The Elro FS1105P operates on 230 volts AC at 50 Hz. It also includes a 9V backup battery.
Is this answer helpful?
You can connect a maximum of 12 devices together. This ensures if one triggers, all alarm simultaneously.
Is this answer helpful?
The device uses a 9V battery, with specific recommended types like Gold Peak GP1604S or Raymax 6LR61.
Is this answer helpful?
Mount on the ceiling at least 50cm from walls. Avoid air conditioning vents and keep away from steam.
Is this answer helpful?
Green constant means AC power. Red flashing every 32 seconds is normal operation or low battery.
Is this answer helpful?
Yes, there is a silence facility. However, if there is an alarm, only silence if you are sure it is safe.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Interconnectable up to 12 devices for whole home coverage
- Includes 9V backup battery for power outages
- 85dB alarm volume effective at 3 meters
Disadvantages
- Requires mains power cut for safe installation
- Battery life shortens without monthly testing
- Strict distance rules apply near vents or walls
Product Specification
Type
Smoke Detector
Sensors
Smoke
Alarm Zones
1
Standard
N/A
Coverage Area
344.45 sq ft
Power Supply
Mains (230V), Battery (1x 9V Block)
Operating Temperature
32°F to 104°F
Dimensions
Ø4.92x1.57 in
Weight
4.80 oz
Features
Siren (85 dBA)
Product Description
Secure Your Home with the Elro FS1105P Smoke Detector
Ensuring the safety of your living space requires reliable protection against unexpected fire hazards. The Elro FS1105P Smoke Detector stands as a robust solution designed for residential environments. It operates primarily on 230 volts AC power, ensuring continuous monitoring while relying on an included 9V backup battery during outages. This dual-power system guarantees that your home remains protected even when the mains supply fails.
Installation and Connectivity Options
Mounting the device is straightforward when following the standard guidelines. The unit is designed for ceiling installation to maximize smoke detection efficiency. One standout feature is the ability to interconnect up to twelve units. This network capability ensures that if one alarm detects smoke, all linked alarms trigger simultaneously, providing comprehensive coverage throughout the property.
When reviewing the technical guidance found in the Elro FS1105P Smoke Detector Manual, users discover specific positioning requirements. Placing the device too close to corners or ventilation sources can impact performance. Maintaining a minimum distance of 50 cm from walls reduces airflow interference. Proper spacing ensures rapid detection of smoke particles within the room. The operating temperature range allows use in various climates between 0 and 40 degrees Celsius.
Performance and Maintenance
The alarm emits a loud 85dB signal at three meters, which is distinct enough to wake sleepers in adjacent rooms. A visual LED indicator provides status updates at a glance. A constant green light indicates power is active, while flashing red lights alert users to alarms, low batteries, or faults. Regular testing is crucial for maintaining operational reliability.
The LED signal frequency changes based on the mode. Normal mode flashes once every 32 seconds. During an alarm, it flashes and beeps constantly. The alarm silence facility mutes the sound but keeps the light active. Low battery warnings use a different rhythm to distinguish from system faults. Understanding these signals helps users diagnose issues quickly without professional assistance.
Fire safety is not just about compliance; it is about protecting loved ones. This device meets European standards for fire safety characteristics including tolerance to supply voltage and humidity resistance. The optical sensor effectively identifies particulate matter without producing false positives easily. However, placement near steam or dust can cause nuisance alarms.
To prevent false triggers, avoid installing the alarm directly under air conditioning vents. If a false alarm occurs, silence the device using the mute function, but verify the situation is safe first. If doubt persists, evacuate the building immediately. The 9V battery is included, ensuring the unit is ready upon activation.
The product is suitable for various leisure accommodation vehicles as well, making it versatile for holiday homes. When installing, always turn off the mains power to avoid electrical shocks. Wire connections should follow national electrical regulations using 1.5mm2 cable. This ensures durability and long-term safety.
Remember to clean the detector annually. Dust accumulation inside the sensor chamber can reduce sensitivity. Use a soft cloth or vacuum attachment gently. If the unit fails the annual test, it should be replaced entirely. Battery replacement should only be done with the recommended models to maintain safety certifications. Proper disposal according to the WEEE symbol is required for environmental protection.
Maintenance Notes
Do not paint the device or cover it with materials. Keep away from excessive heat sources like fire. Replace batteries with specified types to avoid explosion risks. Monthly testing extends battery life and ensures reliability.