Danger! - Read the operating instructions to reduce the risk of inquiry
This equipment can be used by children of 8 years and older and by
people with limited physical, sensory or mental capacities or those
with no experience and knowledge if they are supervised or have re-
ceived instruction in how to use the equipment safely and understand
the dangers which result from such use. Children are not allowed to
play with the equipment. Unless supervised, children are not allowed
to clean the equipment and carry out user-level maintenance work.
Anl_GE-PP_1100_N_A_SPK9.indb 15Anl_GE-PP_1100_N_A_SPK9.indb 15 30.08.2017 09:36:2730.08.2017 09:36:27

Chat with your Einhell GE-PP 1100 N-A manual using AI

Get instant AI answers from your Einhell GE-PP 1100 N-A manual

Ask anything about the Einhell GE-PP 1100 N-A. Answers come from this manual, with the pages they are based on.

GE-PP 1100 N-A Maintenance Schedule

Remind me when maintenance is due
Every 3 months
Check pump operation

For stationary use, check every three months that the pump is working properly.

Show in the manual (page 18)
Every 3 months
Clean the shaft bottom and walls

Remove sludge from the shaft bottom and clean the shaft walls every three months.

Show in the manual (page 18)
After every use
Clean the pump with clear water

For mobile use, clean the equipment with clear water after every use. Unplug the power plug before maintenance work.

Show in the manual (page 18)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: gpt-5.6-terra

Ask a Question

0/1000

Do you recommend GE-PP 1100 N-A?

Yes No

Video Manual

How To Use Einhell Clean and Dirty Water Pump | Toolstation

Frequently Asked Questions

A

The pump delivers up to 6,000 litres per hour with a maximum delivery head of 45 metres, powered by an 1100 W motor.

Is this answer helpful?

A

No. The pump is not designed for continuous operation; using it as a permanent circulation pump will significantly shorten its expected service life.

Is this answer helpful?

A

It has an automatic dry-run protection that stops pumping when no water is detected and performs periodic retry cycles (30 s on / 5 s off sequences repeated at intervals) until immersion of at least 12 cm restores normal operation.

Is this answer helpful?

A

The pump must be powered via an RCD (residual-current device) with a rated fault current of no more than 30 mA, connected to a properly earthed 220–240 V ~ 50 Hz supply with adequate fuse (min. 6 A). Keep plug connections dry and, if flood risk exists, position them above flood level.

Is this answer helpful?

A

Unplug before maintenance. Rinse with clear water after portable use; for stationary installations check function every three months, clean intake sieve and remove sludge from the shaft as needed. For heavy deposits, remove the 8 lower screws to access and clean the impeller. No further internal serviceable parts are required.

Is this answer helpful?

A

No. It is intended for clear water only; abrasive or heavily contaminated water can reduce performance and cause wear, requiring cleaning or parts replacement.

Is this answer helpful?

A

Check mains power and socket, inspect and clean the intake sieve, remove any kinks in the discharge hose, and clean shaft and pump housing. If the motor protection has tripped due to contamination or high temperature, unplug and clean the unit and ensure water temperature does not exceed 35°C.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High flow rate up to 6000 l/h with a strong 1100 W motor for efficient water transfer.
  • Automatic pressure control with integrated non-return valve and auto-restart below 2.5 bar.
  • Dry-run protection with intelligent retry cycles to prevent motor damage.
  • Submersible to 12 m with IPX8 protection for reliable underwater use.
  • Simple maintenance: removable lower housing and washable intake sieve.
VS

Disadvantages

  • Not designed for continuous operation (e.g., permanent pond circulation) — reduces lifespan if used continuously.
  • Suitable only for clear water; cannot handle abrasive, aggressive or chemical liquids.
  • Requires RCD (≤30 mA) and proper earthing; installation needs correct electrical protection.
  • Not intended for use in swimming pools or where people/animals are present during operation.
  • Mains cable replacement must be done by manufacturer or qualified service, adding potential service cost.
M: OA-GPT-5-NAN

Product Specification

Power

1,100 W

Flow rate

1,584.70 gal/h

Delivery height

147.64 ft

Immersion depth

39.37 ft

Pressure

65.27 psi

Hose connection

1"

Special features

without tank

Cable length

49.21 ft

Weight

19.18 lb

M: OA-GPT-54-NAN

Product Description

Einhell GE-PP 1100 N-A Electric Submersible Pressure Pump

The Einhell GE-PP 1100 N-A is a versatile electric submersible pressure pump built for domestic and garden water transfer tasks. With a powerful 1,100 W motor it delivers up to 6,000 l/h and a maximum delivery head of 45 m, making it suitable for drainage, irrigation and boosting household water supplies where clear water is required. Designed for intermittent rather than continuous operation, this pump is best for wells, shafts, garden ponds (not for continuous pond circulation) and other situations where temporary or periodic pumping is needed.

Key features and operation

The pump accepts a 1" (33.3 mm) threaded hose connection and can be submerged to a maximum depth of 12 m. It handles water temperatures up to 35°C and has IPX8 protection for submersible use. For safety it must be operated from a supply with an RCD (residual-current device) ≤30 mA and an adequately fused socket (min. 6 A). The GE-PP 1100 N-A includes an integrated non-return valve to keep pressure in the delivery line and an automatic mode: it builds pressure, switches off when a tap is closed and restarts when pressure falls below about 2.5 bar.

The pump features dry-run protection that stops operation when water is absent and performs periodic re-check cycles (30 s on / 5 s off sequences repeated at increasing intervals) until water is available again. Installation can be stationary with rigid piping or a flexible hose; the unit must be secured by its handle with a rope or cable when lowered into a well or shaft. For muddy or silty bottoms place the pump slightly elevated (e.g., on bricks) to reduce intake clogging.

Maintenance and care

Routine upkeep is simple: unplug before any service, rinse with clear water after portable use, and inspect function every three months for stationary installations. Clean the intake sieve and remove sludge from the pump shaft as needed. If heavy deposits accumulate, the lower housing can be opened (8 screws) and the impeller cleaned. There are no user-serviceable parts beyond cleaning; any damaged mains cable must be replaced by the manufacturer or qualified service personnel. Spare parts and service contacts are available via iSC/Einhell service portals.

Safety and proper use

Only pump clear water—no aggressive, abrasive or chemical fluids—and protect the pump from frost and dry running. Do not use for swimming pools or where people or animals could be in the danger zone while the pump runs. The product is intended for domestic consumer use; commercial or industrial use voids warranty and is not recommended.

Notes

  • Maximum performance requires adequate hose/pipe diameter; smaller hoses reduce flow.
  • Keep electrical connections dry and above potential flood levels.
  • Store in a dry, frost-free place between 5–30°C when not in use.