Danger!
When using the equipment, a few safety pre-
cautions must be observed to avoid injuries and
damage. Please read the complete operating
instructions and safety regulations with due care.
Keep this manual in a safe place, so that the in-
formation is available at all times. If you give the
equipment to any other person, hand over these
operating instructions and safety regulations as
well. We cannot accept any liability for damage
or accidents which arise due to a failure to follow
these instructions and the safety instructions.
Explanation of the symbols used (see Fig. 4)
1. Danger! - Read the operating instructions to
reduce the risk of injury.
1. Safety regulations
Danger!
Read all safety regulations and instructions.
Any errors made in following the safety regula-
tions and instructions may result in an electric
shock, fi re and/or serious injury.
Keep all safety regulations and instructions
in a safe place for future use.
This equipment can be used by children of 8 ye-
ars and older and by people with limited physical,
sensory or mental capacities or those with no ex-
perience and knowledge if they are supervised or
have received instruction in how to use the equip-
ment safely and understand the dangers which
result from such use. Children are not allowed
to play with the equipment. Unless supervised,
children are not allowed to clean the equipment
and carry out user-level maintenance work.
Danger!
The pump must be powered via an earth-
leakage circuit breaker (RCD) with a rated
fault current of no more than 30 mA (accor-
ding to VDE 0100 Part 702 and 738).
The equipment is not designed for use in
swimming pools and paddling pools of any
kind or other bodies of water in which people
or animals may be present during operation.
It is prohibited to operate the equipment if a
person or animal is in the danger area. Ask
your electrician!
Danger!
•
Before you put the equipment into opera-
tion, arrange for a specialist to check that
the earthing, protective multiple earthing or
residual-current operated circuit-breaker cir-
cuit comply with the safety regulations of the
power supply company and work correctly.
•
The electrical plug-in connections must be
protected from wet conditions.
•
If there is a risk of flooding, place the plug-in
connections in an area which is safe from
flooding.
•
Strictly avoid pumping aggressive liquids and
abrasive substances.
•
Protect the equipment from frost.
•
Protect the equipment from dry running.
•
Take suitable measures to keep the equip-
ment out of the reach of children.
2. Layout and items supplied
2.1 Layout (Fig. 1)
1. Handle
2. Floating switch
3. Universal hose connection
4. Hose connection 50 mm (2”)
5. Lock for fl oat switch
2.2 Items supplied
Please check that the article is complete as
specifi ed in the scope of delivery. If parts are
missing, please contact our service center or the
sales outlet where you made your purchase at
the latest within 5 working days after purchasing
the product and upon presentation of a valid bill
of purchase. Also, refer to the warranty table in
the service information at the end of the operating
instructions.
•
Open the packaging and take out the equip-
ment with care.
•
Remove the packaging material and any
packaging and/or transportation braces (if
available).
•
Check to see if all items are supplied.
•
Inspect the equipment and accessories for
transport damage.
•
If possible, please keep the packaging until
the end of the guarantee period.
Anl_GE_DP_900_Cut_SPK13.indb 14Anl_GE_DP_900_Cut_SPK13.indb 14 02.11.2021 14:20:5402.11.2021 14:20:54

Chat with your Einhell GE-DP 900 Cut manual using AI

Get instant AI answers from your Einhell GE-DP 900 Cut manual

Ask anything about the Einhell GE-DP 900 Cut. Answers come from this manual, with the pages they are based on.

GE-DP 900 Cut Maintenance Schedule

Remind me when maintenance is due
Quarterly
Check the floating switch function

For stationary installations, check that the floating switch operates correctly every three months.

Quarterly
Remove lint and fibrous particles

Use a water jet to remove any lint or fibrous particles trapped in the housing.

Quarterly
Clean the shaft bottom and walls

Remove sludge from the shaft bottom and clean the shaft walls every three months.

Quarterly
Clean deposits from the floating switch

Use clear water to remove any deposits from the floating switch.

After every use
Clean the pump with clear water

For portable applications, clean the equipment with clear water after every usage to remove debris.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend GE-DP 900 Cut?

Yes No

Frequently Asked Questions

A

It is designed for dirty wastewater and household wastewater. This includes water containing fibers, solids without stones, mechanically cleaned wastewater, and household wastewater with or without fecal matter. Do not use it with fuels, cleaning chemicals, aggressive liquids, stones, or abrasive materials.

Is this answer helpful?

A

The pump can move up to 16,000 liters of water per hour under suitable conditions. Actual output can be reduced by smaller hose diameters, long pipe runs, bends, lift height, blockages, or heavily contaminated water.

Is this answer helpful?

A

The maximum delivery head is 11.5 meters. This is the maximum vertical height under ideal conditions. Flow rate decreases as the lift height increases, so installation layout affects practical performance.

Is this answer helpful?

A

Yes. It uses an adjustable floating switch for automatic operation. The approximate switch-on height can be up to 50 cm and the switch-off height can be as low as 20 cm, provided the float has enough room to move freely.

Is this answer helpful?

A

No. It is not designed for continuous duty, such as permanent circulation in a pond. Extended continuous use can significantly reduce its expected service life.

Is this answer helpful?

A

Install it securely on the bottom of a sufficiently large shaft or suspend it using the carry handle. Never support it by the mains cable or discharge hose. Keep the base free from sludge, and raise the pump slightly on bricks when used over a muddy natural bottom.

Is this answer helpful?

A

Rinse portable installations with clean water after use. Remove fibers and deposits from the housing, clean the intake area, and inspect the floating switch. For fixed use, check the float and clean sludge from the shaft approximately every three months. Disconnect power before maintenance.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • 900 W motor delivers up to 16,000 l/h for efficient dirty-water drainage.
  • Maximum delivery head of 11.5 m supports pumping water to elevated discharge points.
  • Adjustable floating switch enables automatic on and off operation at selected water levels.
  • Suitable for fiber-containing wastewater and household wastewater, including fecal wastewater.
  • IPX8 protection and 7 m maximum submersion depth support submerged drainage work.
VS

Disadvantages

  • Not intended for continuous operation, such as permanent pond circulation.
  • Must not pump stones, aggressive chemicals, fuels, or abrasive substances.
  • Maximum water temperature is limited to 35 C.
  • Requires regular cleaning of the intake, float switch, shaft, and possible deposits.
  • Not suitable for swimming pools or water areas occupied by people or animals.
M: gpt-5.6-terra

Product Specification

Power

900 W

Flow rate

4,227 gal/h

Head height

37.73 ft

Submersion depth

22.97 ft

Hose connection

2 in

Special features

without tank

Cable length

32.81 ft

Weight

22.38 lb

M: gpt-5.6-terra

Product Description

Einhell GE-DP 900 Cut Electric Dirty Water Submersible Pump - Read, Download & Print Free

The Einhell GE-DP 900 Cut Electric Dirty Water Submersible Pump - Read, Download & Print Free is a capable solution for moving dirty water around the home and garden. Designed for demanding drainage jobs, this 900 W submersible pump handles wastewater containing fibers, solids without stones, and household wastewater, including water with fecal matter. It is suited to drainage pits, flooded areas, utility spaces, and other locations where reliable water transfer is needed.

Strong performance for dirty-water applications

With a maximum pumping rate of 16,000 liters per hour, the GE-DP 900 Cut is built to clear substantial volumes of water efficiently. Its maximum delivery head of 11.5 meters supports pumping water upward when a drainage point is above the collection area. The pump can be submerged to a depth of 7 meters and works with water temperatures up to 35 C.

The unit includes a 50 mm, or 2 inch, hose connection, supporting a wide outlet path for better flow. Using the largest suitable hose or pipe diameter helps achieve the best pumping performance. Its intake design and cutting-capable internal components are intended for wastewater where fibrous material may be present, while stones and aggressive or abrasive liquids must always be avoided.

Automatic control with a floating switch

A built-in floating switch helps automate operation according to the water level. The switch-on point can reach approximately 50 cm, while the switch-off point can be set as low as approximately 20 cm. This adjustability helps tailor the pump to the available shaft or container space.

Correct float positioning is essential for dependable operation. The float needs enough movement room, and it should not touch the bottom before the pump switches off. This reduces the risk of dry running, which can damage the equipment. The minimum water level for start-up is 230 mm, while the minimum suction height is 75 mm.

Installation and care considerations

The pump may be installed with a rigid pipe or flexible hose line. It must rest securely on the shaft bottom or be supported by its carry handle, never by the power cable or discharge hose. In muddy locations, placing it slightly above the base on bricks can help keep the intake clear.

Routine cleaning is important, especially after portable use. Rinse the housing with clean water, remove trapped fibers, and check the float switch regularly. For fixed installations, inspect the float switch and clean sludge from the pit about every three months. Wear gloves if cleaning the impeller area because the blades are sharp.

Note: Use a properly earthed 220-240 V, 50 Hz outlet protected by an RCD rated at 30 mA or less. Do not use the pump in pools or bodies of water where people or animals are present.