5. TROUBLESHOOTING
ELECTRODE FAULT
The device emits a tone and alternately displays the pair of electrodes symbol and an arrow pointing towards
the channel on which a problem has been detected. In the above example, the stimulator has detected an
error on channel 1.
Check that the electrodes are connected to this channel.
If electrodes are old, worn and/or if the contact is poor: try using new electrodes.
Try using the stimulation cable on a different channel. If the cable is still faulty, replace it
(www.compexstore.com).
STIMULATION DOES NOT PRODUCE THE USUAL SENSATION
Check that all settings are correct and check electrodes are properly positioned.
Change the position of the electrodes slightly.
STIMULATION CAUSES DISCOMFORT
Electrodes lose their adhesive capacity and no longer provide suitable contact with skin.
Electrodes are worn and must be replaced.
Change the position of the electrodes slightly.

Chat with your Compex SP 4.0 manual using AI

Get instant AI answers from your Compex SP 4.0 manual

Ask anything about the Compex SP 4.0. Answers come from this manual, with the pages they are based on.

SP 4.0 Maintenance Schedule

As needed
Clean the device

Clean with a soft cloth and solvent-free alcohol-based detergent using minimal liquid. Do not disassemble.

Show in the manual (page 19)
When worn
Replace electrodes

Replace if old, worn, or losing adhesive capacity to ensure proper skin contact.

Show in the manual (page 17)
When faulty
Replace stimulation cable

Replace the cable if it remains faulty after testing on a different channel.

Show in the manual (page 17)
When faulty
Replace battery

Replace the battery if it fails recovery cycles or displays a fault screen indicating failure.

Show in the manual (page 19)
M: QW-35-FL

Ask a Question

0/1000

Do you recommend SP 4.0?

Yes No

Frequently Asked Questions

A

It is used for electrostimulation sessions that support muscle activation, recovery, and certain pain-relief applications. The device can be adapted to different goals depending on the selected program and intensity level.

Is this answer helpful?

A

Yes, it includes MI-scan. This feature tests the chosen muscle group and helps adjust stimulation to your body’s response. However, not all MI functions are available on this model.

Is this answer helpful?

A

The SP 4.0 has four independent stimulation channels. Each channel can be adjusted separately, which helps you work on multiple muscle areas in one session.

Is this answer helpful?

A

Choose a category, select a program, then raise the stimulation intensity until the session begins. It is best to start with lower levels and increase gradually for comfort and control.

Is this answer helpful?

A

Check that the electrodes are correctly placed, the settings are right, and the pads are in good condition. If needed, slightly reposition the electrodes or replace worn ones.

Is this answer helpful?

A

Fully charge the battery before first use, use the original Compex charger, and keep the battery charged during long storage periods. If the device will not be used for months, follow the storage guidance carefully.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Four independent channels allow flexible, personalized stimulation.
  • MI-scan helps adapt settings to your muscle response automatically.
  • Easy-to-use controls and quick access to recent programs.
  • Rechargeable design with clear battery and charging guidance.
VS

Disadvantages

  • Not every MI feature is available on this model.
  • Electrode wear can affect comfort and performance over time.
  • Pain-relief programs should not be used long-term without medical advice.
  • Requires proper electrode placement and correct settings for best results.
M: OA-GPT-54-NAN

Product Specification

Type

Electrical stimulation device

Colors

black, gray, yellow

M: OA-GPT-54-NAN

Product Description

Compex SP 4.0 Electrostimulation Device

The Compex SP 4.0 is built for users who want a practical, performance-focused way to train muscles, support recovery, and manage localized discomfort. Using four independent stimulation channels, it delivers adjustable electrical impulses through electrodes to activate muscle fibers or target sensory nerves. The result is a flexible system that can fit workout routines, rehab-inspired sessions, or post-exercise recovery.

What makes the SP 4.0 stand out is its emphasis on control and precision. The device allows you to fine-tune intensity on each channel separately, or boost several channels together with the I-button for a smoother setup. It also stores the last five programs used, making repeat sessions faster and easier to manage. For first-time users, the menu offers language, contrast, sound, and backlight settings, helping the interface feel more comfortable from the start.

The SP 4.0 includes MI-scan technology, which can automatically test the selected muscle group and adapt the stimulation settings to your body’s response. That means less guesswork and a more personalized start to each session. While the device does not include every MI feature found on other Compex models, its MI-scan function still adds a smart layer of convenience for those who want guided stimulation.

This stimulator is also designed with everyday usability in mind. It uses a rechargeable NiMH battery, provides a clear battery indicator, and supports structured training cycles so you can progress gradually over time. The manual recommends starting with the first cycle and increasing intensity before moving to the next stage, which makes the SP 4.0 feel methodical rather than overwhelming.

Maintenance is straightforward: keep it dry, clean it gently with a soft cloth, and use only approved accessories. The device is intended for home use, yet it still follows strict medical and electromagnetic compatibility standards. For best results, pair sessions with regular exercise, good nutrition, and balanced recovery habits.

Notes

  • Use only recommended Compex cables, electrodes, charger, and battery.
  • Recharge the battery fully before first use.
  • Avoid prolonged pain-relief use without medical advice.
  • Check electrode placement if stimulation feels weak or uncomfortable.