3. Proper use
The equipment you have purchased is designed
to pump water with a maximum temperature of
35 °C. This equipment must never be used for
other liquids, especially not for engine fuels,
cleaning agents and other chemically-based
products!
The equipment can be used wherever you want to
move water, e.g. in the house, in the garden, and
for many other applications. It must not be used to
operate swimming pools!
If you want to use the equipment in bodies of wa-
ter with a natural, muddy bottom, place the equip-
ment in a slightly elevated position, e.g. on bricks.
The equipment is not designed for continuous
operation, e.g. as a circulating pump in a pond. In
this case the equipment’s anticipated life will be
greatly shortened because the equipment was
not designed for continuous loading.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
The water may be contaminated by escaping lub-
ricating oil/lubricant.
4. Technical data
Mains connection ....................220-240 V ~ 50 Hz
Power rating ............................................... 500 W
Max. pumping rate .................................12000 l/h
Max. delivery head ......................................... 8 m
Max. submersion depth .................................. 5 m
Max. water temperature ............................... 35°C
Hose connection ..................................................
..................... approx. 42 mm (1¼ “) female thread
Max. size of foreign bodies: ....................Ø 10 mm
Switching point height: ON .....max. approx. 50 cm
Switching point height: OFF ....min. approx. 10 cm
Protection type. .............................................IPX8
5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
5.1 Installation
The equipment can be installed either:
•
Stationary with a rigid pipe line
or
•
Stationary with a flexible hose line
Notice!
Before you use the pump, clarify any possible
special conditions which need to be fulfi lled for
the installation!
For example, additional safety measures may be
needed if damage to property could result from a
power failure, soiling or a defective gasket.
Examples of such safety measures:
Pumps running in parallel on a separately protec-
ted power circuit, moisture sensors for switching
off the pumps, and similar safety arrangements.
Be sure to consult a professional plumber if you
have any doubt.
Matching hose connectors for connecting the
discharge line are included among the items
supplied.
Use the adapter which matches the hose diame-
ter (see Fig. 2).
To assemble, proceed as follows:
•
Screw the appropriate hose connector hand-
tight to the pressure connection (Fig. 1/Item
2).
•
Connect the delivery hose to the hose con-
nector and secure the hose, e.g. with a hose
clip.
When installing, never hang the equipment by the
discharge line or by the power cable. The equip-
ment must be hung up with the provided carry
handle or it must rest on the bottom of the shaft.
To ensure that the equipment works properly, the
bottom of the shaft always must be free of sludge
and other accumulations of dirt. If the water level
is too low, the sludge in the shaft can quickly dry
out and hinder the equipment from starting. It is
necessary therefore to check the equipment regu-
larly (carry out trial start-ups).
The pump shaft should be large enough.
Anl_GC-DP_5010_G_SPK9.indb 17Anl_GC-DP_5010_G_SPK9.indb 17 05.12.2017 08:19:5505.12.2017 08:19:55

Chat with your Einhell GC-DP 1020 N manual using AI

Get instant AI answers from your Einhell GC-DP 1020 N manual

Ask anything about the Einhell GC-DP 1020 N. Answers come from this manual, with the pages they are based on.

GC-DP 1020 N Maintenance Schedule

Remind me when maintenance is due
Every 3 months
Check floating switch operation

For stationary installation, check that the floating switch operates correctly every three months.

Show in the manual (page 17)
Every 3 months
Clean shaft bottom and walls

Remove sludge from the shaft bottom and clean the shaft walls to ensure proper function.

Show in the manual (page 17)
After every use
Clean pump with clear water

For mobile applications, clean the equipment with clear water after every usage to prevent clogging.

Show in the manual (page 17)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend GC-DP 1020 N?

Yes No

Frequently Asked Questions

A

The pump has a maximum delivery rate of 22,000 litres per hour. Actual output can be lower when using narrow hoses, long pipe runs, bends, or restrictive fittings.

Is this answer helpful?

A

It can handle foreign bodies with a maximum diameter of 40 mm. Regular cleaning is still important when pumping heavily contaminated water or water containing fibrous material.

Is this answer helpful?

A

No. It must not be operated in swimming pools, paddling pools, or other water areas where people or animals may be present during operation.

Is this answer helpful?

A

The float switch controls automatic start and stop operation according to the water level. Its position can be adjusted in the holder, but it needs enough free movement and should not touch the base before shut-off.

Is this answer helpful?

A

Manual mode makes the pump run continuously, but only under supervision. Switch it off immediately when water no longer leaves the discharge line to avoid dry running.

Is this answer helpful?

A

Clean it with clear water after portable use. For stationary setups, check the float switch, remove shaft sludge, and clean deposits about every three months. Clean the intake cage and impeller if flow decreases.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • High 22,000 l/h maximum flow rate supports rapid drainage of flooded or waterlogged areas.
  • Handles dirty water with particles up to 40 mm, making it suitable for debris-filled drainage tasks.
  • Adjustable float switch enables automatic water-level control or supervised manual operation.
  • Offers a 9 m maximum delivery head and 7 m maximum submersion depth for versatile placement.
  • Universal hose connection helps adapt the pump to different discharge hose sizes.
VS

Disadvantages

  • Not suitable for continuous operation, such as permanent pond circulation.
  • Maximum water temperature is limited to 35 C.
  • Must not pump fuels, cleaning products, aggressive chemicals, or abrasive materials.
  • Manual mode requires constant supervision to prevent dry running.
  • A hose clamp is needed for flexible hose installation but is not included.
M: gpt-5.6-terra

Product Specification

Features

tankless

Cable length

32.81 ft

M: gpt-5.6-terra

Product Description

Einhell GC-DP Electric Dirty Water Submersible Pump Manual

The Einhell GC-DP 9040 N is a powerful dirty water submersible pump designed to move large volumes of water from flooded areas, drainage shafts, garden spaces, and household water collection points. With a 900 W motor and a maximum delivery rate of 22,000 litres per hour, it is built for demanding clean-up tasks where ordinary water pumps may struggle. This Einhell GC-DP Electric Dirty Water Submersible Pump Manual overview highlights the key capabilities, installation considerations, and practical care points for reliable use.

Built for dirty water drainage

This pump can process water containing particles up to 40 mm in diameter, making it suitable for rainwater mixed with dirt, small debris, or mud. It offers a maximum delivery head of 9 m and can be submerged to depths of up to 7 m. These specifications provide useful flexibility for emptying basements, construction pits, tanks, and deep drainage areas.

A universal hose connection supports practical hose setup, while the largest suitable hose diameter helps preserve the highest possible flow rate. Smaller hoses and restricted pipework can reduce output. Flexible hoses should be secured with a suitable hose clamp for a stable connection.

Automatic control with a float switch

The integrated float switch allows the pump to start and stop based on the water level. Its switching position can be adjusted through the float switch holder, helping users match operation to the available space and drainage needs. The approximate switch-on height is up to 50 cm, while switch-off can occur from around 5 cm.

Manual operation is also possible by securing the float switch in its continuous-running position. However, this setting requires supervision because the pump must not run dry. Disconnect the power supply as soon as water stops flowing from the discharge hose.

Installation and safe operation

Place the pump firmly on the bottom of a sufficiently sized shaft or suspend it only by its carrying handle. Never support it by the power cable or discharge line. For muddy natural surfaces, raising the pump slightly on bricks can help prevent the intake area from becoming blocked.

The pump is intended only for water up to 35 C. Do not use it with fuel, cleaning agents, aggressive chemicals, or abrasive liquids. It is not intended for continuous-duty circulation, such as permanent pond circulation, and it must not be used in swimming pools or where people or animals are present in the water.

Note: Use a properly grounded 230 V, 50 Hz outlet protected by an RCD rated at no more than 30 mA. Keep plug connections dry and protected from flooding.

Care notes

Rinse the pump with clean water after portable use. For fixed installations, check the float switch and remove sludge from the shaft every three months. Clean the intake cage and impeller when performance drops, and store the unit in a dry, frost-free location between 5 C and 30 C.