FPE Maintenance Schedule
Disconnect from mains and let cool. Wipe outside with a soft damp cloth. Do not use scouring powder or furniture polish.
Use a vacuum cleaner to remove dust accumulations from the outside of the unit.
Ask a Question
Do you recommend FPE?
Yes NoFrequently Asked Questions
The FPE series comes in four nominal heat outputs: 0.5 kW, 1.0 kW, 1.5 kW and 2.0 kW, allowing selection according to room size and heating needs.
Is this answer helpful?
In automatic mode the controller senses room occupancy. While a person is detected the comfort temperature remains active; after 30 minutes of absence it lowers by 1°C, after one hour by 2°C and after more than 2 hours it reduces to the Eco temperature (factory 3.5°C reduction).
Is this answer helpful?
The heater includes an overheat protector that cuts power if airflow is blocked, a requirement for professional earthing and fixed wiring, and clear user warnings about covering the unit or operating near flammable substances.
Is this answer helpful?
Yes. The unit supports six programs (P1–P6). P1–P3 are factory-fixed time blocks; P4–P6 are user-configurable with up to three comfort and three Eco periods per program, assigned per weekday.
Is this answer helpful?
Window monitoring is factory-active and pauses heating when a window is open. Central pilot-wire temperature reduction may not function while a weekly program (P1–P6) is executing, so behavior depends on controller mode and schedule.
Is this answer helpful?
Disconnect mains and allow cooling before cleaning. Wipe the exterior with a soft damp cloth; do not use abrasive cleaners or polishes. Remove external dust deposits with a vacuum cleaner; internal work must be done by qualified personnel.
Is this answer helpful?
Yes—the FPE is IP24 splash-protected and can be wall-mounted in bathrooms, provided minimum clearance rules and safe mounting distances (including 1 m in front) are observed and it cannot be touched from a bathtub or shower.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Multiple power options (0.5–2.0 kW) to suit different room sizes.
- Electronic controller with weekly program, presence detection and window monitoring for energy savings.
- IP24 splash protection and slim wall-mounted design for bathrooms and compact spaces.
- Low standby consumption (~0.5 W) and programmable comfort/Eco temperatures.
- Safety features include earth requirement, overheat protection and configurable key lock.
Disadvantages
- Requires qualified electrician for fixed installation and earthing.
- Pilot-wire central temperature reduction can be ineffective when weekly program runs.
- Mounting needs strict clearance (including 1 m in front) which may limit placement options.
- Some features (e.g., temperature limits, code lock setup) require menu navigation and hold-press operations.
- Not suitable for rooms with highly flammable substances; must not be covered.
Product Description
Glen Dimplex FPE Manual — Smart, Efficient Infrared Panel Heaters
Glen Dimplex FPE infrared panel heaters combine simple wall-mounted design with intelligent electronic control for reliable, energy-conscious room heating. Available in four power sizes (0.5, 1.0, 1.5 and 2.0 kW), the FPE series fits a range of rooms and installation needs. Each model is splash-protected (IP24), slim-profiled and supplied with a dedicated wall bracket for secure, horizontal mounting. The units are intended for indoor use only and must be installed on a vertical wall with minimum clearances and a 1 m frontal free zone for safe airflow.
Key features and user experience
The FPE heater is driven by an electronic room temperature controller with a clear display, six control keys and an LED. Modes include manual, automatic and weekly-program operation. Automatic mode adds presence detection (it keeps comfort temperature while the room is occupied and gradually reduces temperature during absence) and window monitoring (pauses heating if a window is open). Manual mode allows selecting comfort, Eco (preset or adjustable offset) and frost-protect temperatures. The weekly program supports six program presets (P1–P6) with P1–P3 fixed and P4–P6 configurable, allowing up to three comfort and three reduced periods per program.
Safety and convenience are central: an overheat protector shuts the unit off if air circulation is blocked; the device must be earthed and connected by a qualified electrician; and children’s usage and cleaning guidance are clearly specified. The controller offers additional options such as key lock (simple or 4-digit code), display backlight settings, Celsius/Fahrenheit selection, audible feedback toggle, and limits on the comfort temperature adjustment range for controlled environments. Cleaning is straightforward—power off and wipe with a soft damp cloth; internal dust may be removed with a vacuum from the outside.
Practical installation & specs
Mount using the original rear wall bracket and ensure the supply connection remains accessible after mounting. Models differ in width and weight (from around 4.4 kg to 8.7 kg). Nominal heat outputs are 0.5–2.0 kW depending on model. Standby consumption is minimal (around 0.5 W). The product includes a two-year warranty and should be disposed of through local waste-disposal facilities rather than household refuse.
Notes:
- Always observe minimum clearances and avoid mounting under a wall socket or where the device can be touched from a bathtub or shower.
- Presence detection and weekly-program behavior interact (pilot-wire temperature reduction may be ineffective if a weekly program runs).
- If the overheat protection trips, disconnect power for cooling and correct the cause before restarting.
Search for 67,732 Manuals online
Type-in Brand or Model