The device operates at 868.3 MHz radio frequency for reliable indoor transmission.
Is this answer helpful?
The included CR2450N 3V battery typically lasts ten years under normal conditions.
Is this answer helpful?
The unit handles up to 10 amperes for resistive, inductive, capacitive and LED loads.
Is this answer helpful?
Yes, this switch is fully compatible with xComfort systems and supports ESM.
Is this answer helpful?
It requires 230 VAC with a tolerance of plus ten percent to minus fifteen percent.
Is this answer helpful?
Yes, the degree of protection is rated IP20 for indoor use only.
Is this answer helpful?
It complies with RED Directive 2014/53/EU and RoHS Directive 2011/65/EU.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Long battery lifetime reduces maintenance needs significantly over time.
- Patented Hybrid Zero-cross switching minimizes electrical interference.
- High load capacity supports various lighting types including LEDs up to 10A.
- Compatible with xComfort systems for expanded functionality options.
- Low standby power consumption aids overall energy savings goals.
Disadvantages
- Indoor rating limits usage to protected environments only.
- Sensor temperature range restricts extreme cold or heat zone usage.
- Requires specific frequency coordination with other RF devices nearby.
- Limited documentation might complicate initial troubleshooting steps sometimes.
- Voltage tolerance requires careful mains supply monitoring initially.
Product Specification
Type
Actuator
Standard
Radio Bus (868 MHz)
Function
Switch Actuator (on/off)
Features
IP20, battery-powered (1x CR2450N)
Product Description
Revolutionizing Smart Switching With Reliable Hardware
Modern buildings rely heavily on automation systems that provide consistent control without excessive complexity. The Eaton CPAD-00/215 Wireless Second Switch represents a significant leap in single-way radio switching capabilities. It facilitates easy integration into existing electrical networks while offering robust performance metrics. Installers appreciate the compact design that fits standard DIN rails efficiently. This device ensures seamless operation for residential and commercial lighting projects alike.
Electrical Performance and Load Capacity
Power supply requirements remain standard for most installations at 230 VAC with a tolerance of plus ten percent or minus fifteen percent at 50 Hz frequency. The unit manages resistive, inductive, capacitive and LED loads effectively up to ten ampere maximum rating. Eaton implements patented Hybrid Zero-cross switching technology which drastically reduces electromagnetic interference during switching events. Standby power consumption stays low at 230 milliwatts typical value saving electricity.
Battery Life and Wireless Range
Maintenance costs drop significantly because the included CR2450N 3V battery lasts typically ten years before replacement. Radio frequency transmission occurs at 868.3 MHz ensuring reliable signal penetration through walls. The system supports xComfort compatibility and ESM protocols for advanced management scenarios. Ingress protection level IP20 indicates suitability for dry indoor locations only. Temperature ratings for the actor range from minus five to plus fifty-five degrees Celsius. Sensors function best within positive five to positive forty-five degrees Celsius range.
Compliance and Safety Standards
Quality assurance processes include EU type examination performed by TUV Austria Services GmbH. Affixing date of CE mark occurred in 2014 confirming regulatory adherence. The product meets RED Directive 2014/53/EU and RoHS Directive 2011/65/EU provisions fully. Adherence to standards like EN 301489 and EN 60669 ensures safety. Technicians often refer to the Eaton CPAD-00/215 Wireless Second Switch, Single-way, Radio Switch Manual for precise calibration details during commissioning. Following proper procedures prevents errors.
Essential Notes for Users
Always disconnect power before connecting wires to prevent shock hazards. Check signal strength periodically to maintain optimal communication links. Keep environmental temperature within specified operating limits to extend component lifespan. Ensure ventilation spaces exist around the device if enclosed in cabinets. Use original spare parts for any future repair attempts to maintain warranty coverage. Regular cleaning keeps contacts free from dust accumulation which could cause resistance issues. These steps guarantee long-term satisfaction with the installed system components.