75aa155f28bb11e6a72fc43d65dc67dacbb5 page d
www.dimplex.de/en 1807/B EN-2
FPE 050E - FPE 200E English
1. Notes for the user
NOTE
Dear customer,
Keep these instructions in a safe place and pass them
on to possible future owners.
CAUTION!
This device can be used by children aged 8
and over and by persons with limited physical,
sensory or mental aptitude or lack of
experience and/or knowledge, providing they
are supervised or have been instructed in the
safe use of the device and understand the
associated potential dangers. Children must
not play with the device. Cleaning and user
maintenance may not be carried out by
children without supervision!
CAUTION!
Children younger than 3 years of age must be
kept away unless they are supervised
constantly. Children between the ages of 3
and 8 may switch the device on and off if they
are supervised or have been instructed in the
safe use of the device and have understood
the resulting dangers, providing that the
device is positioned or installed in its normal
place of use!
CAUTION!
Children between the ages of 3 and 8 may not
switch on the device, clean the device or carry
out maintenance!
CAUTION!
The device carries the symbol
shown on the right, which indicates
that the heating device must under
no circumstances be covered with
any objects.
CAUTION!
Some parts of the device can get very hot and
cause burns. Particular caution must be taken
with children or vulnerable people!
CAUTION!
Do not operate the heating device in rooms
where highly inflammable substances are
used (e.g. solvents).
CAUTION!
If the power cable is damaged, it must be
replaced by the manufacturer or after-sales
service representative or a person with
comparable qualifications for switching off
danger sources!
NOTE
Use device for room heating within enclosed rooms
only.
2. Assembly, installation, minimum
clearance
CAUTION!
Install the device in such a manner that it
cannot be touched by a person in the bathtub
or under the shower.
CAUTION!
Do not install the device directly below a wall
socket.
The minimum clearances must be observed.
In addition, a clearance of 1 meter is to be maintained
in front of the unit.
The heating device must be aligned horizontally and
installed on a vertical wall (see illustration).
All dimensions in mm.
During assembly, the safety area must be complied
with according to the current installation regulations.
The supply connection socket must be accessible after
installation.
Make sure that the inflow and outflow of air at the top
and bottom of the device are unimpeded
.
Model
A
(mm)
B
(mm)
C
(mm)
D
(mm)
E
(mm)
FPE 050E 145 242 117 270 104
FPE 100E 229 177 230
FPE 150E 263 319 264
FPE 200E 261 534 262
A
200
150
200
213
C
119
258
63
180
Supply lead
440
B
D
E

Chat with your Dimplex FPE manual using AI

Get instant AI answers from your Dimplex FPE manual

Ask anything about the Dimplex FPE. Answers come from this manual, with the pages they are based on.

FPE Maintenance Schedule

As needed
Clean the device exterior

Disconnect from mains and let cool. Wipe outside with a soft damp cloth. Do not use scouring powder or furniture polish.

As needed
Remove dust inside the device

Use a vacuum cleaner to remove dust accumulations from the outside of the unit.

M: QW-35-FL

Ask a Question

0/1000

Do you recommend FPE?

Yes No

Frequently Asked Questions

A

The FPE series comes in four nominal heat outputs: 0.5 kW, 1.0 kW, 1.5 kW and 2.0 kW, allowing selection according to room size and heating needs.

Is this answer helpful?

A

In automatic mode the controller senses room occupancy. While a person is detected the comfort temperature remains active; after 30 minutes of absence it lowers by 1°C, after one hour by 2°C and after more than 2 hours it reduces to the Eco temperature (factory 3.5°C reduction).

Is this answer helpful?

A

The heater includes an overheat protector that cuts power if airflow is blocked, a requirement for professional earthing and fixed wiring, and clear user warnings about covering the unit or operating near flammable substances.

Is this answer helpful?

A

Yes. The unit supports six programs (P1–P6). P1–P3 are factory-fixed time blocks; P4–P6 are user-configurable with up to three comfort and three Eco periods per program, assigned per weekday.

Is this answer helpful?

A

Window monitoring is factory-active and pauses heating when a window is open. Central pilot-wire temperature reduction may not function while a weekly program (P1–P6) is executing, so behavior depends on controller mode and schedule.

Is this answer helpful?

A

Disconnect mains and allow cooling before cleaning. Wipe the exterior with a soft damp cloth; do not use abrasive cleaners or polishes. Remove external dust deposits with a vacuum cleaner; internal work must be done by qualified personnel.

Is this answer helpful?

A

Yes—the FPE is IP24 splash-protected and can be wall-mounted in bathrooms, provided minimum clearance rules and safe mounting distances (including 1 m in front) are observed and it cannot be touched from a bathtub or shower.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Multiple power options (0.5–2.0 kW) to suit different room sizes.
  • Electronic controller with weekly program, presence detection and window monitoring for energy savings.
  • IP24 splash protection and slim wall-mounted design for bathrooms and compact spaces.
  • Low standby consumption (~0.5 W) and programmable comfort/Eco temperatures.
  • Safety features include earth requirement, overheat protection and configurable key lock.
VS

Disadvantages

  • Requires qualified electrician for fixed installation and earthing.
  • Pilot-wire central temperature reduction can be ineffective when weekly program runs.
  • Mounting needs strict clearance (including 1 m in front) which may limit placement options.
  • Some features (e.g., temperature limits, code lock setup) require menu navigation and hold-press operations.
  • Not suitable for rooms with highly flammable substances; must not be covered.
M: OA-GPT-5-NAN

Product Description

Glen Dimplex FPE Manual — Smart, Efficient Infrared Panel Heaters

Glen Dimplex FPE infrared panel heaters combine simple wall-mounted design with intelligent electronic control for reliable, energy-conscious room heating. Available in four power sizes (0.5, 1.0, 1.5 and 2.0 kW), the FPE series fits a range of rooms and installation needs. Each model is splash-protected (IP24), slim-profiled and supplied with a dedicated wall bracket for secure, horizontal mounting. The units are intended for indoor use only and must be installed on a vertical wall with minimum clearances and a 1 m frontal free zone for safe airflow.

Key features and user experience

The FPE heater is driven by an electronic room temperature controller with a clear display, six control keys and an LED. Modes include manual, automatic and weekly-program operation. Automatic mode adds presence detection (it keeps comfort temperature while the room is occupied and gradually reduces temperature during absence) and window monitoring (pauses heating if a window is open). Manual mode allows selecting comfort, Eco (preset or adjustable offset) and frost-protect temperatures. The weekly program supports six program presets (P1–P6) with P1–P3 fixed and P4–P6 configurable, allowing up to three comfort and three reduced periods per program.

Safety and convenience are central: an overheat protector shuts the unit off if air circulation is blocked; the device must be earthed and connected by a qualified electrician; and children’s usage and cleaning guidance are clearly specified. The controller offers additional options such as key lock (simple or 4-digit code), display backlight settings, Celsius/Fahrenheit selection, audible feedback toggle, and limits on the comfort temperature adjustment range for controlled environments. Cleaning is straightforward—power off and wipe with a soft damp cloth; internal dust may be removed with a vacuum from the outside.

Practical installation & specs

Mount using the original rear wall bracket and ensure the supply connection remains accessible after mounting. Models differ in width and weight (from around 4.4 kg to 8.7 kg). Nominal heat outputs are 0.5–2.0 kW depending on model. Standby consumption is minimal (around 0.5 W). The product includes a two-year warranty and should be disposed of through local waste-disposal facilities rather than household refuse.

Notes:

  • Always observe minimum clearances and avoid mounting under a wall socket or where the device can be touched from a bathtub or shower.
  • Presence detection and weekly-program behavior interact (pilot-wire temperature reduction may be ineffective if a weekly program runs).
  • If the overheat protection trips, disconnect power for cooling and correct the cause before restarting.