Manual.ly Logo

Ective SSP 100 Manual

0.0 · 0 Ratings

PDF manual · 24 Pages

English

M: OA-GPT-5-NAN
page

/ 24

Loading...
dd7b63ab1cfefe5c85bcabdedd1f739cb482 page e
12 ECTIVE MSP & SSP
Welcome!
Thank you for choosing the ECTIVE solar module!
Please read this manual carefully before installing and using the device.
Also make sure to read and follow the instructions for any charge controller
or any other devices you connect to the solar module.
ECTIVE stands for power supply solutions at an
unbeatable price-performance ratio.
Explore our brand and products at
ECTIVE.DE
1. General Information About this Manual
1.1 Subject and Purpose of these Instructions
This manual presents all relevant information for the safe installation of
ECTIVE MSP and SSP solar modules. Expert knowledge is required for
the installation and commissioning of photovoltaic systems. Therefore,
you should read this manual carefully and take into account all the safety
instructions listed here when installing the modules. If you have any
questions about the products, simply contact our service team by mail
(info@ective.de). Keep the manual in a safe place for future reference, such
as maintenance and care of the solar module.

Chat with your Ective SSP 100 manual using AI

Get instant AI answers from your Ective SSP 100 manual

Ask anything about the Ective SSP 100. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend SSP 100?

Yes No

Frequently Asked Questions

A

The SSP 100 delivers 100 watts peak from monocrystalline cells and is intended for small off-grid applications like campers, boats, tiny homes, free-standing arrays and roof installations where a lightweight, compact panel is advantageous.

Is this answer helpful?

A

Yes — the FLEX version of the SSP/MSP series is designed for curved or imperfect surfaces and can be bonded with recommended vehicle adhesives after thorough surface cleaning. Observe adhesive temperature and humidity limits (approx. −20 °C to +60 °C, non-condensing).

Is this answer helpful?

A

Always use a qualified installer, cover modules during work to prevent live generation, use insulated tools, avoid work in rain or high wind, use fall protection on roofs, and follow local grounding and electrical regulations to prevent shock and equipment damage.

Is this answer helpful?

A

Use UV-resistant solar cable, recommended 4 mm² per module and rated current >10 A. Multiply the module’s short-circuit current and open-circuit voltage by 1.25 when determining fuse sizes and component voltage ratings to allow safety margins.

Is this answer helpful?

A

Clean glass with water and a soft cloth or sponge (no abrasives), inspect all electrical connections every six months for looseness or corrosion, and consult a professional if issues occur. Replace defective bypass diodes if identified.

Is this answer helpful?

A

Check all cable connections, measure open-circuit voltage per module, cover all modules, isolate the suspect module and measure again; if voltage is roughly half the nominal value, a bypass diode may be defective. Also look for faulty terminations or wiring issues.

Is this answer helpful?

A

Dispose or recycle the module according to local WEEE regulations; local recycling centers are typically required to accept solar modules. Also recycle packaging materials per local rules and follow any region-specific electronic-equipment laws.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Lightweight 100Wp monocrystalline design ideal for mobile and small installations.
  • Flexible mounting options including adhesive bonding for curved surfaces (FLEX variants).
  • Simple maintenance: easy cleaning and biannual connection checks.
  • Clear electrical guidance: use 4 mm² cable, multiply Isc and Voc by 1.25 for sizing.
  • Includes frame features for drainage, ventilation and equipotential bonding points.
VS

Disadvantages

  • Requires qualified installer for safe installation and grid connection approvals.
  • Vulnerable to damage if dropped, walked on, or improperly clamped/drilled.
  • Bypass diodes can fail under shading and must be replaced with correct type.
  • Limited warranty (3 years voluntary) compared with some industry long-term guarantees.
  • Adhesive-mounted installations depend on surface prep and environmental limits.
M: OA-GPT-5-NAN

Product Specification

Note

Prices partly include 0%-VAT tax rates for AT and DE

Number of Modules

1

Technology

Monocrystalline

Power (Pmax)

100Wp (STC)

Nominal Voltage (Vmp)

18.14V (STC)

Max. Output Current (Imp)

5.51A (STC)

Open-Circuit Voltage (Voc)

21.57V (STC)

Short-Circuit Current (Isc)

5.84A (STC)

Efficiency

21.4%

Cells

132

Connector

MC4

Protection Class

IP67

Operating Temperature

-40°F to +185°F

Dimensions

26.38x32.68x0.98in (WxHxD)

Weight

5.89lb

Area incl. Frame

6.03ft^2

Yield

16.71Wp/ft^2 (STC)

Performance Guarantee

min. 80.0% after 5 years (corresponds to 80Wp (STC))

M: OA-GPT-54-NAN

Product Description

Ective SSP 100 lightweight, 100Wp Manual

The Ective SSP 100 lightweight, 100Wp is a compact, portable monocrystalline solar module designed for dependable off-grid power on campers, boats, tiny homes and small ground arrays. Engineered for easy installation and robust daily use, this 100Wp panel prioritizes low weight and flexible mounting options while maintaining solid electrical performance. It’s part of the ECTIVE SSP/MSP family known for practical, cost-effective power solutions.

Product overview

Lightweight and handable, the SSP 100 delivers 100 watts peak output from monocrystalline cells optimized for small systems. Its thin, durable frame and optional FLEX variants allow mounting on curved or irregular surfaces using recommended adhesives or modular mounting kits. The module includes ventilation and drainage openings in the frame, predrilled equipotential bonding points, and standard solar connectors for quick wiring.

The SSP 100 is suitable for free-standing arrays, roof installations on houses or vehicles, and pole or mast applications. For vehicle roofs, ECTIVE recommends plastic profiles and specific mounting sets that minimize wind noise and aerodynamic drag while offering secure fixation. Designed for self-cleaning at tilt angles above 15°, the panel’s construction tolerates normal environmental loads but requires correct anchoring to handle snow and wind stresses.

Installation & electrical notes

Installation should be performed by qualified personnel. The manual highlights safe handling (cover modules during work to prevent live generation, use insulated tools, avoid working in rain) and recommends matching modules of the same type in a system. Use UV-resistant solar cables (recommended 4 mm²) and proper connectors. Multiply datasheet short-circuit and open-circuit values by 1.25 for sizing fuses and component ratings. Observe local grounding and grid-connection regulations; grid feed-in normally requires approval and a licensed electrician for final connection.

Testing before commissioning includes measuring open-circuit voltage and short-circuit current per string and verifying values against expected (1.25 factor for short-circuit checks). The manual details wiring bend radii, strain limits (max 50 N), and spacing requirements between modules and mounting rails.

Maintenance & troubleshooting

Routine care is simple: clean glass with water and a soft cloth, inspect electrical connections every six months, and replace defective bypass diodes if shading-induced reverse currents cause damage (provide module serial number when ordering replacements). For low-voltage symptoms, the manual guides stepwise checks of connections and diode function.

Notes

  • Warranty: voluntary 3-year manufacturer warranty plus statutory rights.
  • Avoid drilling additional holes in frame or glass; don’t remove glued labels.
  • Adhesives for FLEX models rated roughly −20 °C to +60 °C (non-condensing).
  • Recycle modules per WEEE (EU) rules; packaging should be disposed of responsibly.
M: OA-GPT-5-NAN