Danger!
When using the equipment, a few safety pre-
cautions must be observed to avoid injuries and
damage. Please read the complete operating
instructions and safety regulations with due care.
Keep this manual in a safe place, so that the in-
formation is available at all times. If you give the
equipment to any other person, hand over these
operating instructions and safety regulations as
well. We cannot accept any liability for damage
or accidents which arise due to a failure to follow
these instructions and the safety instructions.
1. Safety regulations
Caution!
The pump must be powered via an earth-
leakage circuit breaker (RCD) with a rated
fault current of no more than 30 mA (accor-
ding to VDE 0100 Part 702 and 738).
The equipment is not designed for use in
swimming pools and paddling pools of any
kind or other bodies of water in which people
or animals may be present during operation.
It is prohibited to operate the equipment if a
person or animal is in the danger area. Ask
your electrician!
This equipment can be used by
children of 8 years and older and
by people with limited physical,
sensory or mental capacities or
those with no experience and
knowledge if they are supervised
or have received instruction in
how to use the equipment safe-
ly and understand the dangers
which result from such use.
Children are not allowed to play
with the equipment. Unless su-
pervised, children are not allo-
wed to clean the equipment and
carry out user-level maintenance
work.
Danger!
•
Before you put the equipment into operation,
arrange for a specialist to check that the
- earthing
- protective multiple earthing
- residual-current operated circuit-breaker
circuit
comply with the safety regulations of the pow-
er supply company and work correctly.
•
The electrical plug-in connections must be
protected from wet conditions.
•
If there is a risk of flooding, place the plug-in
connections in an area which is safe from
flooding.
•
Strictly avoid pumping aggressive liquids and
abrasive substances.
•
Protect the equipment from frost.
•
Protect the equipment from dry running.
•
Take suitable measures to keep the equip-
ment out of the reach of children.
Danger!
Read all safety regulations and instructions.
Any errors made in following the safety regula-
tions and instructions may result in an electric
shock, fi re and/or serious injury.
Keep all safety regulations and instructions
in a safe place for future use.
2. Layout and items supplied
2.1 Layout (Fig. 1/2)
1. Carry handle
2. Mains cable
3. Float switch
4. Intake cage
5. Float switch mounting
6. Aluminium tube, long
7. Aluminium tube, short
8. Aluminium tube with attachment hook
9. Swiveling connection with stopcock
2.2 Items supplied
Please check that the article is complete as
specifi ed in the scope of delivery. If parts are
missing, please contact our service center or the
sales outlet where you made your purchase at
the latest within 5 working days after purchasing
the product and upon presentation of a valid bill
of purchase. Also, refer to the warranty table in
the service information at the end of the operating
instructions.
•
Open the packaging and take out the equip-
Anl_GE-SP 3546 RB_SPK1.indb 15Anl_GE-SP 3546 RB_SPK1.indb 15 01.09.2017 13:03:5701.09.2017 13:03:57

Chat with your Einhell GE-SP 3546 RB manual using AI

Get instant AI answers from your Einhell GE-SP 3546 RB manual

Ask anything about the Einhell GE-SP 3546 RB. Answers come from this manual, with the pages they are based on.

GE-SP 3546 RB Maintenance Schedule

Remind me when maintenance is due
Every 3 months
Check float switch function

For stationary installation, verify the float switch operates correctly every three months.

Every 3 months
Clean shaft bottom and walls

Remove sludge from the shaft bottom and clean the shaft walls every three months.

After every use
Clean pump with clear water

For mobile applications, clean the device with clear water after every usage to prevent dirt buildup.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend GE-SP 3546 RB?

Yes No

Frequently Asked Questions

A

It is designed to pump rainwater and other clean water from barrels, shafts, and similar areas. It is useful for watering gardens, moving water around the home, and basic drainage tasks.

Is this answer helpful?

A

Yes. It uses a float switch that can turn the pump on and off based on water level. The switching point can also be adjusted to suit different setups.

Is this answer helpful?

A

No, it is not intended for permanent continuous use. It can be used manually for longer operation, but only under supervision to avoid dry running and damage.

Is this answer helpful?

A

It is meant for water up to 35 °C. It should not be used with fuel, cleaning chemicals, aggressive liquids, or abrasive substances.

Is this answer helpful?

A

The pump has a 350-watt motor and can move up to 4,600 liters per hour with a 1-inch hose setup. The flow is lower with a rain barrel pipe connection.

Is this answer helpful?

A

Yes. The intake, filter, and float switch should be cleaned regularly, especially if the water contains dirt or sludge. This helps keep performance stable and extends service life.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • 350 W motor delivers solid pumping power for rainwater use.
  • Float switch helps automate operation and reduce manual monitoring.
  • Adjustable switching levels make setup more flexible.
  • Built-in filter adds protection against larger dirt particles.
VS

Disadvantages

  • Not suitable for continuous operation such as permanent pond circulation.
  • Must not be used with aggressive or abrasive liquids.
  • Performance can drop quickly if the intake becomes clogged.
  • Maximum water temperature is limited to 35 °C.
M: OA-GPT-54-NAN

Product Specification

Power

350W

Flow rate

1214.99 gal/h

Delivery head

36.09 ft

Immersion depth

22.97 ft

Hose connection

1.04 in

Special features

without tank

Cable length

32.81 ft

Weight

9.75 lb

M: OA-GPT-54-NAN

Product Description

Einhell GE-SP 3546 RB Electric Rain Barrel Pump

The Einhell GE-SP 3546 RB Electric Rain Barrel Pump is a practical solution for anyone who wants to reuse rainwater efficiently in the garden or around the home. Compact, reliable, and designed for everyday watering tasks, it helps turn a simple rain barrel into a useful water source for plants, cleaning, and light transfer jobs. The included Einhell GE-SP 3546 RB Electric Rain Barrel Pump Manual highlights how important correct setup and safe operation are, but the product itself is built to make that process straightforward.

With a 350-watt motor and a maximum flow rate of up to 4,600 l/h when used with the right hose setup, this pump is made for efficient water movement without unnecessary complexity. It also offers a maximum delivery head of 11 meters, which gives it enough strength for many typical household and garden applications. A float switch adds convenience by helping control water levels automatically, while the adjustable switching point makes it easier to match the pump to different barrel or shaft conditions.

One of the most appealing features is its versatility. The pump can be used for rain barrels, small drainage tasks, and general water transfer, as long as the water stays within the recommended limits. It supports water temperatures up to 35 °C and includes a filter to help protect internal components from dirt and debris. The manual mode is also useful when continuous pumping is needed under supervision, though this should be handled carefully to avoid dry running.

The design also focuses on practical installation. A hanging hook and aluminum tube sections make setup easier, and the swiveling connection with stopcock supports controlled water withdrawal. For users who want a dependable rain barrel pump that balances power, simplicity, and everyday usability, this Einhell model is a strong fit.

Notes

  • Best suited for clean or lightly contaminated rainwater.
  • Not intended for pools, aggressive liquids, or continuous pond use.
  • Regular cleaning improves performance and service life.
  • Always keep electrical connections dry and protected.