Manual.ly Logo

Hitachi H60MR Manual

0.0 · 0 Ratings

PDF manual · 108 Pages

English

M: OA-GPT-5-NAN
page

/ 108

Loading...
237eabef2e9361cf74e447f3ca21037c86d7 page 2
2
English
Carrying power tools with your fi nger on the switch
or energising power tools that have the switch on
invites accidents.
d) Remove any adjusting key or wrench before
turning the power tool on.
A wrench or a key left attached to a rotating part of
the power tool may result in personal injury.
e) Do not overreach. Keep proper footing and
balance at all times.
This enables better control of the power tool in
unexpected situations.
f) Dress properly. Do not wear loose clothing or
jewellery. Keep your hair, clothing and gloves
away from moving parts.
Loose clothes, jewellery or long hair can be caught in
moving parts.
g) If devices are provided for the connection of
dust extraction and collection facilities, ensure
these are connected and properly used.
Use of dust collection can reduce dust-related
hazards.
4) Power tool use and care
a) Do not force the power tool. Use the correct
power tool for your application.
The correct power tool will do the job better and safer
at the rate for which it was designed.
b) Do not use the power tool if the switch does not
turn it on and off .
Any power tool that cannot be controlled with the
switch is dangerous and must be repaired.
c) Disconnect the plug from the power source and/
or the battery pack from the power tool before
making any adjustments, changing accessories,
or storing power tools.
Such preventive safety measures reduce the risk of
starting the power tool accidentally.
d) Store idle power tools out of the reach of
children and do not allow persons unfamiliar
with the power tool or these instructions to
operate the power tool.
Power tools are dangerous in the hands of untrained
users.
e) Maintain power tools. Check for misalignment
or binding of moving parts, breakage of parts
and any other condition that may aff ect the
power toolʼs operation.
If damaged, have the power tool repaired before
use.
Many accidents are caused by poorly maintained
power tools.
f) Keep cutting tools sharp and clean.
Properly maintained cutting tools with sharp cutting
edges are less likely to bind and are easier to control.
g) Use the power tool, accessories and tool bits
etc. in accordance with these instructions,
taking into account the working conditions and
the work to be performed.
Use of the power tool for operations diff erent from
those intended could result in a hazardous situation.
5) Service
a) Have your power tool serviced by a qualifi ed
repair person using only identical replacement
parts.
This will ensure that the safety of the power tool is
maintained.
PRECAUTION
Keep children and infi rm persons away.
When not in use, tools should be stored out of reach of
children and infi rm persons.
GENERAL POWER TOOL SAFETY
WARNINGS
WARNING
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in
electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
The term “power tool” in the warnings refers to your mains-
operated (corded) power tool or battery-operated (cordless)
power tool.
1) Work area safety
a) Keep work area clean and well lit.
Cluttered or dark areas invite accidents.
b) Do not operate power tools in explosive
atmospheres, such as in the presence of
fl ammable liquids, gases or dust.
Power tools create sparks which may ignite the dust
or fumes.
c) Keep children and bystanders away while
operating a power tool.
Distractions can cause you to lose control.
2) Electrical safety
a) Power tool plugs must match the outlet.
Never modify the plug in any way.
Do not use any adapter plugs with earthed
(grounded) power tools.
Unmodifi ed plugs and matching outlets will reduce
risk of electric shock.
b) Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and
refrigerators.
There is an increased risk of electric shock if your
body is earthed or grounded.
c) Do not expose power tools to rain or wet
conditions.
Water entering a power tool will increase the risk of
electric shock.
d) Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges or
moving parts.
Damaged or entangled cords increase the risk of
electric shock.
e) When operating a power tool outdoors, use an
extension cord suitable for outdoor use.
Use of a cord suitable for outdoor use reduces the
risk of electric shock.
f) If operating a power tool in a damp location
is unavoidable, use a residual current device
(RCD) protected supply.
Use of an RCD reduces the risk of electric shock.
3) Personal safety
a) Stay alert, watch what you are doing and use
common sense when operating a power tool.
Do not use a power tool while you are tired or under
the infl uence of drugs, alcohol or medication.
A moment of inattention while operating power tools
may result in serious personal injury.
b) Use personal protective equipment. Always
wear eye protection.
Protective equipment such as dust mask, non-skid
safety shoes, hard hat, or hearing protection used for
appropriate conditions will reduce personal injuries.
c) Prevent unintentional starting. Ensure the
switch is in the off position before connecting to
power source and/or battery pack, picking up or
carrying the tool.
(Original instructions)
000BookH60MR.indb2000BookH60MR.indb2 2014/11/0715:00:252014/11/0715:00:25

Chat with your Hitachi H60MR manual using AI

Get instant AI answers from your Hitachi H60MR manual

Ask anything about the Hitachi H60MR. Answers come from this manual, with the pages they are based on.

H60MR Maintenance Schedule

Every Carbon Brush Change
Replace grease

Inspect grease level when changing carbon brushes. Replace with 80g of Hitachi Electric Hammer Grease A if needed.

When Worn
Sharpen or replace accessories

Sharpen or replace dull accessories like bull points immediately upon noticing abrasion to maintain efficiency.

Regularly
Inspect mounting screws

Check all mounting screws regularly and retighten any that are loose to prevent hazards.

Regularly
Maintain motor winding

Ensure the motor winding is not damaged or wet with oil or water as it is the heart of the tool.

When Worn
Inspect and replace carbon brushes

Check brushes for wear against the limit mark. Replace both brushes with new ones having the same number if worn.

M: QW-35-FL

Ask a Question

0/1000

Do you recommend H60MR?

Yes No

Frequently Asked Questions

A

The H60MRV adds an electronic, stepless strike-rate dial allowing adjustment from about 930 to 1650 strikes per minute. The base H60MR offers fixed performance characteristics. Both share motor power, accessories and construction.

Is this answer helpful?

A

Standard accessories typically include a protective case, one SDS-max bull point and a side handle. Accessories may vary by market, so always check the package contents and local documentation.

Is this answer helpful?

A

Regular maintenance includes inspecting and tightening mounting screws, keeping cutting accessories sharp, replacing worn carbon brushes, and replacing grease as specified (Hitachi Electric Hammer Grease A). Have service performed by an authorized Hitachi service center when possible.

Is this answer helpful?

A

Wear hearing protection, eye protection, dust mask and safety shoes; use the side handle and two-handed grip to control recoil; confirm the power switch is OFF before connecting power; check for hidden electrical cables or conduits before breaking into walls; use an RCD in damp conditions.

Is this answer helpful?

A

The tool’s input power is 1350 W and full-load impact rate is up to 1650 min-1. Declared vibration for chiselling is ah, Cheq = 16.9 m/s² with uncertainty K = 2.9 m/s². Actual vibration depends on usage; plan exposure controls accordingly.

Is this answer helpful?

A

Consumable parts like carbon brushes can be replaced, but service should ideally be done by qualified personnel. The guarantee covers manufacturing defects per local regulations but not misuse, normal wear or unauthorized repairs; contact an authorized Hitachi service center for warranty claims.

Is this answer helpful?

A

Use Hitachi Electric Hammer Grease A when replacing lubricant. The standard refill volume indicated for the crankcase is approximately 80 g to cover the connecting rod area; follow service instructions and avoid damaging oil seals.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High power: 1350 W motor and up to 1650 impacts/min for heavy demolition tasks.
  • Variable strike rate (H60MRV): stepless electronic dial for 930–1650 strikes/min.
  • Durable construction: airtight crankcase reduces dust ingress and lubricant leakage.
  • Complete kit: includes SDS-max bull point, side handle and protective carrying case.
  • Serviceable design: replaceable carbon brushes and authorized-service support for longevity.
VS

Disadvantages

  • Weight: 10.5 kg (without cord/side handle) may be tiring for prolonged overhead work.
  • High vibration and noise: requires hearing protection and careful exposure management.
  • Maintenance needs: grease replacement and brush checks required to maintain life.
  • Electrical requirements: verify regional voltage and use proper extension cord or RCD.
  • Not ideal for fine work: optimized for demolition rather than precision chiselling.
M: OA-GPT-5-NAN

Product Specification

Power

1350W

No-load impact rate

1600-2160/min

Impact energy

26J

Chisel positions

12

Tool holder

SDS-max quick-release chuck

Special features

Auxiliary handle, Soft grip, Impact rate regulation

Weight

23.15lb

Scope of delivery

Case, Point chisel

M: OA-GPT-54-NAN

Product Description

Hitachi H60MR Electric Breaker/Demolition Hammer incl. Case Manual

The Hitachi H60MR Electric Breaker is a heavy-duty demolition hammer designed for professional concrete breaking, chiselling, grooving and rebar cutting. Supplied with a sturdy carrying case, side handle and SDS-max bull point, the H60MR balances raw impact power with features that improve control, durability and serviceability. With a 1350 W motor and a full-load impact rate rated up to 1650 min-1, this tool is built to tackle demanding construction, plumbing, electrical and civil engineering tasks where reliable, repeatable demolition performance is required.

Key product features

The H60MR delivers high impact energy at a relatively compact weight of 10.5 kg (without cord or side handle). Models include the H60MR and H60MRV (variable-strike model), the latter offering stepless electronic control of strike rate across a dial (approx. 930–1650 strikes/min). Standard accessories include a protective case, an SDS-max bull point and a side handle for improved handling and safety.

Practical use and operation

Designed for rough work, the H60MR is suitable for installing piping and wiring, removing concrete for sanitary and mechanical installations, and many interior and civil engineering jobs. Operators should position the side handle for optimal leverage, use both hands to control recoil, and avoid forcing the tool—using the machine’s weight and correct strike rate yields better efficiency. The variable model’s strike dial allows selection of the ideal impact frequency for chiselling versus heavy demolition.

Maintenance and longevity

Hitachi built the H60MR for longevity: an airtight crankcase prevents dust ingress and lubricant leakage. Periodic grease replacement (Hitachi Electric Hammer Grease A) and routine inspection of carbon brushes, mounting screws and accessories are recommended. Carbon brushes are consumable and must be replaced when worn to the limit; use identical replacement parts and have service performed by authorized centers to maintain safety and guarantee coverage.

Safety and handling highlights

This breaker emits significant vibration and noise—wear hearing protection and appropriate PPE (eye protection, dust mask, safety shoes, helmet). Confirm power supply voltage matches the nameplate, ensure the switch is OFF before connecting power, and always verify no hidden wiring or conduits are present before chiselling into walls or floors. Use an RCD in damp conditions and a suitable outdoor extension cord when required.

Notes

  • Check the unit nameplate for regional voltage variations (110 V, 230 V, 240 V).
  • Vibration emission (chiselling): ah, Cheq = 16.9 m/s2 (uncertainty K = 2.9 m/s2); actual vibration varies with usage.
  • Due to ongoing product development, specifications may change without notice.

Pros and cons are summarized below and an FAQ follows to help buyers and users make informed decisions.

M: OA-GPT-5-NAN

© Copyright 2026 Manual.ly