Yes, the device supports Lithium Iron Phosphate (LiFePO4) batteries in the Automotive mode. You must select the correct LFP curve and input the battery capacity for optimal charging results.
Is this answer helpful?
Navigate to the Advanced Menu by entering the code 1-9-6-4. Select the Power Supply option and switch it to ON. This will make the mode visible in the main menu list for future use.
Is this answer helpful?
Immediately stop the process. Disconnect the charger from the mains. Check your clamps and ensure the red clamp is connected to the positive terminal and the black clamp to the negative terminal before restarting.
Is this answer helpful?
Yes, but only in Charge, Showroom, and Power Supply modes. You must enable the Automatic Restart function in the configuration menu for this feature to work effectively.
Is this answer helpful?
If the current is above 10A, it usually indicates the battery is deeply discharged or there are active consumers on the vehicle. Turn off all electrical accessories and wait for the current to drop below 10A before proceeding.
Is this answer helpful?
Yes, by activating the Battery Change mode in the Advanced Menu. Connect the clamps correctly before removing the old battery to maintain stable power and preserve the vehicle's electronic memory.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Supports multiple battery types including LiFePO4, AGM, and Gel
- High current output up to 30A for diagnostic testing
- Automatic restart feature resumes charging after power cuts
- Expert mode allows full customization of charging curves
- Anti-spark technology prevents dangerous arcing during connection
Disadvantages
- Hidden modes require code entry to activate which may confuse new users
- Power Supply mode does not compensate for voltage drop in long cables
- Cables must be recalibrated whenever they are replaced
- Internal fuse replacement requires qualified personnel only
- Device is considered fixed equipment and not portable
Product Specification
Battery Voltage
6V, 12V, 24V
Max. Charging Current
30A
Battery Capacity
10-400Ah
Display
LCD
Color
white, gray
Dimensions
10.04x4.13x9.06in (WxDxH)
Weight
8.38lbs
Product Description
Discover the Power of GYS Flash 30.24 HF
The GYS Flash 30.24 HF is a high-performance stabilized power supply designed for professional automotive diagnostics and battery maintenance. Utilizing advanced Switch Mode Power Supply (SMPS) technology, this device supports 6V, 12V, and 24V batteries, making it versatile for a wide range of vehicles from compact cars to heavy machinery. Whether you are working with liquid, AGM, or gel batteries, this charger ensures an ideal charging cycle while providing stable power during complex diagnostic procedures.
Versatile Charging Modes
This unit features five distinct operating modes to meet various needs. The default Automotive mode handles starter batteries ranging from 10 Ah to 400 Ah across different voltages. For heavy-duty applications, the Traction mode charges large electrolyte batteries efficiently. During vehicle diagnostics, the Diag+ mode supplies up to 30A to keep systems running while testing high-consumption components like window regulators or electronic suspensions. The Showroom mode is perfect for demonstration vehicles, maintaining electrical functions without draining the battery. Additionally, two hidden modes offer specialized capabilities: Battery Change mode preserves vehicle memory during replacements, and Power Supply mode acts as a robust bench power source for experts.
Advanced Configuration and Safety
The GYS Flash 30.24 HF includes sophisticated safety features such as anti-spark protection, short-circuit prevention, and polarity inversion safeguards. Users can customize charging curves using the Expert menu, allowing for precise control over voltage and current parameters for lithium or deeply discharged batteries. The device also features automatic restart functionality, ensuring that charging cycles resume immediately after a power interruption. With support for cables up to 8 meters long and easy recalibration options, this tool is built for reliability in demanding workshop environments.
Important Notes
- Always disconnect power before connecting clamps to prevent sparks.
- Ensure the battery is in a well-ventilated area to avoid gas accumulation.
- Use protective gear when handling lead-acid batteries.
- Do not charge non-rechargeable or frozen batteries.
- Regularly check cable connections for wear and tear.