EN
SAFETY INSTRUCTIONS
This manual contains safety and operating instructions.
Read it carefully before using the device for the first time and keep
it in a safe place for future reference.
This machine should only be used for charging operations comprised
within the limits indicated on the machine and in the instruction
manual. The operator must respect the safety precautions. In case of
inadaquate or unsafe use, the manufacturer cannot be held liable.
The machine is designed to be used indoors. Must not be exposed
to the rain.
This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved. Children shall not
play with the appliance. Cleaning and user maintenance shall not
be made by children without supervision.
Do not use to charge small batteries or non rechargeable batteries.
Do not use the charger if the mains cable or the plug is damaged.
Never use on a frozen or damaged battery.
Do not cover the device.
Do not place the unit near a heat source and long lasting high
temperatures (above 50 ° C).
The automatic mode and the restrictions applicable to its use are
detailed in the following instruction manual.
Fire and explosion risks!
• A charging battery can emit explosive gases.
• During the charge, the battery must be placed in a well ventilated
area.
• Avoid flames and sparks.
• Protect the batterie’s electrical contact surfaces against short-
circuits.
Risk of acid projections !
• Wear protective goggles and gloves.
• In case of contact with the eyes or skin, rinse well with water and
see a doctor as soon as possible.

Chat with your GYS GYSFLASH 50.24 HF manual using AI

Get instant AI answers from your GYS GYSFLASH 50.24 HF manual

Ask anything about the GYS GYSFLASH 50.24 HF. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend GYSFLASH 50.24 HF?

Yes No

Frequently Asked Questions

A

It supports lead-acid (liquid, sealed, AGM), gel, and lithium LiFePO4 batteries at 6V, 12V, and 24V voltages.

Is this answer helpful?

A

No, this device is designed for stationary vehicles only. It is intended for indoor use and must not be exposed to rain.

Is this answer helpful?

A

Access the Advanced Menu using code 1964 and set Power Supply to ON. This mode is hidden by default.

Is this answer helpful?

A

The device has an automatic restart feature that resumes charging automatically once power is restored in Charge, Showroom, or Power Supply modes.

Is this answer helpful?

A

Yes, changing cables requires recalibration via the Cables Check menu to ensure accurate performance.

Is this answer helpful?

A

Yes, the charger can operate standalone or connected to the vehicle, provided the correct safety procedures are followed.

Is this answer helpful?

A

Disconnect power immediately, swap the red clamp to positive and black to negative, then reconnect carefully.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Supports multiple battery types including Lithium LiFePO4
  • High power output up to 50A for diagnostic needs
  • Automatic restart feature after power cuts
  • Protects vehicle memory during battery changes
  • Customizable Expert charging curves for advanced users
VS

Disadvantages

  • Hidden modes require code entry to activate
  • Requires recalibration when changing cables
  • Fixed unit design limits portability
  • Expert mode may damage electronics if misconfigured
  • No battery detection required for some advanced functions
M: QW-35-FL

Product Specification

Battery Voltage

6V, 12V, 24V

Max. Charging Current

50A

Battery Capacity

10-600Ah

Display

LCD

Color

white, gray

Dimensions

11.81x4.13x11.50in (WxDxH)

Weight

13.23lb

M: QW-35-FL

Product Description

GYS Flash 50.24 HF: The Ultimate Battery Charging Solution

The GYS Flash 50.24 HF represents a pinnacle in automotive battery maintenance technology. This high-power stabilized power supply utilizes advanced SMPS (Switch Mode Power Supply) technology to support and charge batteries ranging from 6V to 24V. Whether you are dealing with liquid, AGM, or gel batteries, this device ensures an ideal charging cycle for modern vehicles during diagnostic phases or routine maintenance.

Designed as a fixed unit rather than a mobile tool, the GYS Flash 50.24 HF offers versatility through five distinct operating modes. The default Automotive mode handles starter batteries from 10Ah to 600Ah, while the Traction mode is optimized for larger batteries up to 450Ah. For professionals conducting diagnostics, the Diag+ mode supplies up to 50A to compensate for high-energy consumers like engine fans or window regulators without draining the vehicle's battery. The Showroom mode allows demonstration vehicles to run accessories continuously while maintaining battery health.

Advanced users will appreciate the hidden Power Supply mode, which transforms the charger into a powerful regulated power source with adjustable voltage and current limits. Additionally, the optional Change Battery mode prevents data loss in vehicle electronics during battery replacement by providing stable power. Safety is paramount, with built-in protections against short circuits, polarity inversion, and sparks. The device features an automatic restart function to resume charging after power outages, ensuring your work is never interrupted.

Key Features and Benefits

The GYS Flash 50.24 HF supports cables up to 2x8 meters in 16mm², making it suitable for various workshop setups. Its intuitive interface guides users through Easy, Liquid, Gel/AGM, LFP/LiFePO4, and customizable Expert charging curves. The Expert curve allows precise configuration of charging parameters for complex battery recovery scenarios. With multi-language support and compliance with European directives, this charger is a reliable partner for any serious technician.

Important Notes

  • Always disconnect power before connecting or disconnecting clamps.
  • Ensure proper ventilation when charging to avoid explosive gas accumulation.
  • Use protective gear such as goggles and gloves when handling batteries.
  • Do not charge non-rechargeable or frozen batteries.
  • Calibrate the device whenever cable lengths are changed.