Manual.ly Logo

Feldtmann OPTIflex Optimate Manual

0.0 · 0 Ratings

PDF manual · 16 Pages

English

M: OA-GPT-5-NAN
page

/ 16

Loading...
723cd43055ed76c1e47fb3eec17d9b0a29ec page 4
ABCDE
ABCDEF
Test
A
B
C
D
E
F
E = Cut resistance according to
EN ISO 13997:1999 (N)
2
5
10
15
22
30
Manufacturer information according to Regulation (EU) 2016/425, Appendix II, Section 1.4 (reference in the Official Journal of the
European Union.)
PSA category 2
Sizes: 05 - 12
Please read carefully before use! You are obligated to include this user information when passing on the personal protective equipment (PPE) or to hand it
over to the recipient. For that purpose, this user information can be reproduced in unlimited quantities and downloaded at www.feldtmann.de.
Markings on the gloves
= These gloves are certified as personal protective equipment (PPE). The CE symbol shows that this product meets the requirements of
Regulation (EU) 2016/425. The Declaration of Conformity can be found at www.feldtmann.de/Konformitaetserklaerungen
= the manufacturer’s information must be
observed!
= date of production see CE Label
Clarification and numbers of standards whose requirements the gloves meet
Reference to the standards: Official Journal of the European Union. Available from Beuth Verlag GmbH, 10787 Berlin. www.beuth.de.
EN ISO 21420:2020 Protective gloves. General requirements and test method
EN 388:2016 Protective gloves against mechanical risks must achieve performance level 1 or performance level A of the TDM cut resistance test
according to EN ISO 13997:1999 for at least one of the properties (abrasion resistance, cut resistance, tear resistance and puncture resistance).
Performance levels refers to the palm of the glove. Abrasion resistance: The number of rotations required to wear through the test glove. Cut resistance: The
number of test cycles it takes to cut through the test sample at a constant speed. Tear resistance: The force necessary to continue tearing the cut test
sample
Puncture resistance: The force required to punch through the test sample using a standardized test point.
The higher the number, the better the test result. X means “not tested”.
P means “passed”.
EN 407:2020 Safety gloves for thermal risks
The mark "X" instead of a number means that the gloves are not intended
for the use covered by this test.
WARNING: If the gloves have performance level 1 or 2 for combustion behavior, the gloves must not come into contact with open flame.
For multilayer gloves whose layers can be separated from one another, the performance levels apply only in relation to the entire glove, including all layers.
This glove offers additional protection on contact with hot objects according to the aforementioned performance level results.
General instructions
This user information is intended as assistance in selecting your safety equipment. Laboratory tests offer help in choosing, but they cannot evaluate the
conditions of the actual workplace. The performance levels are based on the results of laboratory tests that may not reflect the actual conditions at the workplace.
The user, and not the manufacturer, is therefore responsible for checking the suitability of a specific glove for the planned application.
Purpose, application and risk evaluation
This glove is suitable only for universal applications with slight mechanical risks. The following applies to all gloves with a tear resistance of level 1 or higher:
If there is a risk of being pulled in by rotating machine parts no gloves must be worn. No protection against pointed objects, such as injection needles. This
glove offers additional protection when in contact with warm objects according to the performance level mentioned above.
For questions or when in doubt about the range of use for these gloves, contact the company safety officer, supplier or manufacturer.
Cleaning and care
Treatment with ordinary commercially available cleaning products is recommended (such as brushes, polishing cloths, etc.). Washing or chemical cleaning
requires prior consultation with a recognized specialist company. The manufacturer accepts no liability for changes in the product’s properties. Before reuse,
the gloves must always be checked to ensure they are intact. The same applies to the protective effect according to the specified performance levels.Evaluation
with the aforementioned performance levels is based on tests of unused gloves. Transfer of the results to gloves after care treatment requires appropriate
testing.
Packaging, storage and disposal
This item is delivered in standardized sales packaging made of recyclable cardboard. The smallest packaging unit is located in PE bags or similar
environmentally friendly enclosures. The gloves must be properly stored, i.e. boxed and in dry rooms. Influences such as humidity, temperature, light and
natural material changes during a given period may change the product’s protection properties. No expiration date can be indicated, because it would depend
on the degree of wear and use, and on the application. Dispose of the product according to local regulations.
Material composition / the product consists of
97% polyamide, 3% elasthane, grey / Nitrile, waterbased polyurethane; black
Health restrictions
During proper work with the product, allergic reactions may arise to components of the glove. If allergic reactions occur, stop using the gloves and seek
medical attention.
Name and address of manufacturer
HELMUT FELDTMANN GmbH
Zunftstraße 28
D-21244 Buchholz/Nordheide
www.feldtmann.de
Test
1
2
3
4
5
A = Abrasion resistance
(number of rubs)
100
500
2000
8000
-
B = Cut resistance (index)
coupe test
1,2
2,5
5,0
10,0
20,0
C = Tear resistance (N)
10
25
50
75
-
D = Puncture resistance
(N)
20
60
100
150
-
Test criteria
Evaluation
0680
A = Abrasion resistance
0 - 4
4
B = Cut resistance (coupe test)
0 - 5
1
C = Tear resistance
0 - 4
3
D = Puncture resistance
0 - 4
1
E = Cut resistance (TDM)
according to EN ISO 13997:1999
A - F
A
Prüfungskriterien
Bewertung
0680
A = Burning behaviour
0 - 4
X
B = Contact heat
0 - 4
1
C = Convective heat
0 - 4
X
D = Radiant heat
0 - 4
X
E = small splashes of
molten metal
0 - 4
X
F = large amounts of
molten metal
0 - 4
X
Test
1 2 3 4
Combustion behavior: Burning time (s)
Glowing time (s)
≤20 ≤10 ≤3 ≤2
- ≤120 ≤25 ≤5
Contact heat (°C)
Threshold time (s)
100 250 350 500
≥15 ≥15 ≥15 ≥15
Convective heat: Heat protection index HTI
(s)
≥4 ≥7 ≥10 ≥18
Radiant heat: Heat transfer t
3
(s)
≥5 ≥30 ≥90 ≥150
small splashes of molten metal — number of
drops
≥5 ≥15 ≥25 ≥35
large amounts of liquid metal — Liquid iron (g)
30 60 120 200
Notified body responsible for performing the type examination:
MIRTA KONTROL d.o.o.
Javorinska 3
HR-10040 Zagreb - Dubrava
Notified Body No.: 2474
- 2 -

Chat with your Feldtmann OPTIflex Optimate manual using AI

Get instant AI answers from your Feldtmann OPTIflex Optimate manual

Ask anything about the Feldtmann OPTIflex Optimate. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend OPTIflex Optimate?

Yes No

Frequently Asked Questions

A

The gloves are made of 97% polyamide (nylon) and 3% spandex with a grey nitrile and black water-based polyurethane (PU) coating on the palm and fingertips for grip and durability.

Is this answer helpful?

A

They comply with EN ISO 21420:2020 (general glove requirements) and EN 388:2016 (mechanical risks). The product is CE marked as PPE category 2 and the Declaration of Conformity is available on the manufacturer website.

Is this answer helpful?

A

No. Cut resistance is modest (Coupe test level 1, TDM class A) and puncture resistance is low (level 1). They are intended for light mechanical risks and not for heavy cut or needle protection.

Is this answer helpful?

A

Use common cleaners like brushes or cloths. Washing or chemical cleaning requires consultation with a specialist because such treatments can change protective properties. Store boxed in dry rooms away from moisture, heat and direct light.

Is this answer helpful?

A

No. EN 407 thermal test results include many parameters marked X (not intended). If gloves have combustion behavior level 1 or 2 they must not contact open flames; they only offer limited contact heat protection.

Is this answer helpful?

A

These gloves are produced in sizes 05–12. Select the size that provides a snug fit without restricting movement; check manufacturer size guidance or try samples where possible.

Is this answer helpful?

A

Stop using the gloves immediately and consult a medical professional. Allergic reactions to glove components can occur even with correct use.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High abrasion resistance (EN 388 level 4) for long wear in light-mechanical tasks.
  • Good dexterity and fit thanks to 97% polyamide / 3% spandex construction.
  • PU/nitrile coating provides improved grip on dry and slightly oily surfaces.
  • Wide size range (05–12) fits many users and job types.
  • CE certified; complies with EN ISO 21420 and EN 388 standards.
VS

Disadvantages

  • Limited cut resistance (Coupe test level 1; TDM class A) — not for heavy-cut risks.
  • Low puncture resistance (level 1) — not suitable where needle or sharp-object protection is required.
  • Thermal protection limited (contact heat level 1; many EN 407 items marked X).
  • Cleaning/washing may alter protective properties; professional advice needed for laundering.
  • No fixed expiration — lifespan depends on wear and usage, requiring frequent inspections.
M: OA-GPT-5-NAN

Product Specification

Color

yellow, black

Material

Nylon, Spandex

Features

Coating, washable (up to 104°F), non-slip, breathable

M: OA-GPT-54-NAN

Product Description

Feldtmann OPTIflex Optimate Arbeitshandschuhe Manual

Feldtmann OPTIflex Optimate work gloves blend modern materials and tested protective performance for everyday industrial and light mechanical tasks. Designed for universal applications with light mechanical risks, these gloves target users who need reliable grip, comfort and basic heat contact protection without heavy-duty cut or puncture resistance.

Made of 97% polyamide (nylon) and 3% spandex with a grey nitrile and black water-based polyurethane coating, the OPTIflex Optimate gloves emphasize dexterity and a close fit. The breathable knit shell keeps hands agile and reduces fatigue during extended wear, while the PU/nitrile coating on the palm and fingertips improves grip on dry and slightly oily surfaces. Sizes range widely from 05 to 12, covering most hand sizes for workshop, assembly, maintenance and general handling tasks.

These gloves meet relevant standards: EN ISO 21420:2020 for general glove requirements and EN 388:2016 for mechanical risk performance metrics. Test ratings indicate high abrasion resistance (level 4), modest cut resistance by coupe test (level 1) and TDM cut class A, tear strength level 3 and puncture resistance level 1. EN 407 thermal tests show limited performance: contact heat level 1 and other thermal parameters marked as not intended or not tested (X). The product carries CE marking and a Declaration of Conformity is available from the manufacturer.

Practical care instructions recommend routine cleaning with common cleaning agents (brushes, cloths); washing or chemical cleaning should be cleared with a specialist as such treatments can alter protective properties. Always inspect gloves before reuse. Store in dry boxes away from moisture, direct light and extreme temperatures; there is no fixed expiry date since useful life depends on wear and application. Dispose according to local regulations.

Health considerations note possible allergic reactions to glove components; discontinue use and consult a physician if sensitivity occurs. For any doubt about suitability for specific tasks, contact your company safety officer, supplier or the manufacturer HELMUT FELDTMANN GmbH.

Notes

  • Certified as PPE, category 2, CE marked. Declaration of Conformity: www.feldtmann.de/Konformitaetserklaerungen
  • Not intended for protection against sharp needles or for use where open flames are present if combustion rating is 1 or 2.
  • Performance levels are based on laboratory testing of unused gloves; results may change after cleaning or during real workplace use.
M: OA-GPT-5-NAN

© Copyright 2026 Manual.ly