GETTING STARTED WITH THE MACHINE
• IMPACT WRENCHES SHOULD ONLY BE USED FOR TIGHTENING AND LOOSENING
FILLETED FIXING ELEMENTS. FACOM WILL NOT BE LIABLE IF THE MACHINE IS USED
FOR ANY OTHER PURPOSE.
THIS MACHINE HAS NOT BEEN DESIGNED TO BE USED IN AN EXPLOSIVE
ATMOSPHERE.
This machine and its accessories must be used in compliance with these instructions.
Using it for any other purpose may cause a risk of danger for people and the
environment.
• Always operate, inspect and maintain this machine in accordance with all
regulations (local, state, federal and country), that may apply to hand held/hand
operated pneumatic machine.
• For safety, top performance, and maximum durability of parts, operate this
machine at 90 psig (6.2 bar/620 kPa) maximum air pressure at the inlet with
3/8” (10 mm) inside diameter air supply hose.
• Exceeding the maximum pressure of 6.2 bar will lead to the risk of danger such
as excessive speed, breaking parts, higher torque or force that may destroy the
machine and its accessories or the part being worked on.
• Be sure all hoses and fittings are the correct size and are tightly secured.
• Always use clean, dry and lubricated air at 90 psig maximum air pressure. Dust,
corrosive fumes and/or excessive moisture can ruin the motor of an air machine.
• Do not lubricate machine with flammable or volatile liquids such as kerosene,
diesel or petrol.
• Do not remove any labels. Replace any damaged label.
• The use of a hose whip is recommended. A coupler connected directly to the air
inlet increases tool bulk and decreases tool maneuverability.
• The pneumatic machine must be fitted and connected to the compressed air
network via quick disconnects to facilitate shutdown in the event of danger.
• When the life of the tool has expired, it is recommended that the machine be
disassembled, degreased and parts be separated by material so that they can be
recycled.
USING THE MACHINE
• Before using the machine, check that there is no dangerous interaction with
the immediate environment (explosive gas, inflammable or dangerous liquid,
unknown piping, electric sheathing or cable, etc).
• Before connecting the machine to the air inlet, check the trigger is not blocked in
the on position by an obstacle and no adjustment or assembly tool is still in position.
• Check the machine is connected to the network by a quick disconnect joint and
that an air braker valve is close by to shut the air down immediately in the event
of blockage, breakage or any other incident.
• Keep hands, loose clothing and long hair away from rotating end of machine.
• Check the position of the inversion system before starting the machine.
• Anticipate and be alert for sudden changes in motion during start up and
operation of any power machine.
• Ensure that the unit on which the work is being carried out is immobilised.
• In the event of blockage, release the trigger and disconnect the machine
from the compressed air network.
• Use accessories recommended by FACOM.
• The use of other than genuine FACOM replacement parts may result in safety
hazards, decreased machine performance, and increased maintenance, and cancel
all warranties.
Repairs should be made only by authorized trained personnel. Consult your
nearest FACOM Authorized Servicenter.
Do not use damaged, frayed or deteriorated air hoses
and fittings.
The pneumatic
machine can vibrate in use. Vibration, repetitive
motions or uncomfortable positions may be harmful to your hands
and arms. Stop using any machine if discomfort, tingling feeling
or pain occurs.
Seek medical advice before resuming use.
Do not carry the machine by the hose.
Keep body stance balanced and firm. Do not overreach when
operating this
machine
.
Do not use the machine under the influence of drugs, alcohol,
medication or if you are tired.
Use protective equipment such as glasses, gloves, safety shoes as well
as acoustic protection.
Remain vigilant, use common sense and pay attention when using
the machine.
Always turn off the air supply and disconnect the airsupply hose
before installing, removing or adjusting any accessory on this
machine
, or before performing any maintenance on this
machine
.
This pneumatic machine must not be used for hitting as it may
damage safety elements and cause breakage.
WARNING

Chat with your Facom NK.2000F2 manual using AI

Get instant AI answers from your Facom NK.2000F2 manual

Ask anything about the Facom NK.2000F2. Answers come from this manual, with the pages they are based on.

NK.2000F2 Maintenance Schedule

Remind me when maintenance is due
Every 3-5 months
Lubricate internal mechanism

Inject 4 grams of FACOM grease into rear fitting every 3-5 months depending on use using recommended nozzle tip.

Before and after each use
Lubricate air tool manually

Disconnect from air, depress trigger, add 0.15-0.25 ml oil to inlet, then run for 2-3 seconds with exhaust covered.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend NK.2000F2?

Yes No

Frequently Asked Questions

A

The NS.3500G is the highest-torque model listed, producing up to 1898 Nm of breakaway torque. It is intended for demanding fastening and removal tasks involving stubborn nuts and bolts.

Is this answer helpful?

A

Operate each model at a maximum inlet pressure of 6.2 bar, 620 kPa, or 90 psig. Higher pressure can cause excessive speed, wear, increased force, component damage, and unsafe operating conditions.

Is this answer helpful?

A

The NS.2500G is the compact option. It weighs 1.4 kg and measures 144 x 62.5 x 197 mm, making it easier to handle where space or operator fatigue is a concern.

Is this answer helpful?

A

No. Use only impact-rated sockets, extensions, and accessories recommended for pneumatic impact tools. Chrome sockets and ordinary hand-tool sockets may crack or fail under impact loads.

Is this answer helpful?

A

Lubricate the air tool before first use and before and after subsequent use. Add 0.15 to 0.25 ml of air tool oil at the inlet. Apply 4 g of approved impact grease to the internal mechanism every three to five months, depending on use.

Is this answer helpful?

A

The removable LED accessory is USB rechargeable and must be charged before first use. Two LEDs illuminate the area around the square drive when the trigger is pressed, then turn off after about 20 seconds. A full charge takes four hours or less.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Three 1/2-inch models cover high-torque, general-purpose, and compact fastening needs.
  • NS.3500G provides up to 1898 Nm breakaway torque for difficult fasteners.
  • Variable-speed trigger and three forward speed settings support controlled tightening.
  • Compact NS.2500G weighs 1.4 kg while offering 950 Nm breakaway torque.
  • USB-rechargeable LED accessory improves visibility around the immediate work area.
VS

Disadvantages

  • Requires a clean, dry compressed-air system and a suitable 10 mm internal-diameter hose.
  • Daily oiling and periodic internal greasing are necessary to preserve tool life.
  • Noise levels reach 93 to 95 dB(A), so hearing protection is essential.
  • Reverse operation is always full power, which may reduce fine control during removal.
  • Only impact-rated Facom-recommended sockets and extensions should be used.
M: gpt-5.6-terra

Product Specification

Type

Impact wrench

Operating pressure

89.92 psi

M: gpt-5.6-terra

Product Description

Facom Pneumatic Impact Wrench Manual: Power for Demanding Fasteners

The Facom Pneumatic Impact Wrench range is built for professional fastening work where speed, control, and dependable air-powered performance matter. Covering the NS.3500G, NS.3100G, and compact NS.2500G models, these 1/2-inch square-drive tools are designed to tighten and loosen threaded fasteners such as nuts and bolts when paired with properly rated impact sockets.

Choose the Right Level of Torque

Each model serves a distinct workload. The NS.3500G delivers the highest breakaway torque in the range at 1898 Nm, making it a strong choice for stubborn, heavily tightened fasteners. The NS.3100G provides 1600 Nm of breakaway torque in a similar full-size format. For work where access and lower weight are priorities, the NS.2500G combines a compact body with 950 Nm of breakaway torque and a maximum speed of 10,000 rpm.

All three wrenches operate at a maximum air pressure of 6.2 bar, or 90 psig. They require clean, dry compressed air and perform best with a 10 mm internal-diameter air supply hose. Average air consumption is 172 l/min for the NS.3500G and NS.3100G, while the NS.2500G uses 167 l/min.

Trigger Control and Practical Lighting

The variable-speed trigger gives the operator direct control over tool speed. Forward operation can be selected through three speed settings, while reverse runs at full power for efficient removal work. Before using the wrench, confirm that the direction control matches the task and that the socket, extension, and retaining components are securely fitted.

A removable USB-rechargeable LED light accessory surrounds the square drive to illuminate the immediate fastening area. The lights activate when the trigger is pressed and switch off after approximately 20 seconds. The accessory should be fully charged before its first use, with a typical full charge taking four hours or less.

Safe Operation and Routine Care

The Facom Pneumatic Impact Wrench Manual emphasizes safe, disciplined use. Wear eye protection, hearing protection, gloves, safety footwear, and respiratory protection when conditions require it. Keep hands clear of the socket and allow room behind the tool when loosening fasteners, since the wrench can move as the fastener backs off.

Disconnect the air supply before changing accessories or performing maintenance. Use only impact-rated sockets and extensions recommended for pneumatic impact use. Daily lubrication is essential because moisture in compressed air can damage internal components. Add 0.15 to 0.25 ml of air tool oil before initial use and before and after later use. Internal impact grease should be renewed with approved Facom grease every three to five months, based on workload.

Note: Do not exceed 6.2 bar air pressure, use damaged hoses, or operate the wrench with unsuitable accessories. Proper air filtration, lubrication, and inspection help protect performance and service life.