User Manual V1.5-2023-01-30
Maintenance
2
1
Maintaining Item Maintaining Method Maintaining Period
System Clean
Check the heat sink, air intake, and air
outlet for foreign matter or dust.
Once 6-12 months
Electrical Connection
Check whether the cables are securely
connected. Check whether the cables are
broken, or whether there is any exposed
copper core.
Once 6-12 months
Sealing
Check whether all the terminals and ports
are properly sealed. Reseal the cable hole
if it is not sealed or too big.
Once a year
THDi Test
For Australia requirements, in the THDi
test, there should add Zref between
inverter and mains.
RA=0, 24; XA=j0,15 at 50Hz;
RN=0, 16; XN=j0,10 at 50Hz
As needed
WiFi module: Replace or remove the WiFi module using the WiFi
module remover, which is delivered in the package. Remove the
communication terminal next to the WiFi module rst. Place the
remover horizontally on the WiFi module, then turn the remover to
90° to fasten it and the module together. Press the remover and pull
the module to remove it as the following gure shows.
Notice: If you need to repair or replace parts, contact the after sales
service.

Chat with your Goodwe BH Series manual using AI

Get instant AI answers from your Goodwe BH Series manual

Ask anything about the Goodwe BH Series. Answers come from this manual, with the pages they are based on.

BH Series Maintenance Schedule

Remind me when maintenance is due
Every 6-12 months
Clean system components

Check the heat sink, air intake, and air outlet for foreign matter or dust. Clean if necessary.

Show in the manual (page 37)
Every 6-12 months
Inspect electrical connections

Check whether cables are securely connected. Inspect for broken cables or exposed copper cores.

Show in the manual (page 37)
Yearly
Verify sealing integrity

Check that all terminals and ports are properly sealed. Reseal cable holes if they are not sealed or too big.

Show in the manual (page 37)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend BH Series?

Yes No

Frequently Asked Questions

A

Connect your device to the Solar-Wi-Fi SSID printed on the label. Open a browser and enter 10.10.100.253 to access the admin panel. Select your home network and enter the password. Ensure the password matches exactly including case sensitivity. Once connected, the LED indicator will turn solid green confirming successful server access.

Is this answer helpful?

A

You can connect standard household appliances. Inductive loads like non-inverter air conditioners up to 1.5 horsepower are permitted. Capacitive loads must remain below sixty percent of the nominal power rating. Avoid devices with high start-up surges such as large pumps or frequency converters that could trigger overload protection prematurely.

Is this answer helpful?

A

This usually occurs when BMS communication fails temporarily during lithium battery operations. It also happens when batteries enter float charge mode where the state of charge resets automatically. Check the communication cables between the inverter and the battery controller to resolve persistent discrepancies in reported levels.

Is this answer helpful?

A

No, you cannot substitute other brands of meters. The communication protocol is specifically integrated into the GoodWe system for seamless data transfer. Using incompatible meters will cause communication failures and prevent proper power limiting or export control functions from working correctly.

Is this answer helpful?

A

The automatic switching time is less than ten milliseconds. This speed classifies the system as a UPS-level backup solution for most sensitive electronics. Ensure critical loads do not depend on absolute zero interruption continuity as some very high-end medical equipment may have stricter requirements.

Is this answer helpful?

A

Following the manual instructions is mandatory for full warranty coverage. While technical support may remain available, replacements or returns are not guaranteed if safety protocols are ignored. Contact the after-sales department before deviating from standard procedures to discuss special conditions safely.

Is this answer helpful?

A

This indicates the open-circuit voltage of your solar panels exceeds the maximum input limit of the inverter. Reduce the number of panels per string to bring voltage down. Alternatively, check if the battery voltage is too high before connecting the charge controller to avoid triggering DC input protection mechanisms.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • High max efficiency up to 96.6% for superior energy conversion
  • Flexible operation modes adapt to grid or off-grid conditions
  • Supports lithium-ion batteries with active BMS communication
  • Integrated Wi-Fi and Ethernet for remote monitoring access
  • Compact wall-mounted design saves space on property
VS

Disadvantages

  • Requires specialized installation by qualified electricians only
  • Backup function unavailable in certain international markets
  • Strict cable sizing limits prevent generic wire usage
  • Internal fans may generate low audible noise levels
  • Smart meter compatibility restricted to included models
M: QW-35-FL

Product Specification

Note

Prices include 0% VAT rates where applicable for AT and DE

Output Phases

1-phase

Input

BC05

Output

BC05

Ingress Protection

IP65

Ambient Temperature

-31°F to +140°F

M: QW-35-FL

Product Description

Revolutionize Your Home Energy System with Advanced Storage

Achieving true energy independence requires robust hardware capable of managing diverse power sources efficiently and safely. The GoodWe BH-Series stands out as a premier solution for modern households seeking to optimize self-consumption rates and secure uninterrupted backup power availability. This advanced inverter allows users to integrate existing grid-tied solar systems with new battery storage effortlessly without requiring complete replacement of previous renewable investments. Whether you aim to significantly reduce monthly utility costs or prepare effectively for unexpected blackouts during severe weather events, this unit provides the exceptional operational flexibility needed for complex residential energy architectures today.

Intelligent Operation Modes Explained

One of the distinct advantages involves its highly adaptable operational functionality designed to work across various daily usage scenarios. Users can configure the system dynamically to prioritize solar energy usage first before drawing stored energy from batteries or importing necessary electricity from the public grid supply. During normal sunny conditions, excess solar power charges the internal battery while remaining surplus gets exported profitably to the local grid. In scenarios where solar production is weak during cloudy periods, the battery supplements household loads alongside the grid connection automatically. Should a total grid outage occur, the internal relay ensures the system switches to support critical back-up loads almost instantly. These sophisticated behaviors align perfectly with specified guidance found in the comprehensive Goodwe BH-Series (AC-coupled) Manual regarding configuration settings via the SolarGo application interface.

Installation and Long Term Performance

Proper physical setup ensures maximum longevity and operational safety over many years of service life. The unit supports both indoor and outdoor environments due to its impressive high ingress protection rating against dust and water. Installers must mount the device vertically or at a slight angle on solid concrete walls away from any nearby flammable materials or explosive liquids. Adequate surrounding air circulation is absolutely crucial because excessive heat dissipation issues directly affect long-term conversion performance efficiency levels. Electrical wiring connections require extremely careful attention to grounding standards and specific copper cable sizing recommendations outlined in the dedicated installation procedures. Only fully qualified professional electricians should ever perform these potentially dangerous tasks to maintain full warranty validity protections.

Critical Monitoring and Support

Regular remote monitoring through the SEMS Portal helps identify potential electrical faults or performance drops early. Always disconnect all main AC power lines before attempting any local servicing on internal components for personal safety. Ensure the included smart meter communicates correctly with the designated port for optimal export power limiting functions and accurate billing data. LED status lights provide immediate visual feedback on system health including current battery charge states and stable grid connectivity issues. This level of real-time transparency empowers owners to manage assets proactively rather than reactively when problems arise. Firmware updates check regularly on the SolarGo App interface to keep software synchronized with latest features.