DS-2TD2636B-15/P Maintenance Schedule

Remind me when maintenance is due
Every 6 Months
Charge built-in battery

For long-term storage, ensure the battery is fully charged every half year to prevent damage.

Periodic
Check electrolytic capacitor

Regular replacement and periodic checking are recommended due to varying average lifespan.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend DS-2TD2636B-15/P?

Yes No

Frequently Asked Questions

A

It is a thermal & optical bi-spectrum network camera designed for temperature measurement, body/face thermography, perimeter defense and intelligent VCA detection in critical infrastructure and public spaces.

Is this answer helpful?

A

Body thermography uses a black-body reference area (if available) where you set emissivity, distance and known temperature. The camera supports auto or manual environmental temperature modes and body temperature compensation to derive accurate human temperature readings.

Is this answer helpful?

A

The camera supports automatic whole-scene thermography and expert mode with point, line and area rules. You can configure pre-alarm/alarm thresholds, filtering time, tolerance, emissivity, reflective temperature, and shielded regions.

Is this answer helpful?

A

Supported options include local memory card (format/quotas), NAS (Net HDD), FTP, and cloud storage. Alarm-triggered images and video clips can be uploaded to configured destinations or emailed to recipients.

Is this answer helpful?

A

Activate via SADP or browser, set a strong password (min. 8 chars, mix of cases, numbers, symbols), enable illegal login lock, configure network settings (IPv4/IPv6, DNS), and consider HTTPS/SSH and IP filters for enhanced security.

Is this answer helpful?

A

Yes. In the optical channel enable Face Detection and Face Capture, adjust pupil distance, sensitivity and quick-shot settings. The system can upload captured faces, overlay temperature and trigger audible warnings for no-mask linkage where supported.

Is this answer helpful?

A

Accuracy depends on mounting angle (<45° recommended), target pixel size (≥5×5), correct emissivity, distance, reflective objects, and stable environment. Use a black-body calibration, set filtering and tolerance, and allow sufficient patrol intervals for moving presets.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Dual thermal and optical channels enable temperature measurement plus high-detail face capture and verification.
  • Advanced thermography modes (point, line, area) with black-body calibration for improved temperature accuracy.
  • Comprehensive alarm linkage: FTP/NAS/cloud uploads, email, audible warnings, flashing lights, recording triggers.
  • Rich image controls (WDR, DNR, palettes, ROI, DDE) and privacy/overlay options for tailored monitoring.
  • Flexible network and storage support: IPv4/IPv6, RTSP/HTTP/HTTPS, UPnP/NAT, memory card, NAS, FTP, cloud.
VS

Disadvantages

  • Accurate body temperature screening requires careful calibration (black body) and correct environmental setup.
  • Thermography accuracy can be affected by mounting angle, distance, emissivity and scene reflections.
  • Many advanced features and security settings require trained installers and regular maintenance.
  • High-resolution streams and advanced encoding increase bandwidth and storage demands.
  • Some linkage or audio/lighting features are model-dependent and may not be available on every unit.
M: OA-GPT-5-NAN

Product Specification

Type

Bullet

Image Sensor

1/2.7" CMOS

Resolution

2688x1520 Pixels (25fps)

Lens

0.24 in (F1.5)

Light Sensitivity

0.0089 Lux (Color), 0.0018 Lux (B/W)

Viewing Angle

51.7° (horizontal), 28° (vertical)

Compression/Codecs

MJPEG, H.264, H.264+, H.265, H.265+, G.711, G.722, G.726, MP2L2, PCM

Multistreaming

supported

Alarm

2x Alarm Input/Alarm Output

Connections

1x Audio Input/Audio Output, 1x BNC, 1x RJ-45 100Mb LAN, 1x serial (RS-485)

Data Storage

1x microSD-Slot (max. 128GB)

Illumination

IR Illumination (164.04 ft)

Power Supply

PoE (Type 1)

Protection Class

IP66

Housing

suitable for outdoor use

System Compatibility

ONVIF (Profile G, S, T), IPv6

Zone & Analysis Functions

Motion Detection, IR Filter

Special Features

Temperature Sensor (0.59 in, F1.0)

Manufacturer Warranty

3 Years

M: OA-GPT-54-NAN

Product Description

Hikvision DS-2TD2636B-15/P 6mm Manual Overview

The Hikvision DS-2TD2636B-15/P 6mm is a thermal & optical bi-spectrum network camera combining thermal imaging and visible-light channels with a 6mm lens. Built with an onboard GPU and advanced algorithms, it supports temperature measurement, body and face thermography, VCA (video content analysis) detection, and multiple alarm/linkage options. Designed for perimeter defense, fire-prevention, and human temperature screening, it suits communities, industrial sites, retail environments, and other critical infrastructure.

Key features and capabilities

The camera supports automatic and expert thermography modes—point, line, and area measurement—displaying max/min/average temperatures and configurable color palettes. Body thermography detects face or body temperatures in both thermal and optical channels, with black-body calibration, emissivity and distance settings, environmental temperature control, and compensation options to improve accuracy for human temperature screening.

On the visible channel the unit provides face detection and capture with configurable pupil distance, sensitivity, quick-shot options and mask detection linkage. Captured faces and metadata (temperature, time, overlays) can be uploaded and stored through FTP, NAS, cloud, or local memory card. Privacy masks, picture-in-picture, OSD overlays, and image-enhancement tools (DNR, WDR, AGC, DDE, palette settings) help tailor image presentation.

Installation, activation and security

Activation is supported via SADP or browser-based setup; strong password policies and illegal login lock are recommended. Network settings include IPv4/IPv6 support, DHCP/manual addressing, multicast discovery, UPnP/NAT port mapping, RTSP/HTTP/HTTPS ports, and Hik-Connect integration. System management covers firmware upgrade, configuration import/export, logs, diagnostics, and role-based user permissions.

Event, alarm and linkage

The camera supports motion detection (normal/expert modes), video tampering, audio exception detection, external alarm input/output, and exception alarms (HDD/network/illegal login). Alarm linkage options include recording triggers, FTP/NAS/cloud uploads, email notifications, audible warnings, flashing lights, and notifying surveillance centers. Arming schedules and advanced filtering/tolerance settings reduce false positives.

Storage, recording and playback

Storage options include local memory card (format/quotas), NAS, FTP, and cloud. Recording modes include continuous, motion, alarm, and event-triggered recording with pre/post-record buffers, overwrite settings, multi-stream selection and clip/download via web playback. Snapshot capture supports timing or event triggers, customizable formats and overlay settings.

Practical use and maintenance

Operational guidelines emphasize correct mounting angle (<45° oblique recommended), ensuring sufficient pixel size for targets (≥5×5), regular battery and component checks, and safe transport/installation. Calibration with a black body is advised for accurate body thermography. Regular firmware updates and secure configuration are recommended to maintain accuracy and security.

Notes

  • For accurate temperature measurement, follow emissivity, distance, and black-body calibration procedures.
  • Use expert mode for precise thermography rules (point/line/area) and set filtering/tolerance to avoid false alarms.
  • Ensure network and email settings (DNS, SMTP) are correctly configured before enabling notifications.
  • Face capture and mask detection require proper face detection parameter tuning (pupil distance, sensitivity).
M: OA-GPT-5-NAN

© Copyright 2026 Manual.ly