Manual.ly Logo

DAP Audio M Series Manual

0.0 · 0 Ratings

PDF manual · 12 Pages

English

M: QW-35-FL
page

/ 12

Loading...
8c6e76da60c661bcb5375adc08ca68078842 page 4
3
M10 – M12 – M15
Ordercode: D3660 – D3661 – D3662
Do not drive the inputs with a signal level bigger, than required to drive the equipment to full output.
Do not open this device. Risk: hazardous radiation exposure.
Do not switch the system on and off in short intervals, as this would reduce the system’s life.
Extreme frequency boosts in connection with a high input signal level may lead to overdriving your
equipment. Should this occur, it is necessary to reduce the input signal level by using the INPUT
control.
For replacement use fuses of same type and rating only.
If device is dropped or struck, disconnect mains power supply immediately. Have a qualified
engineer inspect for safety before operating.
If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not
switch it on immediately. The arising condensation water might damage your system. Leave the
system switched off until it has reached room temperature.
Keep this user’s manual for future consultation. Also remember that the crossover will get a better
price on the secondhand market if (as well as being in good condition) it has its original
documentation and packaging.
Make sure that the available voltage is not higher than stated on the rear panel.
Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time.
Make sure that the signals into the mixer are balanced, otherwise hum could be created.
Make sure that there is sufficient room on all sides of the system for air circulation.
Make sure you don’t use the wrong kind of cables or defective cables.
Make sure you use DI boxes to balance unbalanced signals; All incoming signals should be clear
Never let the power-cord come into contact with other cables! Handle the power-cord and all
connections with the mains with particular caution!
Never remove warning or informative labels from the unit.
Never use anything to cover the ground contact.
Only use device indoor, avoid contact with water or other liquids.
Please turn off the power switch, when changing the power cord or signal cable, or select the input
mode switch.
Prevent distortion! Make sure that all components connected to the M10/M12/M15 active monitor
have sufficient power ratings. Otherwise distortion will be generated because the components are
operated at their limits.
Repairs, servicing and electric connection must be carried out by a qualified technician.
Sometimes, when you want to send one signal to more than one amplifier, you should use a signal
distributor.
The best way (even if not always feasible) to avoid ground loops is to connect the electric ground of
all the equipment to a single central point (“star” system). In this case, the central point can be the
mixer.
To avoid or solve hum and buzzing troubles, try different combinations of lifting grounds on units that
are supplied with ground lift switches or make sure all chassis are connected to earth ground, either
through the A.C. power cord ground or by the front panel rack mount screws.
To emphasize a frequency range, you don’t necessarily have to move its respective sliding control
upward; try lowering surrounding frequency ranges instead. This way, you avoid causing the next
piece of equipment in your sound path to overdrive. You also preserve valuable dynamic reserve
(“headroom”)
WARRANTY: Till one year after date of purchase.
When connecting the other parts of your sound system, watch out for the so-called “ground loops”.
Disposing of this product should not be placed in municipal waste and should be
separate collection.

Chat with your DAP Audio M Series manual using AI

Get instant AI answers from your DAP Audio M Series manual

Ask anything about the DAP Audio M Series. Answers come from this manual, with the pages they are based on.

M Series Maintenance Schedule

Periodically
Check cables

Periodically check your cables for faults, ground hum, or discharges to ensure reliability.

As needed
Inspect power cord and device

Check the device and power cord from time to time to ensure they are not crimped or damaged.

M: QW-35-FL

Ask a Question

0/1000

Do you recommend M Series?

Yes No

Frequently Asked Questions

A

The system utilizes an Active Bi-Amp configuration with Class D power supply. Output is 335W LF and 65W HF. Power supply accepts AC 100V to 240V ensuring global compatibility for touring.

Is this answer helpful?

A

No, these units are designed for indoor use only. You must avoid contact with water or other liquids to maintain safety and functionality.

Is this answer helpful?

A

Use XLR or Jack Combo connectors for balanced or unbalanced signals. Ensure you use high quality cables to avoid ground hum or faulty contacts.

Is this answer helpful?

A

The warranty covers the product for one year after the date of purchase. Ensure you keep packaging and documentation for secondhand value.

Is this answer helpful?

A

Yes, the housing includes an integrated 35mm Pole Socket for vertical mounting in addition to standard floor placement.

Is this answer helpful?

A

You must request an RMA number prior to shipping. Returns without an RMA number will be refused. Include original packing materials always.

Is this answer helpful?

A

Yes, the system includes thermal overload protection and signal limiter indication LED to prevent distortion and component damage.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Compact and versatile wedge design for stage monitoring
  • Active Bi-Amp Class D power supply for efficiency
  • Wide frequency response capturing deep lows to crisp highs
  • Ground lift switch helps prevent electrical hum issues
  • Multiple models available to suit different venue sizes
VS

Disadvantages

  • Designed for indoor use only not suitable for outside
  • No user serviceable parts requiring qualified technicians
  • Heavier models increase transport difficulty significantly
  • Original packaging required for authorized return procedures
  • Potential ground loops if not connected correctly to ground
M: QW-35-FL

Product Specification

Principle

2-Way

Tweeter

1x 1\"

Amplification

Active

Power

415W RMS

Dispersion Angle

70°x70°

M: QW-35-FL

Product Description

Discover the Power of DAP Audio M

Welcome to professional audio monitoring where precision meets reliability. The DAP Audio M series stands out as a premier choice for musicians and engineers seeking accurate sound projection. Each model is crafted to deliver exceptional performance ensuring clarity. Whether on stage or managing front of house, these active monitors provide tools for a pristine sound experience.

Models Designed for Versatility

The series includes three distinct models tailored to various volume needs. The M10 offers a compact solution for smaller stages. The M12 provides a step up in low-frequency response ideal for mid-size venues. The M15 delivers power for larger performances with enhanced bass capabilities. All models share a wedge design that decreases resonance ensuring the cabinet does not interfere with sound quality. This ergonomic placement allows performers to hear themselves clearly while staying on top of their performance during critical moments.

Technical Superiority and Features

At the heart of these monitors lies a sophisticated System active Bi-Amp configuration. The Class D power supply ensures efficient energy use while delivering robust output. Power outputs range up to 335W LF and 65W HF handling dynamic swings without distressing components. Frequency response spans widely capturing sounds from deep lows at 60Hz to crisp highs at 20kHz. A preset switch allows quick adjustments between Monitor and FOH modes streamlining workflow during live events. Electronic protection guards against thermal overload or signal clipping adding peace of mind during high-intensity operations.

Safety and Maintenance

Operating these devices requires attention to detail to maintain peak performance. The user manual for this DAP Audio M piece Manual guidelines highlights critical steps for safe installation. Proper grounding is essential to avoid ground loops and potential hum issues. Users must ensure sufficient airflow around the unit to prevent overheating. The robust 15mm MDF housing with scratch-resistant paint ensures durability through transport and regular use. For replacements the original packaging is recommended to protect the investment during storage or shipping. Adhering to proper safety instructions guarantees longevity and prevents any damage to the equipment or surrounding environment. By following the provided guidelines you secure a reliable foundation for your audio setup needs. Keeping the manual handy ensures you have access to troubleshooting tips whenever needed during your long career. Always disconnect power from the mains when system is not used. Connectivity options are diverse featuring XLR and Jack Combo connectors for balanced or unbalanced signals. This flexibility makes interfacing with mixers and other professional gear straightforward. Physical dimensions vary slightly with weights ranging from 11kg to 18kg depending on the size.