Setting Up an Optional Management Connection
You can optionally set up an out-of-band management connection for monitoring and troubleshooting purposes.
To do this, you connect either the RJ-45 management port or the SFP management port on the switch to an
external hub, switch, or router.
Before you begin
To prevent an IP address conflict, you must complete the initial configuration for the switch and establish an
IP address before you create the management connection.
Step 1 Connect the appropriate modular interface cable to only one of the two management ports on the switch.Connect the
management interface cable to a management port on the leaf switch. If the switch has two management ports, use the
optical port if you have an optical interface cable or use the RJ-45 port if you have a copper interface cable.
• For the RJ-45 management port, use a copper interface cable with RJ-45 connectors (can be used for shorter
connections).
• For the SFP management port, use an optical interface cable with LH or SX SFP transceivers (can be used for longer
connections).
If you use the management interface, connect only one of the two management ports. The switch does not
support your use of two management ports at the same time.
Note
Step 2 Connect the other end of the cable to an external hub, switch, or router.
Maintaining Transceivers and Optical Cables
Transceivers and fiber-optic cables must be kept clean and dust free to maintain high signal accuracy and
prevent damage to the connectors. Attenuation (loss of light) is increased by contamination and should be
below 0.35 dB.
Consider the following maintenance guidelines:
• Transceivers are static sensitive. To prevent ESD damage, wear an ESD-preventative wrist strap that is
connected to the grounded chassis.
• Do not remove and insert a transceiver more often than is necessary. Repeated removals and insertions
can shorten its useful life.
• Keep all optical connections covered when not in use. Clean them before using to prevent dust from
scratching the fiber-optic cable ends.
• Do not touch the ends of connectors. Touching the ends can leave fingerprints and cause other
contamination.
• Clean the connectors regularly; the required frequency of cleaning depends upon the environment. In
addition, clean connectors if they are exposed to dust or accidentally touched. Both wet and dry cleaning
techniques can be effective; refer to your site's fiber-optic connection cleaning procedures.
Cisco Nexus 9336C-FX2 ACI-Mode Switch Hardware Installation Guide
30
Connecting the Switch to the ACI Fabric
Setting Up an Optional Management Connection

Chat with your Cisco Nexus 9336C-FX2 manual using AI

Get instant AI answers from your Cisco Nexus 9336C-FX2 manual

Ask anything about the Cisco Nexus 9336C-FX2. Answers come from this manual, with the pages they are based on.

Nexus 9336C-FX2 Maintenance Schedule

Regularly
Clean transceiver connectors

Clean connectors regularly depending on the environment. Clean if exposed to dust or accidentally touched.

Show in the manual (page 38)
Regularly
Inspect fiber ends for dust and damage

Inspect routinely for dust and damage. If damage is suspected, clean and inspect under a microscope.

Show in the manual (page 38)
M: QW-35-FL

Ask a Question

0/1000

Do you recommend Nexus 9336C-FX2?

Yes No

Frequently Asked Questions

A

The switch supports 100G and 40G natively on QSFP28 ports, and can run 10G using QSFP-to-SFP adapters. Many ports also support breakout configurations to enable mixed 10/40/100G deployments depending on transceiver and cable choices.

Is this answer helpful?

A

Yes. The platform provides hardware MACsec encryption at line rate to secure link-level traffic, reducing the need for higher-layer encryption for east-west data center traffic and helping meet regulatory or tenant isolation requirements.

Is this answer helpful?

A

You can replace a single fan or a single power supply while the switch remains operational, provided redundancy is maintained and replacement modules match the airflow direction. Replacing multiple modules or changing airflow direction requires shutdown.

Is this answer helpful?

A

Ensure operating temperature 0–40°C, 5–95% non-condensing humidity, proper altitude considerations, clean airflow free of dust, correct rack clearance, and dedicated power circuits. Grounding and EMI/RFI mitigation are essential for reliability and safety.

Is this answer helpful?

A

The switch supports Cisco-approved QSFP28 transceivers (LR, SR, AOC/DAC variants) and SFP+ via adapters. Refer to Cisco transceiver compatibility documentation for exact supported modules and distance limits.

Is this answer helpful?

A

The chassis uses two power supplies in 1+1 redundancy with current sharing. For full power redundancy across failures, connect each supply to separate power sources per site electrical guidelines; do not mix AC and DC in the same chassis.

Is this answer helpful?

A

Use ESD wrist straps, avoid frequent insertions/removals, keep connectors covered and clean, inspect under a microscope if contamination is suspected, and maintain attenuation below recommended levels. Follow wet or dry cleaning procedures per site standards.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High density: 36 QSFP28 ports supporting 40/100G with breakout for mixed-speed deployments.
  • MACsec hardware support for line-rate link encryption and improved east-west traffic security.
  • Hot-swappable, redundant 1100W power supplies and serviceable fan modules for in-service maintenance.
  • Flexible management: RJ-45 and SFP OOB management ports plus console access for initial setup.
  • ACI and NX-OS compatibility with detailed fabric topology guidance for scalable leaf-spine designs.
VS

Disadvantages

  • Requires careful airflow planning—all fan and power modules must share same airflow direction.
  • High power and cooling demands; provisioning up to peak input increases infrastructure requirements.
  • Transceiver and cable cleanliness/ESD handling impose strict maintenance procedures.
  • Mixing AC and DC power supplies is prohibited; redundant sources must follow specific wiring rules.
  • Large deployments require careful rack grounding and site preparation to avoid EMI/RFI issues.
M: OA-GPT-5-NAN

Product Specification

Function

Switch, SAN switch

Type

Standalone, Rackmount (via mounting brackets)

Network ports

36x QSFP28

Speeds

36x QSFP28 (1G/10G/25G/40G/100Gb/s)

PoE

N/A

Backplane

7.2Tb/s, 2.8Gp/s, 40MB packet buffer, 256k Mac addresses

Officially supported standards

802.1AX, 802.1D, 802.1Q, 802.1AE, 802.1p, 802.3ab, 802.3ae, IGMP

Configuration

Web interface, console, serial (RJ-45, USB-A 2.0, rear), network (SFP+, RJ-45, dedicated, 10/100/1000Base-T, rear)

Cooling

active, 3x fans (1.57in, 1x hot-plug each)

Dimensions (WxHxD)

17.28x1.73x24.53in, 1U

Weight

18.74lb

Color

silver

Features

Metal housing, removable mounting brackets, firmware updates possible, redundant power supply (redundant power input), 2x hot-plug power supply

Manufacturer warranty

one year

Note

For this device, "link aggregation" was officially specified with the obsolete standard IEEE802.3ad. Since 2008, the function has no longer been managed by the IEEE "Working Group 3" (IEEE 802.3, CSMA/CD - Ethernet), but by "Working Group 1" (IEEE 802.1, High Level Interface - Internetworking) and technically defined unchanged via IEEE 802.1AX.

M: OA-GPT-54-NAN

Product Description

Cisco Nexus 9300-FX2 MACsec Rackmount 100G Managed Switch, 36x QSFP28 Manual

The Cisco Nexus 9300-FX2 MACsec rackmount switch is a high-performance, data-center-grade 1U switch built for modern spine-leaf architectures. With 36 QSFP28 ports capable of 40/100G operation and MACsec hardware support, this platform addresses demanding throughput, low-latency forwarding, and strong encryption requirements for east-west traffic. Designed for ACI fabrics or standalone NX-OS deployments, the Nexus 9300-FX2 balances dense uplink capacity, flexible breakout options, and field-replaceable modularity to simplify operations and maintenance.

This switch supports flexible port modes: full QSFP28 100G, 40G operation, and 10G via adapters, enabling mixed-speed environments without sacrificing port density. Redundant, hot-swappable 1100W power supplies and three serviceable fan modules offer 1+1 power redundancy and configurable front- or rear-airflow options to integrate with hot-aisle/cold-aisle data center designs. Advanced management comes through out-of-band RJ-45 or SFP management ports and a console interface for initial setup.

Security and compliance are central: MACsec capability at line rate secures link-level traffic between devices, while the platform adheres to industry safety and EMC standards. The chassis provides diagnostic LEDs, lane-level link indicators, and clear guidance for site planning—temperature, humidity, airflow, grounding, and cabling best practices—helping ensure reliable deployment in enterprise and cloud environments.

Operational simplicity is supported by field-replaceable fan and power modules, clear installation procedures for rack mounting and grounding, and guidance for transceiver handling and fiber maintenance. The manual details ACI fabric topologies, recommended leaf-to-spine connections, and transceiver compatibility, helping network architects plan capacity, redundancy, and performance at scale.

For data center teams seeking a secure, high-density 100G-capable leaf or spine switch with enterprise-grade operational features, the Cisco Nexus 9300-FX2 offers a practical combination of throughput, port flexibility, and maintainability. Its robust site-prep and safety guidance, plus modular hardware design, make it suitable for environments requiring predictable uptime and extensive cabling and cooling considerations.

Notes

  • Supports 36 QSFP28 ports with flexible breakout and adapter options for 10G/40G/100G.
  • Hardware MACsec provides link-layer encryption for sensitive east-west traffic.
  • Field-replaceable fans and power supplies require consistent airflow direction and grounding practices.
  • Complies with standard safety and EMC certifications; follow site-prep guidance for best results.