766918a95e12b9c7e9f41af6d9439ae48985 page 3
1
2
3
4
Envertech EVT800 Quick Installation
Guide
Please read and follow the safety and installation
instructions below. You can find and download
the instructions or other technical documents on
our website: www.envertec.com .
1. Accessories
A
M8 x 25 screws (Prepared by the installer)
B
5m AC extension cable
*Note: All accessories above are not included in
the package and should be purchased separately.
2. Create an Installation Map
a. Create a paper installation map to record
microinverter serial numbers and positions in
the array. Download the sheet with this QR
code.
b. Peel the removable serial number label from
each microinverter and affix it to the
respective location on the paper installation
map.
c. Always keep a copy of the installation map for
your records.
3. Installation Steps
Installation could only be implemented when the
system is disconnected from the grid, and the solar
panel has been covered or disconnected.
Step 1. Verify that grid voltage and PV panel
voltage are matching with microinverter
rating
Step 2. Mount microinverters onto the rack
Mark out the estimated center of each PV
module on the rack to facilitate locating
microinverters.
Mount all microinverters under modules to avoid
rain and sun, with the trademark facing
downward.
12
User Identificati on Number
-40℃ to +65℃
Temperature(℃) :
Operating Range (Vdc):
16V~60V
Normal Voltage?(Vac):
220/230V
MPPT Voltage R ange (Vdc):
22V~50V
Current (Max. C ontinuous) (A ):
3.63A
Max. DC Input ( Vdc):
60V
Frequency?(Hz):
50Hz/60Hz
Max. Input Cont inuous Curre nt?(A):
14Ax2
Power Factor Ra nge:
+/-0.90
Max. Input Shor t-Circuit Cu rrent (A):
25A Maximum Unit s Per Branch : 6
Power (Max. Co ntinuous) (W ):
800W
Overvoltage Cat egory: OVC III (AC Main), O VC II ( PV)
Ingress Protecti on (IP):
IP67 Protective Cl ass: Class I
Model: EVT 800
www.enverte c.com
Envertech(Sha nghai)Corp oration LTD .
PV Micro inverter
Step 3. Ground the system
Microinverters and modules must be connected
to the grounding conductor in accordance with
national standards. Fix the screws to the
microinverter installation hole. Make sure that
the grounding screw thread is pierced into the
bracket to get the best grounding effect.
Step 4. Install a WLAN antenna
For better WiFi signal, rotate the antenna
clockwise until it is firmly secured to the EVT800.
Step 5. Fasten AC cables
Fasten AC cables and grounding cables to the
rack with cable ties.
Step 6. Connect to the grid
Option a. Connect to air switch
1) Remove the skin of the two ends of the
extension cable by y=40mm and remove
the skin of internal wires by x=14mm. Set
the metal terminals onto the open parts
and clamp them to tighten the connection;
Y=40mmR
Y=14mmR
2) Connect the other side of the extension
cable to the air switch.
Extension cable
Option b. Put the open parts of the extension
cable into the plug and use the plug to
connect to the socket
Step 7. Connect PV modules to microinverters
Mount the PV modules on top of the
microinverters; Connect each PV module with
the DC input cables of the microinverter.
Step 8. Switch on the PV system
Ensure all connection is completed and then turn
on the air switch.
For the monitoring system (EnverBridge)
installation please scan this QR code .
4. Warranty Policy & Safety Info
Please register your product with the QR code
below to obtain full warranty benefits, or you
can only get a 2-year warranty.
12
User Identification Number
-40℃ to +65℃
Temperature(℃):
Operating Range (Vdc):
16V~60V
Normal Voltage?(Vac):
220/230V
MPPT Voltage Range (Vdc):
22V~50V
Current (Max. Continuous) (A):
3.63A
Max. DC Input (Vdc):
60V
Frequency?(Hz):
50Hz/60Hz
Max. Input Continuous Current?(A):
14Ax2
Power Factor Range:
+/-0.90
Max. Input Short-Circuit Current (A):
25A Maximum Units Per Branch: 6
Power (Max. Continuous) (W):
800W
Overvoltage Category: OVC III (AC Main), OVC II ( PV)
Ingress Protection (IP):
IP67 Protective Class: Class I
Model: EVT800
www.envertec.com
Envertech(Shanghai)Corporation LTD.
PV Microinverter

Chat with your Envertech EVT800-B manual using AI

Get instant AI answers from your Envertech EVT800-B manual

Ask anything about the Envertech EVT800-B. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend EVT800-B?

Yes No

Frequently Asked Questions

A

You must register your product using the provided QR code to obtain full warranty benefits. If registered, you receive extended coverage. Without registration, you are limited to a standard two-year warranty period only.

Is this answer helpful?

A

The device delivers a maximum continuous power of eight hundred watts. This ensures efficient energy conversion for compatible solar panel setups under normal operating conditions.

Is this answer helpful?

A

No. Attempting to repair the unit yourself voids the warranty and creates safety risks. It contains no user-serviceable parts. Contact customer service for returns if failure occurs.

Is this answer helpful?

A

WiFi functionality is built-in but the WLAN antenna must be installed manually. You need a phone or router with a 2.4GHz connection to configure the settings via the app.

Is this answer helpful?

A

The unit functions safely between negative forty degrees Celsius and positive sixty-five degrees Celsius. Extreme conditions may cause surface temperatures to reach ninety degrees Celsius.

Is this answer helpful?

A

No. M8 x 25 screws and the five meter AC extension cable are not included. You must purchase these separately to complete the installation process.

Is this answer helpful?

A

Connect the extension cable to either an air switch or a standard socket plug depending on your local infrastructure requirements. Follow all safety steps before switching on the system.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • High efficiency conversion with up to 800W continuous power output
  • Durable IP67 rating protects against dust and water ingress
  • Easy wireless setup using dedicated mobile application for monitoring
  • Wide operating temperature range suits various climate conditions
  • Independent control per module handles shading effectively
VS

Disadvantages

  • Essential AC extension cables sold separately from main package
  • Chassis becomes very hot during operation requiring caution
  • Strict warranty registration required to get full coverage period
  • Requires precise voltage matching between panels and unit
  • Unauthorized repairs will void all protection and service agreements
M: QW-35-FL

Product Specification

Note

Prices partially include 0% VAT rates for Austria and Germany

Type

Solar inverter, Microinverter, passive

Input Voltage

16-60V Direct Current (DC)

Input Current Max.

14A

MPPT Voltage Range

22-50V Direct Current (DC)

MPPT Count

2

Max PV Power

1.1 kWp

Output Power

800 W

Output Phases

1-phase

Efficiency

96.8% max.

Input Connector

MC4

Output Connector

BC01

Interfaces

Wi-Fi (WLAN)

Protection Rating

IP67

Operating Temperature

-40°F to +149°F

Dimensions

10.39x7.64x1.40in (WxHxD)

Weight

9.04 lbs

M: QW-35-FL

Product Description

Unlock Maximum Solar Potential with the Envertech EVT800-B

Harnessing the suns energy requires precision engineering and reliable components to maximize output efficiency. The Envertech EVT800-B stands out as a top-tier solution for residential and commercial photovoltaic systems seeking superior stability. This powerful microinverter ensures optimal performance even under partial shading conditions due to independent control per panel. Integrating the system into your property involves understanding the core operational flow and adhering to specific setup protocols to guarantee longevity and safety standards.

Why Choose This Unit

Efficiency is key when converting direct current from solar panels into usable alternating current for your home grid. The device supports an impressive eight hundred watt power output while maintaining a compact design suitable for various rooftop environments. Its ingress protection rating confirms durability against harsh weather elements including heavy rain and persistent dust accumulation over time. Users benefit from a wide operating temperature range ensuring stable function across diverse seasonal changes without overheating failures. The unit operates efficiently within a specified voltage range matching typical grid requirements for residential applications globally.

Setup Overview

Installing the equipment begins with verifying grid voltage compatibility before connecting any hardware components securely. Secure mounting underneath the module protects internal electronics from excessive heat and direct exposure to rain. Grounding procedures must follow national standards strictly to maintain safety integrity for the entire array effectively. Connectors require careful handling to prevent moisture ingress which could compromise the connection points over time significantly. Wireless configuration allows seamless integration with monitoring apps for real-time production data analysis on mobile platforms easily. A dedicated antenna improves signal strength for better network connectivity during setup phases.

Performance Notes

Monitoring tools enable users to track production metrics directly from their smartphones for complete transparency regarding energy usage. Registration is essential for securing full warranty coverage beyond the standard two-year period initially provided to customers. Thermal management is critical as chassis temperatures rise during operation potentially reaching high levels in extreme summer conditions. Always allow adequate airflow around the unit to mitigate overheating risks during peak sunlight hours effectively for safety. Contact support if you notice irregularities in performance data logs.

Critical Safety Information

Avoid attempting any repairs on the unit yourself as internal parts are not user-serviceable and tampering voids protection. Risks include electric shock and fire hazards if proper precautions are not followed during installation. Use labeled PV wires specifically designed for such connections to minimize fire risks associated with incorrect cabling types. Match the maximum open circuit voltage of your solar panels to prevent exceeding rated input limits dangerously. These measures protect both the installer and the investment for long-term viability.

To fully optimize your investment consult the extensive installation information available digitally without needing physical copies or downloads. Proper alignment with electrical specifications ensures safe operation throughout the expected lifecycle of the hardware components reliably. Remember that unauthorized modifications can invalidate safety certifications and insurance policies associated with your build project. Stay informed about regulatory updates affecting photovoltaic installations in your specific geographic region regularly for compliance. Access the Envertech EVT800-B Manual for detailed technical specifications and safety warnings relevant to your specific electrical environment needs.

M: QW-35-FL

© Copyright 2026 Manual.ly