M80 MTL 670 Maintenance Schedule
Clean the ladder, especially all moving parts, immediately after use if visible soiling is present. Use only standard water-soluble cleaning agents.
Check for damage and ensure safe use before each operation. Do not use a damaged ladder.
The ladder must be checked regularly for damages. Repairs and maintenance must be carried out by a competent person according to manufacturer instructions.
Ask a Question
Do you recommend M80 MTL 670?
Yes NoDo you recommend M80 MTL 670?
Yes NoFrequently Asked Questions
The ladder is specified for a maximum total load of 150 kg. Always follow the instructions for the exact product variant and use the ladder only as intended.
Is this answer helpful?
It uses the hinge joint to convert between stepladder and leaning ladder configurations. The foldable ladder part is unlocked, positioned, then locked again. For setting one part, both safety joints on opposite sides must be activated.
Is this answer helpful?
Use the extendable ladder legs. Unlock via the side locking clamps, move each leg to the desired position, then re-lock by inserting the clamps into the locking opening. Both clamps must be engaged.
Is this answer helpful?
Inspect for completeness and transport damage, then do a visual check before each use. Confirm that the hinge joint and locking clamps are locked, rungs are not damaged, ladder feet are secure, and labels are present and legible.
Is this answer helpful?
No. The instructions specify that the top rungs/steps must not be used as standing surfaces (including limits for leaning and standing configurations). Follow the safe rung guidance in the instructions.
Is this answer helpful?
Outdoors, consider wind and secure positioning. For electrical hazards, identify risks in the work area and do not use the ladder where electrical danger exists. Do not use the ladder as a bridge or modify its design.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Multiple configurations: stepladder, leaning single ladder, and stairway-compatible setup using the hinge mechanism
- Snap-in hinge joint with preset locking positions helps place the ladder securely
- Adjustable height with extendable ladder legs and side locking clamps for fine positioning
- EN 131-4 compliant and classified for both non-professional and professional use
- Max total load 150 kg (variant dependent) with a clear safety approach and inspection plan
Disadvantages
- Must be fully locked before use; hinge joints and locking clamps need verification every time
- Strict limitations on safe use: avoid contaminated/uneven ground, do not overreach, do not use top rungs as stand surfaces
- Electrical hazard rules apply: do not use near exposed electrical equipment, and do not modify the ladder
- Outdoor use requires extra caution for wind and requires secure positioning to prevent collision and tipping risks
Product Specification
Type
Telescopic multi-purpose ladder
Material
Aluminum
Steps
4x 6
Working height
max. 265.75 in
Platform height
none
Load capacity
max. 330.69 lb
Special features
Anti-slip feet, foldable
Weight
39.90 lb
Product Description
Hailo M80 MTL 670 Alu 4-part Telescope Multi-Purpose Ladder - 4 x 6 Rungs (Manual)
If you need controlled access for small jobs at height, the Hailo M80 MTL 670 Alu 4-part Telescope multi-purpose ladder 4 x 6 rungs Manual-style design focuses on fast setup and dependable locking. This single-hinge joint ladder uses an extendable side leg system and a hinge mechanism with preset snap-in positions, helping you switch between practical working configurations without guesswork.
Versatile setup for real work
The ladder can be arranged in multiple ways: as a stepladder, as a leaning single ladder, and also as a stairway-compatible ladder configuration. Two extendable ladder legs adjust working height, while the hinge joint conversion uses the foldable ladder part and safety joints to lock into the desired position.
Specs you can plan around
For the 4 x 6 rungs variant, the ladder is designed for a maximum total load of 150 kg. Typical weight is about 18.1 kg (dimensions and weights are approximate). The ladder is made of high-quality aluminum and meets the requirements of EN 131-4, and it is classified for both non-professional and professional use.
Safety comes first
The instructions emphasize that safe use depends on correct locking and surface conditions. Before every use, check the ladder for damage and ensure the hinge joint and locking clamps are fully engaged. Keep a secure handhold when climbing, avoid sideways loads (for example, side-on drilling), do not overreach, and never use contaminated ground. For electrical risks, do not use the ladder near exposed electrical equipment, and do not use it as a bridge.
Key results
- Quick conversion between stepladder and leaning ladder positions using hinge joint locking and preset snap-in stages
- Height adjustment via extendable ladder legs with side locking clamps for controlled positioning
- EN 131-4 compliant design for both non-professional and professional applications
- Clear inspection and limits: max load 150 kg, and restrictions on using top rungs as standing surfaces
Pros
- Multiple working configurations (stepladder, leaning ladder, stair-compatible use)
- Locking system with snap-in hinge positions and locking clamps
- Adjustable height with extendable ladder legs
- Intended for both non-professional and professional use, meeting EN 131-4
Cons
- Requires careful pre-use checks and fully engaged locks every time
- Not suitable on contaminated or uneven, unstable surfaces
- Limited by safety rules such as no bridge use, avoid sideways loading, and rung-use restrictions
- Electrical and wind conditions demand extra caution
Notes
- After delivery and before each use, inspect hinge joints, locking clamps, ladder feet, rungs, fastenings, and labels.
- For access to a higher level, extend the ladder at least 1 m beyond the landing point and secure if needed.
- For ongoing professional use, plan regular inspections and remove defective ladders from service.