C-1
Cisco MDS 9020 Fabric Switch Hardware Installation Guide
OL-6987-01
APPENDIX
C
Technical Specifications
This appendix includes the following technical specifications for the Cisco MDS 9020 Fabric Switch:
• Switch Specifications, page C-1
• Power Specifications, page C-2
• Supported Power Cords and Plugs, page C-3
Switch Specifications
Table C-1 lists the environmental specifications for the Cisco MDS 9020 Fabric Switch. Table C-2 lists
the switch specifications for the Cisco MDS 9020 Fabric Switch.
Table C-1 Environmental Specifications for the Cisco MDS 9020 Fabric Switch
Description Specification
Temperature, ambient operating 41 to 104°F (5 to 40°C)
Temperature, ambient nonoperating and storage - 40 to 158°F (- 40 to 70°C)
Humidity (RH), ambient (noncondensing)
operating
5 to 90%
Humidity (RH), ambient (noncondensing)
nonoperating and storage
5 to 93%
Altitude, operating 0 to 10,000 ft (0 to 2000 m)
Table C-2 Cisco MDS 9020 Fabric Switch Specifications
Description Specification
Dimensions Width = 17 in. (43.2 cm)
Height = 1.70 in. (4.32 cm)
Depth = 12.0 in. (30.5 cm)
Rack unit (RU) Chassis requires 1 RU (1.75 in. or 4.45 cm)
Weight 9 lb
Airflow Front-to-back

Chat with your Cisco CAB-C15-CBN= manual using AI

Get instant AI answers from your Cisco CAB-C15-CBN= manual

Ask anything about the Cisco CAB-C15-CBN=. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend CAB-C15-CBN=?

Yes No

Frequently Asked Questions

A

It is used to supply power to supported Cisco equipment, including the Cisco MDS 9020 Fabric Switch. It is designed for environments where a Cisco-approved IEC C15 connection is required.

Is this answer helpful?

A

The standard cord uses an IEC C15 connector on the switch side. The optional jumper version uses IEC C15 on the switch side and IEC C14 on the PDU side.

Is this answer helpful?

A

Yes. The jumper version is especially useful in cabinets and rack systems that connect to a power distribution unit with IEC C13 outlets.

Is this answer helpful?

A

The switch supports 100 to 240 VAC at 50 to 60 Hz. The jumper power cord is rated 250 VAC, 13A with C14-C15 connectors.

Is this answer helpful?

A

Cisco notes that only the standard or jumper power cords provided with the switch are supported, so third-party alternatives are not recommended.

Is this answer helpful?

A

Grounding helps protect equipment and supports safe operation. The receptacle and service equipment should be properly grounded according to local codes.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Cisco-specific design helps ensure compatibility with supported hardware.
  • IEC C15 switch-end connector matches the required inlet type.
  • Optional jumper version works well with PDU-based rack installations.
  • Grounding and voltage support align with enterprise power standards.
VS

Disadvantages

  • Only approved Cisco cords are supported, limiting flexibility.
  • Connector and outlet types must match exactly to avoid setup issues.
  • Not ideal for generic or nonstandard power environments.
  • Installation still depends on proper circuit ratings and grounding.
M: OA-GPT-54-NAN

Product Specification

Connections

1x C15, 1x C14

M: OA-GPT-54-NAN

Product Description

Cisco CAB-C15-CBN= Power Cord: A Practical Fit for Cisco Infrastructure

The Cisco CAB-C15-CBN= power cord is a purpose-built accessory designed for reliable connectivity in Cisco environments. If you’re setting up a Cisco MDS 9020 Fabric Switch or looking for a Cisco CAB-C15-CBN= Power cord Manual-style overview, this product stands out for one key reason: it is built to match the electrical and connector requirements of supported Cisco hardware.

Why it matters

In data center and rack-mounted deployments, power compatibility is not a small detail—it is the foundation of stable operation. The CAB-C15-CBN= uses an IEC C15 connector on the switch side, making it suitable for Cisco equipment that requires that specific inlet type. For cabinet-based setups, the optional jumper version adds an IEC C14 connection for use with a power distribution unit that provides IEC C13 outlets.

Built for controlled, dependable power delivery

Cisco’s documentation emphasizes proper circuit sizing, grounding, and adherence to local electrical codes. That makes sense for equipment that may run continuously in mission-critical environments. The switch itself is compact, rack-friendly, and engineered for front-to-back airflow, which helps it integrate cleanly into standard rack layouts.

The power specifications are equally straightforward: the system accepts 100 to 240 VAC at 50 to 60 Hz, with output rails of 3, 5, and 12 VDC. The supported cord family is tightly defined, so there is less guesswork when selecting accessories. In practice, that means fewer compatibility issues and a more predictable installation experience.

Best use cases

This power cord is a strong match for Cisco storage and switching environments where standardized components are preferred. It is especially useful in rack cabinets, enterprise closets, and deployments that rely on Cisco-approved power accessories. When matched correctly, it helps support uninterrupted operation while keeping the setup neat and compliant.

Notes

  • Only Cisco-supported power cords and jumper cords should be used.
  • Make sure the outlet type and plug style match your site configuration.
  • Verify circuit capacity before powering the switch.