Natural Feeling Maintenance Schedule
Wash the anatomical cup (2) after each use to eliminate any milk residue.
Lubricate the piston ring with baby oil when the handle movement becomes difficult to prevent wear.
Ask a Question
Do you recommend Natural Feeling?
Yes NoFrequently Asked Questions
All milk-contact components except the handle can be sterilised: cold sterilising solutions, steam sterilisers or boiling are acceptable. The handle should only be cleaned with a damp cloth; immersing or sterilising the handle can damage its function.
Is this answer helpful?
Start with the flow-regulation valve at its minimum setting and pump gently. Gradually increase suction until you reach a comfortable level. If suction causes discomfort, reduce it. Rhythmic, gentle pressure on the handle helps you control extraction speed and comfort.
Is this answer helpful?
The handle should be wiped with a damp cloth only. If the handle becomes stiff or doesn’t move smoothly, push to expose the piston ring and apply a small amount of baby oil or similar to the ring. Avoid immersing or sterilising the handle.
Is this answer helpful?
Always ensure the anti-backflow (one-way) valve is inserted fully and correctly into its seat in the anatomical cup. Proper seating of this valve is critical to prevent milk entering the handle and to maintain hygiene.
Is this answer helpful?
Yes. The pump includes a Step Up 1 150 mL bottle, ring and teat. After pumping, attach the included ring and teat to the bottle to create a ready-to-use feeding bottle without transferring milk between containers.
Is this answer helpful?
Before first use, disassemble and thoroughly wash and sanitise all milk-contact parts (except the handle) following the cleaning and sanitising instructions. Check all components are intact and correctly assembled before pumping.
Is this answer helpful?
Keep the pump and accessories, including packaging elements like plastic bags and boxes, out of children’s reach, as these can be hazardous. Inspect the device and components for damage before each use; do not use if damaged.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Ergonomic manual handle gives precise, rhythmic control over suction without batteries.
- Soft silicone cushion and anatomical cup enhance comfort and fit during pumping.
- Includes Step Up 1 150 mL bottle and teat so pumped milk can be fed immediately.
- One-way anti-backflow valve prevents milk from entering the handle for better hygiene.
- Simple disassembly and sterilisation-compatible parts (except handle) for easy cleaning.
Disadvantages
- Manual operation may be tiring for extended pumping compared with electric pumps.
- Handle must not be immersed or steam-sterilised; only wiped clean, which limits full sanitisation of that part.
- Requires occasional lubrication of the piston ring to maintain smooth operation.
- Smaller 150 mL bottle may require transfers for higher-volume sessions.
- Proper valve seating is essential—misplacement can impair suction and performance.
Product Specification
Accessories
1x Well-being Baby bottle 5.07 fl oz
Product Description
Chicco Natural Feeling Handmilchpumpe Manual
The Chicco Natural Feeling hand breast pump is a compact, manually operated pump designed for comfortable, on-the-go milk expression. Built around an anatomical cup with a soft silicone membrane and an ergonomic handle, the pump aims to combine gentle suction control with easy assembly and cleaning. The package includes a Step Up 1 150 mL bottle and teat, adapters for alternate bottle systems, a flow-regulation valve, a one-way anti-backflow valve, cap and base—making it simple to pump, store, and feed without transferring milk between containers.
Design and Components
The pump’s anatomical cup features a removable soft silicone cushion for comfort and an anatomically shaped funnel to ensure a snug fit on the breast. The ergonomic handle offers rhythmic manual control of suction, while the flow regulation valve lets users fine-tune intensity from minimum to maximum. A one-way valve prevents milk backflow into the handle and mechanism, safeguarding hygiene. The Step Up connector and additional adapter options provide immediate conversion from pump to feeding bottle with the included teat.
Cleaning, Maintenance and Use
All milk-contact parts (except the handle) should be cleaned and sanitised before first use and after each session. Components can be cold-sterilised, steam-sterilised, or boiled where indicated. The handle should only be wiped with a damp cloth; immersion or sterilisation of the handle is discouraged because it can impair function. Periodic maintenance includes lightly oiling the piston ring with baby oil if the handle movement becomes stiff. Assembly and disassembly are straightforward: insert the one-way valve fully, fit the piston pin and washer into the handle seat, click the handle into place, screw on the connector and bottle, and apply the silicone cushion for comfort.
Practical Tips
Before pumping, wash hands and optionally cleanse the breast (or use Chicco Natural Feeling wipes). Gentle concentric massage toward the areola can stimulate let-down. Start at the lowest suction setting and increase gradually until comfortable; reduce suction if it becomes uncomfortable. Alternate pumping between breasts until they feel empty. To feed immediately, attach the included ring and teat to the bottle for a ready-to-use Step Up 1 feeding bottle.
Safety and Warnings
Keep all parts and packaging out of children’s reach. Inspect components before each use; do not use if damaged. Use the product only for its intended purpose (breast pump/feeding bottle). Follow cleaning, sanitising and maintenance instructions carefully to ensure correct operation.
Notes
- The handle never contacts milk; clean it with a damp cloth only. Excessive moisture or sterilisation of the handle can damage function.
- Ensure the one-way valve is properly seated for reliable suction and hygiene.
- Lubricate the piston ring sparingly with baby oil if handle action becomes stiff.