DANGER
Electric shock
Potentially fatal voltages are present in the inverter
during operation. When the inverter is disconnected
from all power sources, this voltage remains in the
inverter for up to 60 seconds.
You should therefore always carry out the following
steps before working on the inverter:
1. Turn the AC/DC disconnector to the OFF posi-
tion.
2. Disconnect the inverter from all AC and DC
voltage sources and make sure that none of the
connections can be accidentally restored.
3. Wait at least 60 seconds for the internal capaci-
tors to discharge.
DANGER
Electric shock
Potentially fatal voltages are present at the inverter's
DC connections. When light falls on the solar mo-
dules, they immediately start to generate electricity.
This also happens when light does not fall directly on
the solar modules.
► Never disconnect the inverter from the solar
modules when it is under load.
► Turn the AC/DC disconnector to the OFF posi-
tion.
► Disconnect the connection to the grid so that the
inverter cannot feed energy into the grid.
► Disconnect the inverter from all AC and DC
voltage sources. Make sure that none of the
connections can be restored accidentally.
► Ensure that the DC cables cannot be touched
accidentally.
● To comply with IEC 62109-5.3.3 safety requirements and avoid
injury or material damage, the inverter must be installed and
operated in accordance with the safety and operating instruc-
tions set out in this manual. Delta Electronics is not respon-
sible for damage resulting from failure to follow the safety and
operating instructions set out in this manual.
● All repair work on the inverter must be carried out by Delta
Electronics. Otherwise the warranty will be void.
● Warning instructions and warning symbols attached to the
inverter by Delta Electronics must not be removed.
● The inverter has a high leakage current value. The grounding
cable must be connected before carrying out commissioning.
● Do not disconnect any cables while the inverter is under load
due to risk of a fault arc.
● To prevent damage due to lightning strikes, follow the provisi-
ons that apply in your country.
● The surface of the inverter can get very hot during operation.
Always wear safety gloves when touching the inverter (except
for the display).
● Only equipment in accordance with SELV (EN 60950) may be
connected to the RS485 interfaces.
● All connections must be sufciently sealed in order to ensure
the IP65 rating. Seal any connections that will not be used with
the covering caps provided.

Chat with your Delta Electronics M6A/M8A/M10A manual using AI

Get instant AI answers from your Delta Electronics M6A/M8A/M10A manual

Ask anything about the Delta Electronics M6A/M8A/M10A. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend M6A/M8A/M10A?

Yes No

Frequently Asked Questions

A

The series includes three models: RPI M6A, RPI M8A, and RPI M10A.

Is this answer helpful?

A

All three models achieve a maximum efficiency of 98.3%.

Is this answer helpful?

A

Yes, it has an IP65 protection rating for dust and water resistance.

Is this answer helpful?

A

It uses natural convection cooling without requiring fans.

Is this answer helpful?

A

The maximum DC input voltage is 1000 volts.

Is this answer helpful?

A

Yes, it works up to 2000 meters above sea level.

Is this answer helpful?

A

Only Delta Electronics authorized personnel can perform warranty repairs.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • High peak efficiency of 98.3% minimizes energy loss during conversion
  • IP65 rating ensures protection against dust and water jets outdoors
  • Natural convection cooling removes need for noisy fans inside unit
  • Wide DC input voltage range supports diverse PV array layouts
  • Multiple communication interfaces including Wi-Fi and RS485 support
VS

Disadvantages

  • Mandatory sixty-second wait time after disconnect poses minor delay
  • Heavy physical weight of 25 to 26 kilograms complicates transport
  • Warranty requires authorized service for repairs maintaining cost
  • Maximum operating altitude limited to 2000 meters above sea level
  • AC connection type restricts some standard connector compatibility
M: QW-35-FL

Product Specification

Note

Prices include partial 0% VAT rates for Austria and Germany

Type

Solar inverter, passive

Input Voltage

200-1000V Direct Current (DC)

MPP Tracker Count

2

Output Phases

3-phase

Interfaces

Wi-Fi (WLAN), 2x RS-485

Protection Rating

IP65

Ambient Temperature

-4°F to +140°F

Dimensions

20.08 x 17.52 x 6.97 in (WxHxD)

M: QW-35-FL

Product Description

Discover the Delta Electronics M6/8/10A Series

Overview of Solar Innovation

The renewable energy sector relies heavily on reliable conversion technology to maximize solar potential globally. Delta Electronics has introduced a robust line of three-phase grid-tied inverters designed specifically for demanding commercial and residential applications worldwide. These units stand out due to their consistently high efficiency ratings and versatile input configurations. Industry professionals often refer to the comprehensive setup details found in the Delta Electronics M6/8/10A Manual when planning large-scale installations. This ensures that all electrical connections meet rigorous safety standards while optimizing total power yield effectively.

Performance Specifications

Each model in the series offers distinct power capabilities to suit varying site requirements accurately. The M6A handles up to 6600 watts of maximum continuous output power steadily. Moving up to the M8A provides 8800 watts efficiently, while the top-tier M10A reaches an impressive 11000 watts reliably. All models share a record peak efficiency of 98.3%, which significantly reduces overall energy losses during the critical conversion process. They operate within an exceptionally wide DC voltage range between 200 and 1000 volts directly. This inherent flexibility allows compatibility with diverse photovoltaic array layouts without major redesigns. Night mode power consumption remains strictly below two watts, ensuring minimal parasitic loss when the sun sets completely.

Design and Connectivity Features

Mechanical design prioritizes extreme durability and ease of routine maintenance procedures. The sturdy enclosure meets strict IP65 standards, protecting sensitive electronics against heavy dust and strong water jets for permanent outdoor mounting environments. Natural convection cooling mechanisms eliminate the need for noisy auxiliary fans inside the chassis. Dimensions remain relatively compact at 510 by 445 by 177 millimeters for space-constrained rooftops. Physical weight ranges from 25 to 26 kilograms depending on the specific unit configuration. Advanced communication interfaces include modern Wi-Fi support alongside legacy RS485 ports for data logging. External power-off functions enhance emergency safety protocols during critical system failures.

Installation Considerations and Safety

Proper handling procedures prevent catastrophic damage to internal capacitors and circuitry. Internal storage capacitors retain dangerous charge levels for approximately sixty seconds after main disconnection occurs. Field technicians must follow strict grounding procedures before any physical operation begins onsite. The warranty policy strictly requires authorized service for repairs to maintain full manufacturer validity long-term. Operating temperature spans from negative twenty-five to positive sixty degrees Celsius continuously. Maximum operational altitude is officially set at 2000 meters above sea level for optimal thermal performance. Careful adherence to these guidelines ensures long-term system reliability and consistent performance stability year over year.

Important Note: Always verify local grid codes before commissioning these inverters to ensure full compliance with regional electricity regulations regarding frequency and voltage tolerance.

M: QW-35-FL