GLACIER
CAMP STOVE
A
C
B
D
E
Read and understand this entire instruction manual before using this stove. Keep this
instruction manual for future reference. Practice using this stove before heading out
on your trip to familiarize yourself with its function and dangers. If you do not
understand this manual or have any questions, please call GSI Outdoors, Inc. at
1-800-704-4474, +1- 509-928-9611, email us at info@gsioutdoors.com or visit
our website at www.gsioutdoors.com.
Do not attempt to use this stove: (1) before reading and fully understanding this
instruction manual; (2) if you are not prepared or comfortable attending to a burning
and/or hot stove at all times; (3) if you observe, smell or hear leaking fuel; or (4) if you
observe any condition with the stove system or in the surrounding environment that
would make operation of an open flamed device dangerous. Failure to follow these
directions can cause an unsafe situation leading to fire or an explosion, resulting in
serious bodily injury or death.
W A R N I N G
Do not use stove if parts are missing or broken, or with replacement parts not specific
to your stove model. Use of stove with missing or broken parts, or with replacement
parts not specific to your stove model, can result in burns, severe injury or death.
Do not attempt to modify or use this stove in any way for any purpose other than
described in this instruction manual
I M P O R T A N T
This stove is designed for OUTDOOR USE ONLY for boiling water and cooking food.
Use of stove within any enclosed space, or for a purpose other than boiling water or
cooking food can cause fire, explosion or poisoning resulting in serious bodily injury
or death. You are responsible for your own safety and the safety of those around you.
This manual is not intended to replace your good judgment. If you have any questions
or concerns contact GSI Outdoors, Inc. at 1-800-704-4474, +1- 509-928-9611, email
us at info@gsioutdoors.com or visit our website at www.gsioutdoors.com.
SAFETY INFORMATION
PARTS:
a: Pot Supports b: Burner Head c: Valve Body d: Flame Adjuster Valve
e: Flame Adjuster
Nominal Heat
Input Rate:
12,970 BTU/h.
3.8 kW
272 g/h.
Injector Size:
0.3 mm
(359/CS/2272)
2009/142/EC
Nominal Heat
Input Rate:
0845-17
Clearance to combustibles: top 4 ft. (1.2 m), sides 4 ft. (1.2 m)
*Nominal Heat Input Rate varies depending on test procedures of the particular standards agency.
11,000 BTU/h.
3.22 kW
IGNITION HAZARD
This stove can easily ignite surrounding materials and flammable liquids or vapors. Keep
stove and cartridge away from other heat sources. NEVER USE WITH WIND SCREEN.
INJURY HAZARD
Never let children use this stove. Supervise children in the cooking area at all times,
keeping them at least 10 feet (3+ meters) away from the stove.
WARNING
Handling this product exposes you to lead, a chemical known to the State of
California to cause cancer, birth defects or other reproductive harm. WASH YOUR
HANDS AFTER HANDLING THIS PRODUCT.
D A N G E R
This stove uses a liquid pressurized gas (LPG) cartridge that is highly flammable and
explosive. Use only GSI Outdoors isoButane Fuel Cartridges of Isobutane and
Propane mix (4 oz./110 g, 8 oz./230 g or 16 oz./450 g). Because GSI Outdoors cannot
assure the quality and safety of other manufacturers’ fuel cartridges, do not attempt
to fit other types or makes of gas cartridges to the Glacier Stove. Follow this safety
information when using GSI cartridges:
!/ Listen and smell for leaking gas. Leaking gas is a serious hazard. Natural LPG is
invisible and odorless; strong odorant additives have been added to the fuel mix
but can fade over time. Leaks are not always detectable by smell. Do not use this
stove if it is leaking, damaged, or does not operate properly.
GENERAL FUEL CARTRIDGE SAFETY
This appliance can produce carbon
monoxide which has no odor.
Using it in an enclosed space can
kill you.
Never use this stove in an enclosed
space such as a camper, tent, car
or home.
DANGER
CARBON MONOXIDE HAZARD
If you smell gas:
1/ Do not attempt to light appliance.
2/ Extinguish any open flame.
3/ Disconnect from fuel supply.
FOR YOUR SAFETY
Do not store or use gasoline or other
liquids with flammable vapors in the
vicinity of this or any other appliance.
FOR YOUR SAFETY
LIMITED WARRANTY/LIMITATIONS OF REMEDIES AND LIABILITY
USA, Canada and other applicable Countries
Limited Warranty :
GSI Outdoors, Inc. USA (GSI Outdoors) to the original owner (“Owner”), under
intended use and maintenance, warrants the enclosed product (“Product”) to be free
from defects in materials and workmanship for the life of the Product. No warranty
against defects in materials and workmanship will apply if Product is (i) altered in any
way, (ii) used for purposes inconsistent with Product’s intended purpose or design, or
(iii) improperly maintained. Warranty will furthermore be voided where Owner/user
(i) failed to follow Product instructions or warnings or (ii) subjected Product to misuse,
abuse, or neglect.
During the warranty period, original product parts determined by GSI Outdoors, Inc.
to be defective in materials or workmanship will be repaired or replaced as Owner’s
sole remedy. GSI Outdoors, Inc. reserves the right to replace any discontinued
product with a new product of comparable value and function. A returned Product
deemed irreparable becomes the property of GSI Outdoors, Inc. and will not be
returned.
EXCLUDING THE LIMITED WARRANTY PROVIDED ABOVE, GSI OUTDOORS, INC., ITS
AFFILIATES AND THEIR SUPPLIERS, TO THE MAXIMUM EXTENT PERMITTED BY
LAW, MAKE NO WARRANTIES, EXPRESSED OR IMPLIED, AND DISCLAIM ALL
WARRANTIES, DUTIES AND CONDITIONS, WHETHER EXPRESSED, IMPLIED OR
STATUTORY, WITH RESPECT TO THE PRODUCT, INCLUDING WITHOUT LIMITATION
W A R R A N T Y
!/ Check that the stove and fuel cartridge connection is secure and tight. If the
connection does not look or feel secure, or if you hear or smell leaking gas, do not
use stove or cartridge. Move stove to a well-ventilated area away from any
ignition source to locate and stop the leak. Only check for leaks outdoors using
soapy water. Bubbles will form if the soapy water is poured over a leak. Do not try
to detect leaks using a flame.
!/ Only change the cartridge outside and at least 25 feet (7.6 meters) from people and
any source of ignition.
!/ Always position stove on a stable, solid level surface before using stove. Check
and if necessary clean the seals for dust, proper seating or any wear before
connecting a new fuel cartridge to the stove. Do not use stove if seals are
damaged or worn.
!/ Keep stove and fuel cartridge at least 25 feet (7.6 meters) away from other heat
sources. If you expose the fuel cartridge to high heat, the cartridge will explode or
leak resulting in serious bodily injury or death. This stove can ignite combustible
materials, flammable liquids and vapors creating a situation where fire, burns,
severe injury or death can result.
!/ Follow all warnings on fuel cartridges regarding use and storage.
GENERAL FUEL CARTRIDGE SAFETY
ANY IMPLIED WARRANTIES OF MERCHANTABILITY, AGAINST LATENT DEFECTS,
FITNESS FOR A PARTICULAR PURPOSE, OR CORRESPONDENCE TO DESCRIPTION.
Warranty Service. To obtain service under this warranty, the warranty-eligible
Product must be presented to GSI Outdoors, Inc. by calling 1-800-704-4474 [M-F,
8:00-4:30, PDT] or emailing info@gsioutdoors.com.
Owner is responsible for all costs associated with returning Product to GSI Outdoors
for service. Where at its sole discretion GSI Outdoors deems Product eligible for
warranty repair or replacement, GSI Outdoors will pay the shipping and handling
associated with returning repaired or replaced Product to Owner. In instances where
GSI Outdoors deems a returned product ineligible for warranty service, GSI Outdoors
will, if possible, repair products for a reasonable charge that includes return shipping
and handling. For warranty return service details, please go to
www.gsioutdoors.com.
Limitation of Remedies. Should a court of competent jurisdiction find the limited
warranty set forth above breached, GSI Outdoors’ only obligation will be to, at its
option, either repair or replace Product. Should the aforementioned remedy fail of its
essential purpose, GSI Outdoors will, in exchange for return of Product, refund to
Owner Product’s original purchase price. THE FOREGOING REMEDY IS THE SOLE
AND EXCLUSIVE REMEDY OF THE PURCHASER AGAINST GSI OUTDOORS, ITS
AFFILIATES AND THEIR SUPPLIERS, REGARDLESS OF LEGAL THEORY.
Limitation of Liability. GSI Outdoors’, its affiliates’ and their suppliers’ maximum
W A R R A N T Y W A R R A N T Y
liability is limited to incidental damages not to exceed the original purchase price of
the Product. GSI OUTDOORS, ITS AFFILIATES AND THEIR SUPPLIERS HEREBY
DISCLAIM AND EXCLUDE ANY REASON WHATSOVER. THIS EXCLUSION AND
LIMITATION APPLIES TO ALL LEGAL THEORIES UNDER WHICH DAMAGES MAY BE
SOUGHT, AND WILL APPLY EVEN IF ANY REMEDY FAILS OF ITS ESSENITAL
PURPOSE.
This limited warranty gives Owner specific legal rights; Owners may have additional
rights, which may vary state to state.
Always completely follow safety, use operation, and maintenance instructions for
this or any other GSI Outdoors product.
European Union customer statutory rights are not affected.
GSI Outdoors, Inc.
For product service and information contact
GSI Outdoors, Inc. USA
1023 S. Pines Road, Spokane WA. 99206 USA
1-800-704-4474 or 509-928-9611
www.gsioutdoors.com
KNOW YOUR STOVE BEFORE YOU GO!
Familiarize yourself with the parts of your GSI Outdoors Glacier Camp Stove and the
instructions for use and storage before connecting the stove to its fuel cartridge.
Never use this stove in any other way than is described in the following instructions.
For more information or videos on how to use the GSI Outdoors Glacier Camp Stove
visit our website at www.gsioutdoors.com
#56004: Glacier
®
Camp Stove
© 2017 GSI Outdoors, Inc.
1023 S Pines Rd Spokane WA 99206 USA
PO Box 132 Wakefield, England WF1 1XJ

Chat with your GSI Glacier Camp manual using AI

Get instant AI answers from your GSI Glacier Camp manual

Ask anything about the GSI Glacier Camp. Answers come from this manual, with the pages they are based on.

Glacier Camp Maintenance Schedule

Before each new fuel cartridge
Inspect and clean the seals

Check seals for dust, proper seating, and wear before connecting a new fuel cartridge. Do not use the stove if seals are damaged or worn.

After each cartridge installation
Check for gas leaks

Check for leaks outdoors using soapy water after installing a fuel cartridge. Bubbles indicate a leak; never test with a flame.

Before and after lighting below freezing
Check for fuel leaks in freezing temperatures

In below-freezing conditions, inspect for leaks before and after lighting because O-rings can harden and leak fuel.

M: gpt-5.6-terra

Ask a Question

0/1000

Do you recommend Glacier Camp?

Yes No

Video Manual

GSI GLACIER CAMP STOVE/REVIEW & DEMO/JUNE 2025

Frequently Asked Questions

A

No. The stove produces carbon monoxide and must be used outdoors only. Using it in enclosed spaces like tents, campers, cars or homes can cause poisoning, fire, explosion and death.

Is this answer helpful?

A

Use only GSI Outdoors isoButane fuel cartridges (isobutane/propane mix) in sizes 4 oz/110 g, 8 oz/230 g or 16 oz/450 g. GSI does not guarantee safety or fit with other manufacturers' cartridges.

Is this answer helpful?

A

Check for leaks outdoors using soapy water applied to connection points; bubbles indicate a leak. Do not use an open flame to test for leaks. If you detect a leak, do not use the cartridge or stove.

Is this answer helpful?

A

Keep combustibles at least 4 ft (1.2 m) from the stove, flammable liquids and vapors at least 25 ft (7.6 m), and children/pets at least 10 ft (3+ m) away. Keep the cartridge and stove away from other heat sources.

Is this answer helpful?

A

Close the flame valve, connect cartridge securely, place a lit match or lighter at the burner edge, then open the flame adjuster about 3/4 turn to ignite. Adjust flame to desired setting (approx. 1/4 turn for optimal efficiency). Never lean over the stove while lighting.

Is this answer helpful?

A

Turn the flame regulator off, allow the stove to cool completely (about 10 minutes), disconnect the cartridge, and store the stove and cartridge in a clean, dry place away from heat and ignition sources.

Is this answer helpful?

A

Yes. GSI offers a limited warranty against defects in materials and workmanship for the product's life when used and maintained as directed. Warranty is void for misuse, modification or improper maintenance; owner pays return shipping for service.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Lightweight, compact design ideal for backpacking and fast boiling.
  • High nominal heat input (~12,970 BTU/h) for efficient cooking and rapid boil times.
  • Simple, reliable mechanical controls: burner head, valve body and flame adjuster.
  • Clear safety and maintenance instructions reduce risk when followed properly.
  • Compatibility with GSI isoButane cartridges ensures predictable fuel performance.
VS

Disadvantages

  • Strict outdoor-only use—produces carbon monoxide; unusable in enclosed spaces.
  • Requires proprietary GSI fuel cartridges; other brands not recommended.
  • Not safe with wind screens, large or non-flat cookware, limiting some setups.
  • Pressurized LPG cartridge risk: leaks, freezing O-rings, and potential explosion.
  • Warranty void if misused, modified, or improperly maintained; owner bears return costs.
M: OA-GPT-5-NAN

Product Specification

Type

Stove

Colors

silver

Boil time for 1l

4 min

Fuel

Gas

Dimensions

5.12x5.12x3.15in

Weight

0.37lb

Package contents

1x Carry bag

M: OA-GPT-54-NAN

Product Description

GSI Glacier Camp Stove Manual — Reliable Lightweight Outdoor Stove

The GSI Glacier Camp Stove is a compact, high-output backpacking stove designed for outdoor cooking and boiling water. Built for campers, backpackers and day-trippers who prioritize weight, reliability and simplicity, the Glacier offers straightforward controls, durable construction and clear safety guidance. It runs on GSI Outdoors isoButane fuel cartridges (isobutane/propane mix) and features a burner head, pot supports, valve body and a flame adjuster for precise heat control.

With a nominal heat input rate of up to ~12,970 BTU/h (3.8 kW) depending on test method, the stove brings water to boil quickly while keeping fuel consumption efficient. The 0.3 mm injector and compact burner design produce a nearly blue, high-efficiency flame. The stove is intended strictly for outdoor use; its instructions emphasize never using it in enclosed spaces due to carbon monoxide risk and explosive hazard from pressurized LPG cartridges.

Key practical guidance includes always using the stove on a stable, level surface clear of combustibles, maintaining recommended clearances (about 4 ft/1.2 m to combustibles and 25 ft/7.6 m to flammable liquids or ignition sources), and keeping children and pets at least 10 ft (3+ m) away. The manual stresses leak checks with soapy water only (never open flame), proper cartridge connection without over-tightening, and replacing worn or damaged seals before use. It warns about cold-weather O-ring stiffness and to check for leaks before and after lighting.

Lighting and operation are simple: secure the cartridge, close the flame valve, light a match or lighter at the burner edge, open the flame adjuster about 3/4 turn to ignite, then adjust to desired heat (about 1/4 turn for optimum efficiency). Never use wind screens, never operate with oversized or non-flat cookware, and never heat empty cookware. After cooking, close the flame regulator, wait for the unit to cool, disconnect the cartridge, and store both in a clean, dry place.

GSI provides contact information and a limited warranty: defects in materials or workmanship may be repaired or replaced under specified conditions, with the owner responsible for return shipping. The warranty is voided by misuse, modification or improper maintenance. Safety, operation and maintenance instructions must be followed to avoid fire, burns, explosion or carbon monoxide poisoning.

Notes:

  • Use only GSI isoButane fuel cartridges sized 4 oz/110 g, 8 oz/230 g or 16 oz/450 g.
  • Always perform leak checks outdoors with soapy water; do not use a flame to detect leaks.
  • Keep stove and cartridge away from heat sources; never use a windscreen.