Manual.ly Logo

D.A.S. Action Series Manual

0.0 · 0 Ratings

PDF manual · 26 Pages

English

M: QW-35-FL
page

/ 26

Loading...
e3b635ab20a3e05e439afacf9cc421f6fbd1 page 16
RIGGING
This manual contains needed information for
flying DAS Audio line array systems, description of
the elements and safety precautions. To perform
any operations related to flying the system, read
the present document first, and act on the
warnings and advice given. The goal is to allow the
user to become familiar with the mechanical
elements required to fly the acoustic system, as
well as the safety measures to be taken during
set-up and teardown.
Only experienced installers with adequate
knowledge of the equipment and local safety
regulations should fly speaker boxes. It is the
user's responsibility to ensure that the systems to
be flown (including flying accessories) comply with
state and local regulations.
The working load limits in this manual are the
results of tests by independent laboratories. It is
the user's responsibility to stay within safe limits. It
is the user's responsibility to follow and comply
with safety factors, resistance values, periodical
supervisions and warnings given in this manual.
Product improvement by means of research and
development is on going at DAS. Specifications
are subject to change without notice.
It is common practice to apply 5:1 safety
factors for enclosures and static elements. For
slings and elements exposed to material fatigue
due to friction and load variation the following
ratios must be met; 5:1 for steel cable slings, 4:1
for steel chain slings and 7:1 polyester slings.
Thus, an element with a breaking load limit of
1000 kg may be statically loaded with 200 kg (5:1
safety factor) and dynamically loaded with 142 kg
(7:1 safety factor).
When flying a system, the working load must
be lower than the resistance of each individual
flying point in the enclosure, as well as each box.
Hanging hardware should be regularly inspected
and suspect units replaced if in doubt. This is
important to avoid injury and absolutely no risks
should be taken in this respect. It is highly
recommended that you implement an inspection
and maintenance program on flying elements,
including reports to be filled out by the personnel
that will carry out the inspections. Local
regulations may exist that, in case of accident,
may require you to present evidence of inspection
reports and corrective actions after defects were
found.
Warnings
Absolutely no risks should be taken with
regards to public safety. When flying enclosures
from ceiling support structures, extreme care
should be taken to assure the load bearing
capabilities of the structures so that the installation
is absolutely safe. Do not fly enclosures from
unsafe structures. Consult a certified professional if
needed. All flying accessories that are not supplied
by DAS Audio are the user's responsibility. Use at
your own risk.
Introduction
Flyable action 500 series models feature 6
internal steel angles, with 2 mounting threads
each, so that 12 flying points are available (2 on
each side, 3 on the top panel and 3 on the bottom
panel and 2 on the rear panel). Eyebolt flying
points are factory sealed with M10 screws, which
are replaced with eyebolts on the flying points as
required. Flying with eyebolts is very economical
and safe, and is specially recommended for fixed
installations where the boxes are permanently
fixed.
The illustration shows the internal metal
hardware of an enclosure with eyebolt flying.
22
Manual del Usuario / action 500 series / User’s Manual

Chat with your D.A.S. Action Series manual using AI

Get instant AI answers from your D.A.S. Action Series manual

Ask anything about the D.A.S. Action Series. Answers come from this manual, with the pages they are based on.

Action Series Maintenance Schedule

Regularly
Inspect hanging hardware and replace suspect units

Hanging hardware should be regularly inspected. Replace any suspect units if in doubt to avoid injury.

Show in the manual (page 22)
Regularly
Check wall mount installation thoroughly

The installation should be checked thoroughly at regular intervals, replacing all deteriorated elements to ensure optimum safety.

Show in the manual (page 24)
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend Action Series?

Yes No

Frequently Asked Questions

A

The equipment functions safely between 15 degrees Celsius and 45 degrees Celsius with a relative humidity maximum of 95 percent. Working within these limits prevents overheating and ensures component longevity during operation.

Is this answer helpful?

A

No user serviceable parts exist inside. Servicing must be done by qualified personnel to maintain safety and warranty validity. Unauthorized repairs may void the two year manufacturer warranty.

Is this answer helpful?

A

All products are warranted against manufacturing defects for a period of 24 months from the date of purchase. This covers internal component failures but excludes damage from incorrect use or external factors.

Is this answer helpful?

A

If mains voltage falls below shutdown voltage, the unit stops playing and switches back on automatically when levels are regained. This protects the amplifier from instability caused by low power input.

Is this answer helpful?

A

Yes, provided the safety height limits are respected based on the tripod model and leg spread distance from the central pole. Exceeding height limits can compromise stability during use.

Is this answer helpful?

A

Do not expose this device to rain or moisture. It is IP 20 rated and should not be used near water sources. Outdoor use requires protective covering against environmental exposure.

Is this answer helpful?

A

Each rigging point has a working load limit of 200 kilograms when loaded in the correct plane angle. Safety factors must be applied based on the rigging hardware used for secure overhead installation.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Class D amplifiers provide high efficiency with low heat generation during extended operation.
  • Rugged birch plywood construction ensures durability against transport and environmental wear.
  • Built-in rigging points facilitate safe suspension for fixed installations or touring.
  • DSP presets allow quick adaptation to different performance styles like live or dance.
  • Multiple models available including active subwoofers for complete system coverage.
VS

Disadvantages

  • Fuse replacement requires exact matching of type to prevent electrical hazards.
  • Overheating protection may interrupt performance if ambient conditions are too high.
  • Rigging angle limits reduce working load if suspended beyond forty five degrees.
  • Class A rating may cause radio interference in domestic environments like homes.
  • No user serviceable parts exist inside requiring qualified service for repairs.
M: QW-35-FL

Product Specification

Principle

2-Way

Amplification

active

Impedance

20 Ohms

M: QW-35-FL

Product Description

Discover the Power of the D.A.S. Action Active Unit

When seeking professional audio reinforcement, the D.A.S. Action Active Unit stands out as a versatile solution for performers and sound engineers working in live events and installations. These powered loudspeaker enclosures integrate Class D amplifiers directly into rugged birch plywood cabinets, ensuring reliability and high performance in demanding environments. Whether you need a compact stage monitor or a powerful subwoofer for large venues, the ACTION series offers a comprehensive range of configurations to meet diverse acoustic needs across various industries.

Reading the D.A.S. Action Active Unit Manual is crucial before operating any of these devices to ensure safety and compliance with electrical standards. It outlines vital safety precautions, including environmental limits, electrical connection guidelines, and rigging protocols for suspension. The units are designed to function safely within specific temperature and humidity ranges while protecting users from risks associated with high voltage and improper overhead suspension. Proper installation ensures longevity and optimal sound quality for your audience without technical issues arising during critical performances.

System Versatility and Configuration

The series includes models like the ACTION-508A, ACTION-512A, ACTION-M512A, and ACTION-515A, each tailored for specific roles ranging from compact P.A. systems to dedicated stage monitors. The ACTION-S118A provides deep low-end frequencies with a horn bass design, while the ACTION-S18A offers a direct radiator option for biamped systems. Users can configure line arrays or standard stacks using built-in rigging points rated for specific working loads up to 200 kg per point with proper tensioning. Advanced DSP features allow for preset adjustments like Live, Dance, or Monitor modes, simplifying the mixing process for different musical styles and venue acoustics easily.

Care and Maintenance

Regular maintenance is required to keep these units in top condition for professional use over extended periods. Users must keep grilles clean and avoid blocking air circulation to prevent overheating of the internal amplifier components. If the unit overheats, it protects itself automatically, but investigation into the cause is necessary before reuse to avoid damage. Replacing fuses requires exact matching of type and size to avoid fire hazards, as the equipment is Class A rated. The warranty covers manufacturing defects for 24 months but excludes incorrect use, liquid damage, or unauthorized modifications. Always store manuals with the product for future reference and compliance during resale transactions with new owners.

Safety and Installation Protocols

Safety remains the priority when handling these heavy acoustic systems during transport and setup phases. Only qualified personnel should fly or rig the enclosures using recommended hardware like eyebolts. Do not suspend boxes from handles as this is dangerous and illegal for public safety reasons. Ensure the ground connection is never removed during operation to prevent electric shock risks to operators. Work with the correct mains voltage and use shielded cables to minimize interference from lighting systems nearby. These practices maintain a safe working environment for everyone involved in the event production and installation processes.

Note: Always follow local regulations when rigging equipment or handling electrical connections specific to your region.

M: QW-35-FL

© Copyright 2026 Manual.ly