Installation and Adjustment
Item number 70316
Leak KNX 2.0
Leakage sensor for water and pipe breakage reporting

Chat with your Elsner Leak KNX 2.0 manual using AI

Get instant AI answers from your Elsner Leak KNX 2.0 manual

Ask anything about the Elsner Leak KNX 2.0. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend Leak KNX 2.0?

Yes No

Frequently Asked Questions

A

It detects water when water bridges the electrodes on the floor probe. The device can then issue a local sound signal and send an alarm through the KNX bus.

Is this answer helpful?

A

Place the probe where water would likely collect first, such as near washing machines, sinks, bathtubs, pipes, pumps, or other water-carrying equipment. Position its electrodes downward on the floor.

Is this answer helpful?

A

Yes. The system can detect when the probe is disconnected or when its cable is faulty. This condition can be indicated acoustically and communicated to the KNX system as a sensor fault.

Is this answer helpful?

A

Yes. The audible alarm can be enabled or disabled in ETS, and a KNX communication object can be used for muting. If configured, the sound can resume after a defined mute time while an alarm remains active.

Is this answer helpful?

A

The evaluation unit requires 20 to 32 V DC auxiliary power and also connects to the KNX bus for data communication. Installation and commissioning should be performed by a qualified electrician.

Is this answer helpful?

A

The included probe cable is approximately 140 cm long, excluding strain relief and connector. It can be extended to a maximum length of 10 m to support more flexible positioning.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Detects water at the floor-level probe and sends alarm status to the KNX bus.
  • Provides audible alarms and configurable text notifications for water events.
  • Monitors for disconnected probes and cable faults, improving system supervision.
  • Includes 16 logic inputs plus four AND and four OR gates for advanced automation.
VS

Disadvantages

  • Requires KNX infrastructure, ETS 5 configuration, and professional electrical installation.
  • The evaluation unit is rated IP20 and must be mounted in a dry indoor location.
  • The probe is intended for water detection; electrode media resistance is specified for water only.
  • The 70316 evaluation unit is not compatible with the older 70314 probe.
M: gpt-5.6-terra

Product Specification

Type

Sensor

Standard

KNX

Function

Flood sensor, warning function

Topology

Bus

Dimensions

4.13 x 4.13 x 2.56 in

Special features

IP20, IP68

M: gpt-5.6-terra

Product Description

Elsner Leak KNX 2.0 Water Sensor, Flood Sensor - Read, Download & Print Free

The Elsner Leak KNX 2.0 Water Sensor, Flood Sensor is a smart building safety device designed to identify water leaks early and communicate them through a KNX installation. It combines a compact evaluation unit with a robust floor-mounted electrode probe, helping property owners react before a small leak becomes expensive water damage.

Early water detection for connected buildings

The probe detects water when it reaches the electrodes on its underside. This makes the sensor well suited to high-risk locations such as beneath washing machines, near sinks, bathtubs, water pipes, pumps, and utility equipment. Once water is detected, the system can activate an audible alarm and transmit an alarm status plus a customizable text message to the KNX bus.

The sensor does more than report moisture. It also supervises the probe connection and cable condition. A disconnected probe or damaged cable can trigger a separate fault indication, allowing the KNX system to flag a potential loss of protection. This additional monitoring is valuable where dependable water-leak coverage is essential.

Flexible KNX integration

Configuration is completed through ETS 5, giving installers detailed control over alarm behavior. Alarm on and off delays can be configured, including values received through communication objects. The audible signal can be enabled, muted remotely, and set to sound again after a defined mute period if the alarm remains active.

For automation projects, the Elsner Leak KNX 2.0 Water Sensor, Flood Sensor provides more than basic leak reporting. It includes 16 logic inputs, four AND gates, and four OR gates. Each logic gate supports up to four inputs and can be configured with 1-bit or two 8-bit outputs. These options can support actions such as closing a water valve, notifying occupants, switching equipment, or combining leak status with other building conditions.

Practical installation design

The evaluation unit is intended for dry indoor mounting and should be installed outside the area likely to be flooded. The stainless-steel probe is rated IP68 and is made to rest on the floor with its electrodes facing downward. It can be secured to prevent movement, while the approximately 140 cm probe cable may be extended up to 10 m for more flexible placement.

The evaluation unit uses 20 to 32 V DC auxiliary power and connects to the KNX bus. Its compact surface-mounted enclosure measures approximately 105 x 105 x 65 mm. Professional electrical installation is required to ensure correct wiring, safe operation, and reliable integration with the wider automation system.

Note: Position the probe at the lowest or earliest-flooded point in the protected area. Keep the evaluation unit dry, and verify that the supplied probe is compatible with the 70316 Leak KNX 2.0 unit.