instructions for
use to indicate important parts of the text:
 The arrow indicates that a given action must be taken.
Representation of hazard warnings
In these instructions for use, hazard warnings are indicated by a
warning triangle and a signal word. The following signal words are
used depending on the nature and degree of danger being
described.
NOTICE
Indicates general precautionary measures which are to be
observed to avoid damaging the product during use.
CAUTION
Indicates a hazard that may cause mild to moderate injury or
damage if it is not avoided.
WARNING
Indicates a hazard that may cause serious injury or death if it is
not avoided.
Note on storing the instructions for use
These instructions for use must be stored so that anyone who is
using the INQUA
®
Inhalator can access them whenever necessary.
They are an integral part of the product and must be included with
the device if the INQUA
®
Inhalator changes hands (e.g. is sold).
Read these instructions for use carefully and completely before
using for the first time. Do not use the INQUA
®
Inhalator unless
you fully understand the contents of these instructions for use.
If symptoms persist or if your condition worsens, discontinue the
application and contact your doctor immediately.

Chat with your Inqua BR021000 manual using AI

Get instant AI answers from your Inqua BR021000 manual

Ask anything about the Inqua BR021000. Answers come from this manual, with the pages they are based on.

BR021000 Maintenance Schedule

Remind me when maintenance is due
Yearly
Inspect compressor for replacement

If the compressor is still in use after four years of operation, contact INQUA or a local partner to have the device tested.

Show in the manual (page 22)
Every 200 hours
Replace air filter

Change the air filter after every 200 operating hours. Replace it at least once a year or if visibly dirty, discolored, or damp.

Show in the manual (page 22)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend BR021000?

Yes No
0
User Pic

Sandra Klein

7 months ago

Does the inhalator include a mask for young children and is it too loud?

0
User Pic

Manual.ly

7 months ago

The device operates similarly to professional medical equipment, which may be noticeable but is not considered overly loud by most users. However, the standard package does not include a specialized baby mask for children under three years old. If you need one for a younger child, you will likely need to purchase a compatible mask separately.

M: qwen/qwen3.5-flash-20260224
M: qwen/qwen3.5-flash-20260224

Frequently Asked Questions

A

The expected average lifespan is four years with regular daily use. If used longer, contact the manufacturer for testing.

Is this answer helpful?

A

No. Never immerse the compressor. Wipe housing with a dry or slightly damp cloth only. Water causes shock risk.

Is this answer helpful?

A

Replace every 200 operating hours or at least once a year. Also change if it looks dirty or damp.

Is this answer helpful?

A

Children must be supervised by an adult. Keep small parts like filters out of reach to prevent choking.

Is this answer helpful?

A

Yes, it is designed for 230V 50Hz. Using different voltage can damage the unit permanently.

Is this answer helpful?

A

No. Using non-recommended parts may damage the device or affect therapy effectiveness.

Is this answer helpful?

A

The warranty covers 24 months from purchase date provided usage is correct and damage is not due to accidents.

Is this answer helpful?

M: qwen/qwen3.5-flash-20260224

Advantages and Disadvantages

Advantages

  • Built-in temperature monitor for safety
  • Quiet operation at 59 dBA
  • Four-year expected lifespan
  • Easy filter replacement system
  • Compact dimensions for home use
VS

Disadvantages

  • No protection against splashing water
  • Compressor can become hot
  • Requires indoor use only
  • Specific brand filter required
  • No outdoor usage capability
M: qwen/qwen3.5-flash-20260224

Product Specification

Type

Compressor (15.95 PSI)

Operation Mode

Mains Powered

Features

Suitable for children, Medication container, Accessory compartment

Noise Level

59 dB(A)

Package Contents

Mouthpiece, Adult mask, Child mask, Connecting hose, Filter

M: qwen/qwen3.5-flash-20260224

Product Description

Breathing Easier at Home with INQUA

Welcome to a new standard in respiratory care designed for every modern household. The Inqua BR021000 Manual describes a reliable companion for your daily treatment needs. This device is engineered specifically for home therapy, ensuring that patients can manage their conditions comfortably and safely within their living space. The system comprises a robust compressor paired with a specialized nebuliser set. It is suitable for both oral and nasal inhalation of liquid medications approved for aerosol therapy. With compact dimensions of 28.5 cm by 22.5 cm, it fits easily on any stable surface or bedside table. The kit includes an adult mask, child mask, mouthpiece, and connection tubing.

Safety First in Everyday Use

Safety is paramount when dealing with devices. The unit features a temperature monitor to prevent overheating of the motor components effectively. A built-in fuse adds an extra layer of protection. Users should always inspect the power cord and plug before each session. The device operates quietly at 59 dBA, making it suitable for family environments. However, users must ensure the surrounding area is not dusty. Covering the device during operation is prohibited.

Technical Precision

The jet flow efficiency is high at 4 l/min. It generates a visible aerosol mist immediately upon activation using ambient air. The operating pressure remains steady at 1.1 bar to ensure deep lung penetration. The expected average lifespan reaches up to four years with regular daily use. The air filter is a critical component that must be replaced every 200 hours or at least annually. Do not use parts from other manufacturers.

Maintenance and Care Instructions

Regular cleaning keeps the unit running smoothly. Wipe the housing with a dry or slightly damp cloth never soaking it. Never immerse the compressor in water or disinfectant solutions due to shock risk. The nebuliser and mask require hygienic re-use preparation according to their specific instructions. Always unplug the device completely before cleaning. Liquid ingress into the compressor housing is a serious risk that requires immediate attention.

Environmental Considerations

The device operates well between 10 and 30 degrees Celsius. Relative humidity should stay between 30 and 75 percent. It is not suitable for outdoor use. The product meets European medical device directives for safety. Proper disposal must follow electronic waste regulations. It contains no user serviceable parts except the filter and requires regular checks. Ensure children cannot access small parts or cords as choking hazards exist.

Conclusion and Support

Whether you need temporary inhalation or long-term therapy, this equipment supports your health journey effectively. Always follow the guidelines for maximum benefit and safety. The Inqua BR021000 Manual provides essential steps for setup and operation. Enjoy efficient therapy with confidence and safety for all family members involved daily. Contact the manufacturer for any warranty claims or spare parts needs.

M: qwen/qwen3.5-flash-20260224