Elsner KNX VOC/TH-UP Touch Manual
PDF manual · 68 Pages
English

Quick check
Incorrect answer, please try again.
Chat with your Elsner KNX VOC/TH-UP Touch manual using AI
Get instant AI answers from your Elsner KNX VOC/TH-UP Touch manual
Ask anything about the Elsner KNX VOC/TH-UP Touch. Answers come from this manual, with the pages they are based on.
Ask a Question
Do you recommend KNX VOC/TH-UP Touch?
Yes NoFrequently Asked Questions
It measures VOC mixed gases as a CO2-equivalent air-quality value, room temperature, and relative humidity. It also calculates dew point and can output absolute humidity values through KNX communication objects.
Is this answer helpful?
Yes. Integrated PI controllers support one- or two-stage heating and cooling. Setpoints and operating modes can be configured for Comfort, Standby, Eco, and building-protection operation.
Is this answer helpful?
The sensor can use VOC concentration for one- or two-stage ventilation control. It also supports humidity-based dehumidification or combined humidification and dehumidification control through KNX outputs.
Is this answer helpful?
They can adjust the room-temperature setpoint, change operating modes, or be configured as general KNX push buttons. Available functions include switching, dimming, value transmission, and scene control.
Is this answer helpful?
A wind-tight flush-mounted box helps prevent drafts through the wall cavity from distorting the mixed-gas reading. Conduits leading into the box should also be sealed to avoid airflow.
Is this answer helpful?
Yes. External temperature, humidity, and VOC values can be received through KNX. They can be combined with local values using a configurable percentage to create a total or averaged measurement.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Combines VOC, temperature, relative humidity, absolute humidity, and dew-point monitoring in one KNX wall unit.
- Supports integrated PI control for heating, cooling, ventilation, humidification, and dehumidification.
- Two touch buttons and a configurable display provide local feedback and room-temperature control.
- Offers flexible automation with threshold outputs, external-value mixing, AND/OR logic, and control-value comparators.
- Fits common 55 x 55 mm switch-system frames and is available in white or black.
Disadvantages
- Requires ETS 5 or later and KNX commissioning knowledge for full configuration.
- Frame and DIN 49073 flush-mounted box are required separately.
- VOC accuracy depends on careful installation in a wind-tight box with sealed conduits.
- Designed only for dry indoor areas and must be protected from condensation, water, and dust.
- Measurement readings can be influenced by sunlight, drafts, and nearby heating or cooling sources.
Product Specification
Type
Hardware control unit
Standard
KNX
Function
Control, temperature, humidity, air quality, ventilation control, heating control
Topology
Bus/star
Dimensions
2.17 x 2.17 x 0.31 in
Product Description
Elsner KNX VOC/TH-UP Touch Manual: Smarter Indoor Climate Control
The Elsner KNX VOC/TH-UP Touch is a compact indoor combination sensor designed for KNX building automation. It brings air-quality monitoring, temperature and humidity measurement, visual feedback, and local control together in a wall-mounted unit. Available in white or black, the sensor fits a 55 x 55 mm switch-system frame, helping it blend into modern residential and commercial interiors.
Monitor the conditions that shape comfort
The sensor measures volatile organic compounds (VOCs) and expresses the mixed-gas result as a CO2-equivalent air-quality value. Its VOC measuring range is 400 to 2000 ppm with 1 ppm resolution. It also measures temperature from 0 to 50 degrees C and relative humidity from 0 to 95 percent RH. Using the temperature and humidity data, it calculates dew point and can provide absolute humidity values.
This combination supports a more informed response to changing indoor conditions. Configurable limits are available for temperature, humidity, and VOC concentration, allowing KNX actions to be triggered when values rise above or fall below defined thresholds. The device can also combine its own values with external KNX measurements, making it useful where a weighted room-average value is required.
Integrated controls and display
A built-in display can show one to three lines of measured or received KNX values, including date and time. It can also present a temperature-control screen with operating mode and setpoint information. Two touch buttons may be assigned for setpoint adjustment, switching between Comfort, Standby, Eco, and building-protection modes, or freely configured as KNX push buttons for functions such as switching, dimming, value transmission, and scenes.
The Elsner KNX VOC/TH-UP Touch Manual highlights integrated PI control for heating and cooling, with one- or two-stage operation. Separate configurations support ventilation control based on VOC level, humidity-based dehumidification, and combined humidification/dehumidification. A dew-point-related cooling-medium monitor can help signal conditions that could lead to condensation.
Flexible KNX logic for tailored automation
Beyond sensing and control, the unit includes four AND gates, four OR gates, and two control-value comparators. These functions can link switching events and communication objects directly within the KNX installation. This reduces the need for separate logic in straightforward automation scenarios.
Notes
- Installation is intended for dry indoor locations by an authorized electrical professional.
- A wind-tight flush-mounted box and sealed conduits are important for reliable mixed-gas measurement.
- Direct sun, drafts, and nearby hot or cold building components can affect measurement results.
- Configuration requires ETS 5 or later and KNX bus power.