Manual.ly Logo

Eaton CPAD-00/215 Manual

0.0 · 0 Ratings

PDF manual · 4 Pages

English

M: QW-35-FL
page

/ 4

Loading...
f50b3d7a04fd616296a8f767995bc46a8fc3 page 4
EU
- type examination performed by:
TÜV Austria Services GmbH, Notified Body
1230 Vienna, Deutschstrasse 10, Austria
Affixing date of CE mark:
2014
Doc.Id.:
CSAU-0101-10.._CSAU-0101-16.._171117
Senior Vice President Director Quality
General Manager & Systems
Friedrich Schröder
Fernando Ceccarelli
Declaration of Conformity
We, EATON Industries (Austria) GmbH
3943 Schrems, Eugenia 1
Austria
declare under our sole responsibility that the product (family)
Eaton - Switching actuator,
CSAU-01/01-10.., CSAU-01/01-16.. (contains RF-Modul
CSCZ-01/xx)
(the declaration of conformity applies to all
listed types within our actual product catalogue)
provided that it is installed, maintained and used in the
application intended for, with respect to the relevant manufacturers
instructions, installation standards and “good engineering practices”
complies with the provisions of Council directive(s):
RED Directive 2014/53/EU
RoHS Directive 2011/65/EU
based on compliance with following standard(s):
EN 301489-3 V2.1.1, EN 300220-2 V3.1.1, EN 60669-2-1:2010;
EN 50428:2005 + A1:2007 + A2:2009, EN 50491-5-1:2010,
EN 50491-5-2:2010, EN 60950-1:2006 + A11:2009 + A1:2010 +
A12:2011 + A2:2013, EN 62479:2010, EN 50581:2012
17.11.2017
EU
- type examination performed by:
TÜV Austria Services GmbH, Notified Body
1230 Vienna, Deutschstrasse 10, Austria
Affixing date of CE mark:
2003
Doc.Id.:
CTAA-…_171117
Senior Vice President Director Quality
General Manager & Systems
Friedrich Schröder
Fernando Ceccarelli
Declaration of Conformity
We, EATON Industries (Austria) GmbH
3943 Schrems, Eugenia 1
Austria
declare under our sole responsibility that the product (family)
Eaton - Push Button,
CTAA-…
(the declaration of conformity applies to all
listed types within our actual product catalogue)
provided that it is installed, maintained and used in the
application intended for, with respect to the relevant manufacturers
instructions, installation standards and “good engineering practices”
complies with the provisions of Council directive(s):
RED Directive 2014/53/EU
RoHS Directive 2011/65/EU
based on compliance with following standard(s):
EN 301489-3 V2.1.1, EN 300220-2 V3.1.1, EN 50491-5-1:2010,
EN 50491-5-2:2010, EN 60950-1:2006 + A11:2009 + A1:2010 +
A12:2011 + A2:2013, EN 62479:2010, EN 50581:2012
17.11.2017
© 2020 by Eaton Industries (Austria) GmbH
Eugenia 1, 3943 Schrems, Austria
www.eaton.eu/documentation
All Rights Reserved, Printed in Austria
136211193.indd 4136211193.indd 4 11.02.2020 12:06:3511.02.2020 12:06:35

Chat with your Eaton CPAD-00/215 manual using AI

Get instant AI answers from your Eaton CPAD-00/215 manual

Ask anything about the Eaton CPAD-00/215. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend CPAD-00/215?

Yes No

Frequently Asked Questions

A

The device operates at 868.3 MHz radio frequency for reliable indoor transmission.

Is this answer helpful?

A

The included CR2450N 3V battery typically lasts ten years under normal conditions.

Is this answer helpful?

A

The unit handles up to 10 amperes for resistive, inductive, capacitive and LED loads.

Is this answer helpful?

A

Yes, this switch is fully compatible with xComfort systems and supports ESM.

Is this answer helpful?

A

It requires 230 VAC with a tolerance of plus ten percent to minus fifteen percent.

Is this answer helpful?

A

Yes, the degree of protection is rated IP20 for indoor use only.

Is this answer helpful?

A

It complies with RED Directive 2014/53/EU and RoHS Directive 2011/65/EU.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Long battery lifetime reduces maintenance needs significantly over time.
  • Patented Hybrid Zero-cross switching minimizes electrical interference.
  • High load capacity supports various lighting types including LEDs up to 10A.
  • Compatible with xComfort systems for expanded functionality options.
  • Low standby power consumption aids overall energy savings goals.
VS

Disadvantages

  • Indoor rating limits usage to protected environments only.
  • Sensor temperature range restricts extreme cold or heat zone usage.
  • Requires specific frequency coordination with other RF devices nearby.
  • Limited documentation might complicate initial troubleshooting steps sometimes.
  • Voltage tolerance requires careful mains supply monitoring initially.
M: QW-35-FL

Product Specification

Type

Actuator

Standard

Radio Bus (868 MHz)

Function

Switch Actuator (on/off)

Features

IP20, battery-powered (1x CR2450N)

M: QW-35-FL

Product Description

Revolutionizing Smart Switching With Reliable Hardware

Modern buildings rely heavily on automation systems that provide consistent control without excessive complexity. The Eaton CPAD-00/215 Wireless Second Switch represents a significant leap in single-way radio switching capabilities. It facilitates easy integration into existing electrical networks while offering robust performance metrics. Installers appreciate the compact design that fits standard DIN rails efficiently. This device ensures seamless operation for residential and commercial lighting projects alike.

Electrical Performance and Load Capacity

Power supply requirements remain standard for most installations at 230 VAC with a tolerance of plus ten percent or minus fifteen percent at 50 Hz frequency. The unit manages resistive, inductive, capacitive and LED loads effectively up to ten ampere maximum rating. Eaton implements patented Hybrid Zero-cross switching technology which drastically reduces electromagnetic interference during switching events. Standby power consumption stays low at 230 milliwatts typical value saving electricity.

Battery Life and Wireless Range

Maintenance costs drop significantly because the included CR2450N 3V battery lasts typically ten years before replacement. Radio frequency transmission occurs at 868.3 MHz ensuring reliable signal penetration through walls. The system supports xComfort compatibility and ESM protocols for advanced management scenarios. Ingress protection level IP20 indicates suitability for dry indoor locations only. Temperature ratings for the actor range from minus five to plus fifty-five degrees Celsius. Sensors function best within positive five to positive forty-five degrees Celsius range.

Compliance and Safety Standards

Quality assurance processes include EU type examination performed by TUV Austria Services GmbH. Affixing date of CE mark occurred in 2014 confirming regulatory adherence. The product meets RED Directive 2014/53/EU and RoHS Directive 2011/65/EU provisions fully. Adherence to standards like EN 301489 and EN 60669 ensures safety. Technicians often refer to the Eaton CPAD-00/215 Wireless Second Switch, Single-way, Radio Switch Manual for precise calibration details during commissioning. Following proper procedures prevents errors.

Essential Notes for Users

Always disconnect power before connecting wires to prevent shock hazards. Check signal strength periodically to maintain optimal communication links. Keep environmental temperature within specified operating limits to extend component lifespan. Ensure ventilation spaces exist around the device if enclosed in cabinets. Use original spare parts for any future repair attempts to maintain warranty coverage. Regular cleaning keeps contacts free from dust accumulation which could cause resistance issues. These steps guarantee long-term satisfaction with the installed system components.

M: QW-35-FL