Utilisation - Use - Gebrauch - Gebruik - Utilización - Uso - Sposób uzycia
Pour la série 208 Réglage au couple souhaité Pour la série 248
Conseils
• Utiliser le tableau des couples de serrages conseillés situé en fin de notice. • L'unité de mesure normalisée est le Newton mètre, symbole "Nm".
1 mètre kilo = 9,81 Nm
(environ 10 Nm)
. 1 ft/lb = 1,35 Nm. 1 in/lb = 0,1128 Nm. 1 in/oz = 0,00705 Nm.
1 Nm = 0,102 mètre kilo
(environ 100 g/m)
1 Nm = 0,738 ft/lb. 1 Nm = 8,863 in/lb. 1 Nm = 141,8 in/oz.
• Ne jamais dépasser le couple maximum de votre clé, en particulier en cas de déblocage et ou de serrage angulaire.
• Pour prolonger la durée de vie de votre outil dynamométrique, il est préférable de le règler à la capacité minimum avant de le ranger.
Entretien
• Utiliser un chiffon sec pour nettoyer votre clé, n'utiliser ni solvant ni détergent.
• Ne pas démonter votre clé.
Serrage
A •Placer votre clé perpendiculaire à l'axe de serrage.
B •Placer la main au milieu de la poignée.
C • Tirer progressivement et perpendiculairement à la
clé.
D •Au déclenchement "Clic" stopper immédiatement
votre effort.
Maintenance de la précision
• Il est conseillé de faire vérifier votre clé périodiquement
(environ tous les ans ou plus souvent pour une utilisation intensive)
et, en cas de chute, sur un appareil de
contrôle, ou par le laboratoire de métrologie FACOM.
Vérification de la précision et mise à jour des documents :
• Le laboratoire de métrologie FACOM établit sur demande des constats de vérification ou des certificats d'étalonnage.
Pour la série 208. Constat de vérification :
Contrôle et réglage s'il y a lieu à 20, 60 et 100% de la capacité de la clé,
dans les tolérances de la norme.
Etablissement d'un constat daté et numéroté.
Certificat d'étalonnage : Contrôle et réglage de la clé sur 6 à 12
points, avec des appareils raccordés à l'étalon national de mesure.
Etablissement d'un certificat officiel daté et numéroté.
Pour de plus amples informations : Consultez votre distributeur.
Pour la série 248. Constat de vérification :
Contrôle et réglage s'il y a lieu de la répétabilité approximativement à 20, 60
et 100% de la capacité de la clé, dans les tolérances de la norme.
Etablissement d'un constat daté et numéroté.
Pré-réglage : Réglage au couple désiré et vérification de la répétabilité.
Etablissement d'un constat daté et numéroté.
En France pour tous renseignements techniques sur l'outillage à main, téléphonez au : 01 64 54 45 14
F
1 •Tirer la bague vers la poignée.
2 •Tourner la poignée et arrêter le vernier
sur la graduation souhaitée.
3 •Lacher la bague qui s'encliquete.
1 •Dévisser le bouchon b et introduire une clé
mâle à l'arrière de la clé.
2 •Avec un appareil de contrôle, régler votre clé
au couple souhaité. Visser pour augmenter le
couple, dévisser pour le diminuer.
3 •Retirer la clé mâle et revisser le bouchon b.

Chat with your Facom J.S.208D manual using AI

Get instant AI answers from your Facom J.S.208D manual

Ask anything about the Facom J.S.208D. Answers come from this manual, with the pages they are based on.

J.S.208D Maintenance Schedule

Remind me when maintenance is due
Yearly
Verify precision and calibration

Have the wrench checked on a test rig or by the FACOM metrological laboratory every year, or more often for intensive use.

After drop
Check after dropping

If the tool is dropped, verify it immediately using a test device or send to the FACOM metrology lab.

Every use
Clean with dry cloth

Wipe the wrench with a dry cloth only. Do not use solvents or detergents.

Every use
Store at minimum setting

Set the torque wrench to its minimum capacity before storing it in its case.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend J.S.208D?

Yes No

Frequently Asked Questions

A

It is used for tightening fasteners to a preset torque value, helping ensure accurate and repeatable results. It is ideal for workshop, maintenance, and assembly tasks where controlled fastening matters.

Is this answer helpful?

A

The click indicates that the selected torque has been reached. At that point, tightening should stop immediately to avoid overtightening and possible damage to the fastener or part.

Is this answer helpful?

A

The 14x18mm fitting provides compatibility with matching heads or accessories, giving the wrench more flexibility for different applications and tool setups.

Is this answer helpful?

A

It should be returned to its minimum torque setting before storage. This helps preserve the spring mechanism and supports long-term accuracy.

Is this answer helpful?

A

Regular checking is recommended, typically about once a year, or more often if the tool is used heavily or has been dropped. Calibration helps keep results consistent.

Is this answer helpful?

A

Use a dry cloth only. Avoid solvents, detergents, and disassembly, as these can affect the tool’s condition and precision.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Accurate tightening with clear click feedback for controlled stops.
  • 14x18mm compatibility supports flexible use with matching accessories.
  • Manual adjustment keeps operation simple and practical in daily work.
  • Built for repeatable torque application, helping reduce overtightening.
VS

Disadvantages

  • Must be used carefully to stay within the maximum torque limit.
  • Requires periodic calibration to maintain precision over time.
  • Should not be dismantled, which limits user-side servicing.
  • Needs proper storage at minimum setting to protect accuracy.
M: OA-GPT-54-NAN

Product Specification

Tool Mount

0.55x0.71in Insert Square

Torque

29.50-147.51 lb-ft

Handle

Plastic

Overall Length

18.35in

Special Features

interchangeable head

M: OA-GPT-54-NAN

Product Description

Facom J-S.208D Torque Wrench 14x18mm Manual

The Facom J-S.208D Torque Wrench 14x18mm Manual is built for users who need controlled tightening with reliable repeatability. Designed around Facom’s trusted torque-wrench philosophy, it helps reduce guesswork and supports precise assembly work where fastening accuracy matters. Whether you are handling mechanical maintenance, workshop tasks, or regular service jobs, this wrench brings a professional level of consistency to every turn.

One of the standout qualities of this model is its focus on accuracy and control. The wrench is intended to work within a defined torque range and delivers a clear click signal when the preset value is reached. That audible and tactile feedback is especially useful in busy environments, because it tells you exactly when to stop applying force. The result is safer fastening, less risk of overtightening, and better protection for both the fastener and the component.

The 14x18mm fitting also adds versatility. It allows the wrench to be paired with compatible heads and accessories, making it a practical choice for professionals who need one tool to adapt to different applications. The manual adjustment system is straightforward, so users can set the desired torque with confidence and keep working efficiently without unnecessary complexity.

Facom also emphasizes proper handling and long-term care. The wrench should be cleaned with a dry cloth, stored at the minimum setting, and checked periodically to maintain its precision. That approach may sound simple, but it reflects what makes a good torque tool valuable over time: stable performance, dependable calibration, and consistent results when precision cannot be compromised.

For anyone looking for a dependable tightening solution, this model offers a balanced mix of durability, usability, and control. It is a strong fit for technicians who value accuracy and prefer tools that perform predictably under daily workshop conditions.

Notes

  • Use the wrench within its rated torque range.
  • Store it at minimum setting after use.
  • Periodic calibration helps preserve accuracy.
  • Avoid solvents and disassembly during cleaning.