Dimplex IRP Manual
PDF manual · 16 Pages
English

Quick check
Incorrect answer, please try again.
Chat with your Dimplex IRP manual using AI
Get instant AI answers from your Dimplex IRP manual
Ask anything about the Dimplex IRP. Answers come from this manual, with the pages they are based on.
Ask a Question
Do you recommend IRP?
Yes NoFrequently Asked Questions
The IRP 600W delivers a nominal heat output of 0.60 kW (600 W) suitable for supplemental or targeted heating of medium-sized rooms; performance depends on room insulation and layout.
Is this answer helpful?
Yes — the unit is rated IP44 for splash protection, but must be installed so it cannot be touched by a person in the bathtub or shower and must observe the required protection zones and minimum clearances; installation should follow local regulations.
Is this answer helpful?
The heater must be used with an external programmable room thermostat featuring weekly programming and adaptive start control (recommended: Dimplex DTB 2R) to enable efficient and compliant operation.
Is this answer helpful?
The IRP 600W includes an integrated overheat safety cutoff that automatically switches the unit off if obstructed or overheated; after the unit cools and the cause is cleared it will reset. It also requires proper mounting and installation to reduce risks.
Is this answer helpful?
Switch off and let the unit cool, set the room thermostat to OFF, then clean the exterior with a soft hand brush. Do not use liquids, scouring powders or chemical cleaners to avoid surface damage.
Is this answer helpful?
The IRP 600W can be mounted vertically or horizontally on walls or horizontally on ceilings using the supplied original brackets; if suspended from a ceiling use the IRP Cable Set accessory and always maintain the recommended minimum clearances.
Is this answer helpful?
The product includes a five-year warranty under Glen Dimplex terms. At end of life, the heater must not be disposed of with household waste and should be taken to a local electrical recycling or disposal facility.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Compact low-profile panel (1192 x 592 x 30 mm) that fits many interiors without occupying floor space.
- Radiant heating provides silent, dust-reducing warmth ideal for allergy-sensitive environments.
- IP44 splash protection allows bathroom installation when mounted outside reach and per regulations.
- Built-in overheat protection automatically shuts down if obstructed and resets after cooling.
- Five-year warranty gives long-term coverage and manufacturer support.
Disadvantages
- Requires fixed wiring and a qualified electrician for safe installation, increasing initial cost.
- Must be used with an external programmable thermostat to meet recommended control features.
- Minimum clearance requirements (including 500 mm front space) may limit placement options.
- Not to be covered or obstructed — users must ensure free airflow and keep objects away.
- Ceiling suspension needs additional IRP Cable Set accessory if required, adding expense.
Product Specification
Power
600W
Color
white
Special Features
Overheating protection
Protection Class
IP44
Mounting Type
Wall mounting, Ceiling mounting
Dimensions
46.93x23.31x1.18in (WxHxD)
Weight
20.72lb
Product Description
Glen Dimplex IRP 600W Manual: Product Overview
The Glen Dimplex IRP 600W is a slim infrared panel heater designed for efficient, silent room heating. With a low-profile design (1192 x 592 x 30 mm) and a weight of 9 kg, it offers gentle radiant warmth ideal for living rooms, offices, bathrooms (IP44 splash protection) and other enclosed spaces. The unit delivers a nominal heat output of 0.60 kW and is built to be mounted vertically or horizontally on walls or ceilings. Its surface and radiant technology provide a comfortable heat distribution without air circulation, reducing dust movement and noise.
Key Features and Use
The IRP 600W is made for fixed wiring and should be installed by a qualified electrician. It requires an external programmable room thermostat (recommended: Dimplex DTB 2R) that supports weekly programming and adaptive start control to maximize comfort and energy savings. The heater includes an integrated overheat protection that automatically cuts power if obstructed or overheated and resets after cooling.
Installation offers flexibility: use the supplied original brackets for wall or ceiling mounting, and maintain minimum clearances (including 500 mm clearance in front). For suspended ceiling installations, the IRP Cable Set accessory is recommended. The device is intended for room air heating only and must not be covered to avoid overheating.
Maintenance is straightforward — switch off and allow the unit to cool before cleaning; use a soft hand brush and avoid liquids or abrasive chemicals to protect the textured surface. The product comes with a five-year warranty and should be recycled at an appropriate disposal facility at end of life rather than thrown in household waste.
Practical Notes
- Ensure the mains voltage matches the type plate and provide a dedicated circuit where possible. Connection must include a disconnect with at least 3 mm contact opening per pole.
- Children under certain ages must be supervised around the heater and must not perform cleaning or maintenance. Keep the heater out of reach of persons in baths or showers.
- If the heater stops producing warmth, check the thermostat and supplying fuse; if the built-in thermal cut-out has activated, remove the cause, allow cooling, and the unit will reset.
Final Thought
The IRP 600W blends unobtrusive design, reliable safety features and efficient radiant heating control when paired with an appropriate room thermostat, making it a practical solution for targeted, low-noise heating in many indoor settings.
Notes:
- IP44 splash protection makes it suitable for bathrooms if installed outside the reach of occupants in the bath/shower and following local regulations.
- Use original mounting brackets and observe all minimum clearances to avoid fire or heat damage.
- Keep the appliance free from obstructions to prevent overload shutdown.