Manual.ly Logo

Ergotron StyleView SV41 Manual

0.0 · 0 Ratings

PDF manual · 14 Pages

English

M: claude-opus-5-5
page

/ 14

Loading...
b724d103726e379afa2f9d47ab2be1191615 page c
12 of 14
888-24-377-W-00 rev. A • 11/17
ENGLISH
Recommended Periodic Inspection and Maintenance
Component Action How often By whom
UI, Ethernet, USB
cables
Inspect for wear, pinching, bad connectors Monthly Any user
Fan on side of CPU
compartment
Inspect for dust at intake, vacuum as required using a vacuum cleaner that DOES NOT generate
ESD (Electrostatic Discharge)
Monthly Any user
Casters Inspect for wear and debris Monthly Any user
Maximum Load Inspect to ensure that maximum recommended loads are not exceeded Daily Any user
1. Please dispose of all batteries in accordance with local law
2. Always replace with similar size battery (33 A-h to replace 33 A-h) and always replace in pairs
Cleaning and Maintenance
The following procedures are not guaranteed to control infection. The hospital infection control administrator or epidemiologist should be consulted regarding cleaning procedures
and processes.
To avoid risk of electric shock, do not expose electrical components to water, cleaning solutions or other potentially corrosive liquids or substances.
Do not immerse Cart or Cart components in liquid or allow liquids to  ow into the Cart. Wipe all cleaners o surface immediately using a damp cloth. Thoroughly dry surface
after cleaning.
Do not use  ammable cleaners on Cart surfaces due to close proximity of electrical power and equipment.
All paints and plastic Cart components will withstand cleaning by most commonly used, diluted, non-abrasive solutions such as quaternary ammonia compounds, ammonia
enzyme cleaners, bleach or alcohol solutions.
• Pen and permanent and dry erase markers can be removed with 91% isopropyl alcohol and a soft cloth.
• Iodine stains can be removed with commonly used cleaners and a soft cloth.
• Never use steel wool or other abrasive materials that will damage the surface  nish.
• Do not use strong solvents such as trichloroethylene and acetone. These solvents will damage the surface  nish.
It is recommended that any cleaning solution be tested on a small, inconspicuous area to ensure surface is not harmed.
Adjustment, Service, Replacement - DO NOT attempt to adjust, service or replace any part of the StyleView Cart unless directed to do so through Ergotron-approved
documentation (i.e. installation instructions). Only Ergotron, Inc. or an Ergotron-certi ed entity may adjust, service or replace StyleView Cart components. If any component on the
Cart is missing or damaged, the Cart must not be used, contact Ergotron Customer Care immediately to request a replacement part.
Cables - Keep cables neatly organized on the Cart (a variety of solutions are provided with your cart for this purpose). Excess cables should be routed away from moving
components with cable clips. Review Cable Routing section of this guide, or contact Ergotron Customer Care for more information.
Casters - Check casters periodically to make sure they are clean and free of debris that would prevent smooth travel. Avoid moving Cart across uneven, dirty or damaged
surfaces.
Customer Equipment- Make sure equipment is balanced and mounted securely to Cart. Do not reposition Cart components on riser or tower unless instructed to do so in the
installation instructions. Moving Cart components too high or too low on the Riser may create an unstable condition, leading to equipment damage or even personal injury. Contact
Ergotron Customer Care for information about moving Cart components.
Safety Alerts Associated with this Product
The following Warnings/Cautions appear in this reference guide or on the cart:
NOTE: Failure to adhere to these guidelines may result in equipment damage or personal injury.
CAUTION: The lift brake helps stablilize the worksurface and keyboard tray during normal use but it DOES NOT increase load capacity. DO NOT load riser with equipment
totaling more than the maximum weight capacity speci ed by Ergotron. Ensure optimum lift function by testing and if necessary, re-adjusting tension whenever the weight
mounted to the riser changes (i.e., equipment is removed or added). See "Set Riser Lift Tension" adjustment instructions.
CAUTION: Do not operate StyleView Cart with missing or damaged components! Do not remove, modify or substitute Cart components without consulting Ergotron. If you
encounter problems with Cart installation or operation, contact Ergotron Customer Care.
CAUTION: DO NOT overtighten fasteners. Overtightening may cause damage to your equipment.
WARNING: Stored Energy Hazard: The worksurface lift mechanism is under tension and will move up rapidly, on its own, as soon as attached equipment is removed. For this
reason, DO NOT remove equipment unless the worksurface has been moved to the highest position on the tower! Failure to follow this instruction may result in serious personal
injury and/or equipment damage! When Shipping the cart, set the worksurface lift mechanism to the lowest tension setting.
CAUTION: DO NOT loosen, tighten or remove any other nuts or bolts on the riser or top of tower. Tampering with nuts or bolts may result in an unstable Cart, leading to
equipment damage and/or personal injury.
CAUTION: Release Lift Brake before moving work surface! Moving work surface while Lift Brake is engaged may cause serious damage to Lift Engine.
WARNING: In the event that repair of the StyleView Cart is needed, contact Ergotron Customer Care immediately. Cart repair can only be performed by Ergotron, Inc. or by an
Ergotron authorized agent.
WARNING: This cart is not intended for use in a  ammable, anesthetic mixture or oxygen rich environment.
Con guration & Safety
Additional multiple socket-outlet or extension cord shall not be connected to the medical system.
When used in a Medical Electrical system, connect only equipment that complies with IEC, ISO, UL/ANSI, or CSA standards that are relevant to that equipment.
Risk of shock or personal injury when connecting non-medical equipment supplied as part of a system directly to the wall outlet when non-medical equipment is intended to
be supplied by the multiple socket outlet.
Risk of shock or personal injury when connecting any equipment that has not been supplied as part of the medical system to the multiple socket outlet.
Maintenance & Safety

Chat with your Ergotron StyleView SV41 manual using AI

Get instant AI answers from your Ergotron StyleView SV41 manual

Ask anything about the Ergotron StyleView SV41. Answers come from this manual, with the pages they are based on.

StyleView SV41 Maintenance Schedule

Remind me when maintenance is due
Daily
Inspect maximum load

Ensure that maximum recommended loads are not exceeded.

Show in the manual (page 12)
Monthly
Inspect UI, Ethernet, USB cables

Check for wear, pinching, or bad connectors.

Show in the manual (page 12)
Monthly
Inspect fan on CPU compartment

Check for dust at intake and vacuum as required using a non-ESD vacuum cleaner.

Show in the manual (page 12)
Monthly
Inspect casters

Check for wear and debris to ensure smooth travel.

Show in the manual (page 12)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend StyleView SV41?

Yes No

Frequently Asked Questions

A

Release the brake engagement fully before raising or lowering the cart. Adjust the tension settings based on the mounted equipment weight to ensure smooth movement. Follow the step-by-step instructions in the manual to loosen or tighten specific knobs for the desired position.

Is this answer helpful?

A

The combined weight of the LCD and CPU must not exceed twenty-seven pounds. If the combined weight is greater, the CPU must be mounted to the rear using a separate holder accessory. Do not exceed the maximum recommended loads specified by the manufacturer.

Is this answer helpful?

A

Yes, release the brake before moving the riser and lower the worksurface to the lowest position for optimal stability. Unlock front casters before pushing. Avoid moving the cart with drawers or the worksurface open to prevent tipping hazards.

Is this answer helpful?

A

Wipe all cleaners off the surface immediately using a damp cloth. Thoroughly dry the surface after cleaning. Use common diluted non-abrasive solutions like quaternary ammonia compounds or alcohol. Do not use strong solvents or steel wool.

Is this answer helpful?

A

Always lower the cart before moving it to avoid tipping. Watch for moving parts that can crush or cut. Do not remove equipment at the top height without securing the mechanism. Always follow instructions to mitigate risk of personal injury.

Is this answer helpful?

M: qwen/qwen3.5-flash-20260224

Advantages and Disadvantages

Advantages

  • Height-adjustable LCD mount compatible with standard interfaces
  • Secure storage for laptops and CPU with cable management
  • Front locking casters prevent unintended movement
  • Ergonomic adjustments reduce neck and wrist strain
  • Built-in brake handle for smooth height adjustment and stability
VS

Disadvantages

  • Maximum combined weight limit of twenty-seven pounds for LCD and CPU
  • Tipping hazard if cart is moved at maximum height without lowering
  • Requires manual tension adjustment after changing equipment weight
  • Strict safety warnings regarding moving parts and impact hazards
  • Cleaning requires specific non-abrasive solutions to avoid damage
M: qwen/qwen3.5-flash-20260224

Product Specification

Type

Mobile Workspace

Shape

Rectangular

Material

Desktop: Plastic, Frame: Steel/Aluminum

Color

Desktop: Gray, Frame: Gray

Desktop Dimensions (WxD)

22.36 x 20.98 in

Desktop Height

30.98 - 50.98 in

Desktop Height Adjustable

Electric

Table Legs

4 Feet (4 Casters)

Storage

N/A

Weight Capacity

26.90 lbs

Features

Cable Management, Monitor Mount, Keyboard Tray

Weight

70.55 lbs

Manufacturer Warranty

5 Years

M: qwen/qwen3.5-flash-20260224

Product Description

Advanced Mobile Workstation Solutions

The Ergotron StyleView SV41 Presentation Cart With Monitor Arm And Extendable Work Surface Electrically Height-Adjustable Mobile Workstation 57x53cm Grey/Grey Manual represents a significant step forward in mobile medical and office technology. This comprehensive guide details how to utilize the cart effectively for Electronic Medical Records. It is crucial for hospitals and clinics seeking stability and flexibility. The design focuses on reducing physical strain on healthcare workers while ensuring data security for portable devices.

Critical Specifications

This unit features a height adjustable LCD mount compatible with most standard mounting interfaces. The worksurface provides locked storage for laptops or thin clients. It also includes a storage basket and rear handle for added utility during transport. Cable management is built-in to keep power supplies tidy and prevent tripping hazards in busy hallways. A front handle and rear handle facilitate easy pushing and pulling. The casters on the front can be locked to prevent movement during use. Dimensions vary but generally support a wide range of equipment.

Ergonomic Adjustments

To maximize comfort, lift or lower the riser so the screen sits slightly below eye level. Tilt the display to minimize glare and reduce neck strain. Adjust the worksurface angle to keep wrists flat and elbows bent at ninety degrees. If movement is difficult, follow the tension adjustment instructions found on page ten. This ensures the cart stays in the desired positions without drifting during patient care. The independent LCD lift can be stopped with a screw for heavier displays.

Safety Protocols

Safety is paramount in a clinical environment. Lower the cart before moving to avoid tipping hazards associated with maximum height. Release the brake engagement fully before raising or lowering the unit. Be cautious of moving parts that can crush or cut fingers. Do not exceed the combined LCD and CPU weight limit of twenty-seven pounds. If weight increases, re-adjust the tension settings immediately after installation. Stored energy in the lift mechanism requires caution if equipment is removed at top height.

Maintenance Tips

Inspect cables and casters monthly for wear or debris that could impede movement. Use a vacuum cleaner that does not generate electrostatic discharge for fans inside the CPU compartment. Clean surfaces with diluted non-abrasive solutions like ammonia enzyme cleaners or alcohol solutions. Avoid strong solvents like trichloroethylene that damage the finish. Never use steel wool or abrasive materials. Always dispose of batteries according to local laws and recycle electronics properly. Keep the unit dry and wipe spills immediately.

Final Notes

  • Read all warnings before assembly to prevent injury.
  • Do not operate with missing parts or damaged components.
  • Contact support for authorized repairs only using specific tools.
  • Ensure all equipment is balanced during setup to avoid tipping.
  • Test movement regularly to ensure smooth operation and safety.
M: claude-opus-5-5

© Copyright 2026 Manual.ly