6. Operation
6.1 Using for the fi rst time
•
Install the equipment on a solid and level
surface.
•
Remove the ventilation screw (6).
•
Unscrew the coarse filter screw (4) using the
supplied wrench (10) and remove the coarse
filter (12) together with the non-return valve
(13) as shown in Figure 3. Now you can fill the
pump housing with water via the coarse filter
screw (4). Filling the intake line accelerates
the intake process.
•
Assemble in reverse order.
•
Open the discharge line.
•
Connect the mains cable.
•
The priming operation starts automatically.
•
After finishing the work, pull out the power
plug of the equipment.
6.2 LED indicator and fl ow switch
The fl ow switch cannot be adjusted or switched,
it is fully automatic. There are only 3 LEDs which
indicate its operating status. (Figure 4)
Green and yellow are lit:
The pump is in operation and starts up immedia-
tely; a consumer for drawing off transport fl uid is
open.
Green and red are lit:
1. The pump is building up pressure (e.g. a
water tap is closed) and then switches off au-
tomatically.
2. The pump is running dry without transport
fl uid. The fl ow switch will make 3 attempts to
eliminate the dry running before the dry run-
ning guard fi nally trips.
Green is lit, red is fl ashing:
The dry running guard has tripped; it is no longer
possible to draw in the transport fl uid. Use the
pump’s operating manual to fi nd the cause of the
fault (e.g. a leaking intake line) and rectify it. Then
restart the pump by pressing the Reset button on
the fl ow switch.
6.3 Intake pressure gauge
If the pump has been started up correctly, it will
pump water and the indicator on the intake pres-
sure gauge in the coarse fi lter screw (4) will rise
to the applicable suction height. During operation
the current suction height can be read off the in-
take pressure gauge (4). (Figure 5)
If the pump fails to pump any water when a pri-
ming attempt is made and the value on the intake
pressure gauge stagnates or stays at 0 m, this
means that there is a problem on the intake side.
Check all connections and the suction hose for
possible leaks. Filling the pump with water can
help the priming attempt. As a basic principle, we
recommend the use of a suction set with suction
hose, intake cage and non-return valve.
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
The equipment is almost completely maintenance
free. In order to ensure a long service life, howe-
ver, we recommend that you regularly check and
care for the product.
Danger!
The equipment must be disconnected from the
power supply (pull the power plug) prior to perfor-
ming any maintenance.
8.1 Servicing
•
If the equipment becomes clogged, connect
the discharge line to the water line and dis-
connect the suction hose. Open the water
line. Switch on the equipment several times
for approx. two seconds. This should resolve
the majority of clog-related problems.
•
There are no parts inside the equipment
which require additional maintenance.
8.2 Cleaning the coarse fi lter insert
•
Clean the coarse filter insert at regular inter-
vals, and replace it if necessary.
•
Remove the coarse filter screw (4) and coar-
se filter (12) together with the non-return val-
ve (13) (Figure 3).
•
Do not use abrasive cleaning agents or petrol
to clean the coarse filter and the non-return
valve.
•
Clean the coarse filter and the non-return val-
ve by tapping them on a flat surface. In cases
Anl_GE_AW_1042_FS_SPK9.indb 18Anl_GE_AW_1042_FS_SPK9.indb 18 02.08.2019 08:16:0902.08.2019 08:16:09

Chat with your Einhell GE-AW 1042 FS manual using AI

Get instant AI answers from your Einhell GE-AW 1042 FS manual

Ask anything about the Einhell GE-AW 1042 FS. Answers come from this manual, with the pages they are based on.

GE-AW 1042 FS Maintenance Schedule

Regularly
Clean the coarse filter insert

Remove the filter screw and take out the coarse filter and non-return valve. Tap them on a flat surface to clean. Replace if necessary.

Show in the manual (page 18)
Before winter storage or long inactivity
Flush and drain pump before storage

Rinse the pump thoroughly with water, empty it completely, and store it dry to prevent damage during periods of non-use or freezing temperatures.

Show in the manual (page 19)
After long stoppages
Check rotor rotation after idle time

Briefly switch the pump on and off to ensure the rotor turns correctly before resuming normal operation.

Show in the manual (page 19)
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend GE-AW 1042 FS?

Yes No
0
User Pic

Hans Mueller

5 months ago

How long does it take for water to resume flowing after turning the garden sprayer back on?

0
User Pic

Manual.ly

5 months ago

The pump is designed to shut off immediately when water flow stops and restarts automatically within approximately 2 seconds once you turn the sprayer back on. This delay ensures proper operation and prevents dry running.

M: QW-35-FL
M: QW-35-FL
0
User Pic

Julia Schmidt

7 months ago

Does the pump automatically stop when I pause spraying?

M: QW-35-FL

Frequently Asked Questions

A

No, the Einhell GE-AW 1042 FS is not designed for transporting drinking water. It is intended for clear water, rainwater, or light soapy water for irrigation and service water supply.

Is this answer helpful?

A

The pump features an automatic dry-running protection system. If it detects no water, it will shut off after three attempts to prime itself. You must then locate the issue, fix leaks, and press the reset button to restart.

Is this answer helpful?

A

Remove the coarse filter screw using the supplied wrench. Take out the filter and non-return valve. Tap them on a flat surface to remove dirt, or wash with soapy water if heavily soiled. Rinse with clean water and let dry before reassembly.

Is this answer helpful?

A

The maximum suction height for this pump is 8 meters. For best results, install the suction hose so it rises continuously from the water source to the pump without dips that could trap air.

Is this answer helpful?

A

Yes, but you must drain the pump completely before storing it in freezing temperatures. Residual water can freeze and crack the casing. Store in a dry place between 5 and 30 degrees Celsius.

Is this answer helpful?

A

Yes, the motor includes a built-in temperature controller. If the motor overheats due to overload or blockage, it will automatically switch off. Once it cools down, the pump will restart automatically.

Is this answer helpful?

A

The Einhell GE-AW 1042 FS requires a standard mains connection of 220 to 240 volts at 50 Hz. Ensure your outlet has a minimum fuse rating of 10 amperes for safe operation.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Automatic dry-running protection prevents motor damage
  • High flow rate of 4200 liters per hour for efficient watering
  • LED indicators provide clear operational status feedback
  • Includes coarse filter and non-return valve for easy setup
  • Compact design with a convenient carry handle
VS

Disadvantages

  • Not suitable for pumping drinking water
  • Maximum water temperature limited to 35 degrees Celsius
  • Cannot be used for commercial or industrial applications
  • Suction height limited to 8 meters maximum
  • Requires manual priming for initial start-up
M: QW-35-FL

Product Specification

Power

1050W

Flow rate

1110 gal/h

Head

157.48ft

Suction height

26.25ft

Pressure

69.31psi

Pressure connection

1"

Suction connection

1 1/4"

Features

without tank

Cable length

32.81ft

Weight

24.25lbs

M: QW-35-FL

Product Description

Einhell GE-AW 1042 FS: The Ultimate Solution for Home Water Management

The Einhell GE-AW 1042 FS Electric Domestic Water Pump is a robust and versatile tool designed to simplify water management tasks in your garden and home. This automatic domestic water system is engineered to handle irrigation, lawn sprinklers, and general water supply needs with ease. Whether you need to draw water from ponds, streams, rainwater barrels, or wells, this pump delivers reliable performance.

Equipped with a powerful 1050-watt motor, the unit can achieve a maximum delivery head of 48 meters and a flow rate of 4200 liters per hour. Its intelligent dry-running protection feature automatically shuts down the motor if no water is detected, preventing damage and extending the lifespan of the device. The LED indicator provides clear status updates, showing whether the pump is running, building pressure, or has triggered a safety shutdown.

Installation is straightforward thanks to the included connection adapter and pre-filter. The system allows for easy priming by filling the housing with water before operation. A built-in thermostat ensures the motor remains cool even under heavy loads, while the IPX4 protection rating guards against splashing water. This pump is ideal for clear water, rainwater, and light soapy water, making it perfect for seasonal gardening tasks.

Maintenance is minimal, requiring only occasional cleaning of the coarse filter to ensure optimal suction. By keeping the intake line free of debris and ensuring all connections are tight, you can enjoy years of trouble-free service. Remember to drain the pump completely before winter storage to prevent frost damage.

Key Notes

  • Always use the provided wrench to remove the coarse filter screw for maintenance.
  • Ensure the suction hose rises continuously to the pump to avoid air locks.
  • Do not use this pump for drinking water or aggressive liquids like acids.
M: QW-35-FL