e66a4b634ebc516b73f1b4a717acf7d27e5e page 10
GB
- 16 -
Danger!
When using the equipment, a few safety pre-
cautions must be observed to avoid injuries and
damage. Please read the complete operating
instructions and safety regulations with due care.
Keep this manual in a safe place, so that the in-
formation is available at all times. If you give the
equipment to any other person, hand over these
operating instructions and safety regulations as
well. We cannot accept any liability for damage
or accidents which arise due to a failure to follow
these instructions and the safety instructions.
Explanation of the warning signs on the
machine (Fig. 8)
1. Danger! Read the operating instructions.
2. Warning! Hot parts. Keep your distance.
3. Danger! Switch off the engine before refue-
ling.
4. Danger! The exhaust gases from the genera-
tor are toxic. Risk of suff ocation.
5. Danger! Never operate in non-ventilated
rooms.
6. Beware of infl ammable materials.
7. Beware of electrical voltage.
1. Safety regulations
Danger!
Read all safety regulations and instructions.
Any errors made in following the safety regula-
tions and instructions may result in an electric
shock, fi re and/or serious injury.
Keep all safety regulations and instructions
in a safe place for future use.
•
No changes may be made to the generator.
•
Only original parts may be used for mainte-
nance and accessories.
•
Important: Danger of poisoning, do not inhale
•
emissions.
•
Children are to be kept away from the gene-
rator.
•
Important: Risk of burns. Do not touch the
exhaust system or drive unit.
•
Wear suitable ear protection when in the vici-
nity of the equipment.
•
Important: Petrol and petrol fumes are highly
combustible or explosive.
•
Never operate the generator in non-ventilated
rooms or in easyly inflammable adjacency.
When operating the generator in rooms with
good ventilation, the exhaust gases must
be channeled directly outdoors through an
exhaust hose. Important: Toxic exhaust gases
can escape despite the exhaust hose. Due to
the fire hazard, never direct the exhaust hose
towards inflammable materials.
•
Risk of explosion: Never operate the genera-
tor in rooms with combustible materials.
•
The speed preset by the manufacturer is not
allowed to be changed. The generator or
connected equipment may be damaged.
•
Secure the generator against shifting and
toppling during transport.
•
Place the generator at least 1m away from
buildings and the equipment connected to it.
•
Place the generator in a secure, level positi-
on. Do not turn, tip or change the generator‘s
position while it is working.
•
Always switch off the engine when trans-
porting and refueling the generator.
•
Make sure that when you refuel the generator
no fuel is spilt on the engine or exhaust pipe.
•
Never operate the generator in rain or snow.
•
Never touch the generator with wet hands.
•
Guard against electric danger. When working
outdoors, use only extension cables that are
approved for outdoor use and which are
marked accordingly (H07RN..).
•
If you use extension cables or mobile distribu-
tion networks, the resistance value must not
exceed 1.5 Ω. As a reference value, cables
with a cross-section of 1.5 mm² should not
be any longer than 60 m in length, and cables
with a cross-section of 2.5 mm² should not be
any longer than 100 m.
•
No changes may be made to the settings of
the motor or generator.
•
Repairs and adjustment work may only be
carried out by authorized trained personnel.
•
Do not refuel or empty the tank near open
lights, fire or sparks. Do not smoke!
•
Do not touch any mechanically driven or hot
parts. Do not remove the safety guards.
•
Do not expose the tools to damp or dust.
Permissible ambient temperature – 10 to +
40 °C, max. altitude above sea level 1000 m,
relative humidity: 90 % (non-condensing)
•
The generator is driven by a combustion en-
gine, which produces heat in the area of the
exhaust (on the opposite side of the sockets)
and the exhaust outlet. You should therefore
keep clear of these surfaces because of risk
of skin burns.
•
Fuel is combustible and highly flammable. Do
not fill up while in operation.
•
Some parts of the reciprocating internal com-
Anl_TC_IG_2000_SPK9.indb 16Anl_TC_IG_2000_SPK9.indb 16 20.08.2020 14:19:2420.08.2020 14:19:24

Chat with your Einhell TC-IG 2000 manual using AI

Get instant AI answers from your Einhell TC-IG 2000 manual

Ask anything about the Einhell TC-IG 2000. Answers come from this manual, with the pages they are based on.

TC-IG 2000 Maintenance Schedule

After every use
Clean the generator housing and vents

Wipe with a clean cloth or blow out dust with low-pressure air. Do not use solvents. Ensure no water enters the device.

Regularly
Clean the air filter

Tap elements on a flat surface to remove dirt. If heavily soiled, wash with soapy water, rinse, and air dry. Replace if necessary.

Every 50 operating hours
Service the spark plug

Check for dirt after first 10 hours. Thereafter, clean with a copper wire brush every 50 operating hours. Check electrode gap (0.6 mm).

Before each use
Check engine oil level

Insert dipstick into thread without screwing it in. Top up oil to the upper mark if low. Use approx. 0.6 l of engine oil.

Periodically
Change engine oil

Perform when motor is warm. Drain old oil via drain plug on inclined surface, close plug, and refill to top mark. Dispose of waste oil properly.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend TC-IG 2000?

Yes No

Frequently Asked Questions

A

The generator supplies 1,800 W of continuous rated power at 230 V. It can provide up to 2,000 W for a maximum of five minutes, followed by a cooling period.

Is this answer helpful?

A

It is designed for compatible 230 V AC tools and lighting, plus 5 V USB-powered devices. Check each appliance's voltage, running load, and start-up demand before use.

Is this answer helpful?

A

No. Do not connect the generator directly to a household mains system or wall socket. A special backup connection requires a qualified electrician.

Is this answer helpful?

A

The unit uses normal unleaded E10 petrol. Its tank holds 4 litres, and consumption is approximately 0.75 litres per hour at two-thirds load.

Is this answer helpful?

A

The overload cut-out switches off the affected sockets. Reduce the connected electrical load or remove faulty equipment before resuming operation.

Is this answer helpful?

A

The automatic low-oil cut-out prevents starting or stops the engine when oil is insufficient. Check and refill engine oil to the correct level before restarting.

Is this answer helpful?

A

Operate it outdoors on a secure, level surface with good ventilation. Keep it away from buildings, flammable materials, rain, snow, and enclosed spaces because exhaust gases are toxic.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Inverter generator provides 1,800 W continuous output and up to 2,000 W maximum output for short periods.
  • Two 230 V AC outlets and two 5 V USB ports support tools, lighting, and compatible device charging.
  • Low-oil cut-out and overload protection help protect the engine and connected outlets.
  • 4-litre E10 petrol tank and approximately 0.75 l/h consumption at two-thirds load support portable use.
  • Integrated transport handle and 21.5 kg weight support easier positioning and carrying.
VS

Disadvantages

  • Maximum 2,000 W output is limited to five minutes, so high-demand loads need careful planning.
  • Manual recoil starting requires physical effort and protective gloves are recommended.
  • Petrol engine exhaust requires outdoor or properly ventilated use only.
  • At up to 95 dB(A) sound power, hearing protection is recommended nearby.
  • Not designed for commercial, trade, or industrial applications.
M: gpt-5.6-terra

Product Specification

Type

Gasoline generator

Engine Power

2.4 kW, 3.25 hp, 105.6 cc, 4-stroke

Rated Power

1.8 kW (230 V)

Output

2x outlets (230 V), 2x USB charging ports

Fuel Tank Capacity

1.06 gal

Features

Inverter technology, carrying handle, overload protection, low-oil shutdown

Noise Level

95 dB(A)

Dimensions

23.62 x 20.28 x 14.84 in (W x H x D)

Weight

47.4 lb

M: gpt-5.6-terra

Product Description

Einhell TC-IG 2000 Gasoline Generator - Read, Download & Print Free

The Einhell TC-IG 2000 Gasoline Generator is a compact inverter generator designed to supply dependable electricity where a standard mains connection is unavailable. Suitable for camping, outdoor work, lighting, and selected household appliances during planned off-grid use, it delivers 230 V AC power through two sockets and adds two 5 V USB outputs for charging compatible mobile devices.

Power for practical everyday needs

Its inverter generator design provides a continuous rated output of 1,800 W and a maximum output of 2,000 W for up to five minutes. This capacity makes it a practical choice for lamps, chargers, small power tools, and other compatible 230 V appliances. Before connecting equipment, check its voltage and starting-power requirements, as motors in tools such as drills and jigsaws can draw more power when starting or operating under load.

The generator uses a 105.6 cc, air-cooled four-stroke petrol engine with a maximum engine output of 2.4 kW or 3.3 hp. A 4-litre E10 petrol tank and consumption of around 0.75 litres per hour at two-thirds load support portable power sessions without frequent refueling. At 21.5 kg, the unit remains manageable for transport with its integrated carrying handle.

Connections and protective features

The front panel combines two 230 V outlets, two USB ports, LED status indicators, an earthing connection, and controls for starting and operation. An overload cut-out protects the sockets by disconnecting them if demand exceeds the supported load. Reduce the connected load and inspect connected appliances if this happens.

An automatic low-oil cut-out adds another important safeguard. If engine oil is too low, the engine will not start or will switch off shortly after starting. Check the oil level before every use and fill the engine with the required oil before its first start. The generator also includes a recoil starter, choke lever, fuel cock, spark plug wrench, and oil filling funnel.

Safe operation matters

Use the Einhell TC-IG 2000 only outdoors or in suitably ventilated conditions, well away from doors, windows, combustible materials, and people. Exhaust gases are toxic, while the engine and exhaust become hot during operation. Keep the unit on a stable, level surface at least one metre from buildings and connected equipment. Never operate it in rain or snow, touch it with wet hands, or connect it directly to a household mains system.

Notes

  • Use only appliances matching the generator's voltage and output limits.
  • Let the generator run briefly without load before switching it off.
  • Clean the air filter regularly and inspect the spark plug after the first 10 operating hours.