2. USE
This instrument is a digital tester. It measures AC and DC
voltages, alternating currents, resistances, and capacitances.
It also has a continuity function and a diode function and can
be used for non contact voltage detection.
2.1. INSTRUMENT TEST
Before making any measurements, test all of the functions
of the instrument.
To switch the instrument on, turn the switch to any position.
All segments of the display unit light (Figure 6) and the
instrument emits a continuous beep.
If the battery voltage is too low for correct operation of the
instrument, the symbol is displayed.
If the battery voltage is much too low, the display unit
will not light.
In both cases, it is time to replace the batteries (see § 4.2).
With the inputs disconnected, set the switch to W. The
display unit indicates - - - -.
Connect the red probe tip to the + terminal and the black
probe tip to the COM terminal. Bring the two probe tips
together, so that they touch. The instrument indicates a
resistance near zero and emits a continuous beep.
Set the switch to V and measure a known voltage.
If the results of these four tests are correct, your instrument
is ready for use.
2.2. VOLTAGE
Connect the red probe tip to the + terminal and the black
probe tip to the COM terminal.
Set the switch to V.
Keep your hands behind the guards of the device and of
the test probe (Figure 9).
Place the test probes on the element to be tested and
maintain a rm contact.
The voltage is displayed (Figure 7).
If the voltage is > 30V, the instrument displays , indicating
that the voltage is dangerous.
As default, the instrument is in automatic mode (
SCAN
). If the
voltage is AC, the instrument displays AC. If the voltage is
DC, it indicates DC and displays its polarity.
The Select key is used to exit from the automatic mode (the
SCAN
symbol disappears) and display the AC voltage only, or
the DC voltage only, or to return to the automatic mode.
To determine the type of voltage (AC or DC) for a measure-
ment < 1V, exit from the automatic mode.
Do not use the C.A 757 to check for the absence of a
voltage. For that, use a VAT.

Chat with your Chauvin Arnoux CA 757 manual using AI

Get instant AI answers from your Chauvin Arnoux CA 757 manual

Ask anything about the Chauvin Arnoux CA 757. Answers come from this manual, with the pages they are based on.

CA 757 Maintenance Schedule

Before each use
Inspect leads, housing, and accessories

Check insulation condition before use. Set aside any item with deteriorated insulation for repair or scrapping.

Show in the manual (page 16)
Before each measurement
Test all instrument functions

Verify display, disconnected-input indication, probe continuity, and a known voltage before measuring.

Show in the manual (page 20)
M: gpt-5.6-terra

Ask a Question

0/1000

Do you recommend CA 757?

Yes No

Frequently Asked Questions

A

The CA 757 measures AC and DC voltages, alternating current using the MiniFlex sensor, resistance, continuity, diode drops, and capacitance. It also features non-contact voltage (NCV) detection and has a continuity buzzer and backlit display.

Is this answer helpful?

A

Yes. It is rated 600 V CAT III and complies with IEC 61010 standards for the instrument, leads, and current sensor. Users must follow safety precautions, keep fingers behind guards, and not exceed the specified voltage or category limits.

Is this answer helpful?

A

NCV detects approximate presence of AC line voltage (around 230 V) up to ~5 cm and provides four graded audible/visual alerts. It is a detection aid only; absence of NCV indication does not guarantee no voltage—use a certified voltage absence tester to confirm.

Is this answer helpful?

A

The tester ships with removable probe tips, a MiniFlex flexible current sensor (MA101-250), two AAA batteries, a carrying pouch, Velcro straps, and a test certificate. Spare probes, sensors, and adapters are available from the manufacturer or authorized distributors.

Is this answer helpful?

A

Certain large ranges—such as the 30 MΩ resistance range and the 3 mF/30 mF capacitance ranges—are not accessible in automatic (SCAN) mode and must be selected manually via the rotary switch or Select key.

Is this answer helpful?

A

Powered by two 1.5 V alkaline AAA (LR3) cells, typical autonomy is around 100 hours. Replace batteries when the low-battery symbol appears; unscrew the battery compartment cap, insert new batteries, and secure the cap fully.

Is this answer helpful?

A

Operating range is -10 °C to 55 °C (≤80% RH), storage -20 °C to +55 °C. It offers IP54 protection, IK04 impact rating, and 2 m drop resistance; altitude limit is below 2000 m and pollution degree 2.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • Comprehensive measurement set: AC/DC voltage, resistance, continuity, diode, capacitance, current via MiniFlex, and NCV.
  • Certified safety: 600 V CAT III rating and compliance with IEC 61010 series for leads and sensor.
  • Field-ready build: IP54 protection, 2 m drop test, backlit LCD, probe storage and compact form factor.
  • Flexible current sensing: MiniFlex sensor enables up to 300 A range with easy single-conductor clamping.
  • Energy-conscious features: automatic standby to preserve battery life and long battery autonomy (~100 h).
VS

Disadvantages

  • Some high-range capacitance and resistance modes (3 mF, 30 mF, 30 MΩ) are not available in auto mode and require manual selection.
  • NCV indicates proximity/levels but cannot replace a dedicated voltage absence tester for safety confirmation.
  • Limited input impedance for certain precision tasks (10 MΩ typical) compared with high-end meters.
  • Battery-powered (AAA) may be less convenient for heavy continuous use versus rechargeable solutions.
  • Certain advanced ranges show decreased usability in automatic mode, forcing extra steps for specific measurements.
M: OA-GPT-5-NAN

Product Specification

Measurement range

max. 300A, max. 1,000V, max. 30MΩ

M: OA-GPT-54-NAN

Product Description

Chauvin Arnoux CA 757 Multimeter — Practical, Rugged, and Versatile

The Chauvin Arnoux CA 757 Multimeter is a compact, professional-grade digital tester designed for electricians, technicians, and field service engineers. Lightweight and robust, it combines a backlit LCD, a five-position rotary switch, and a flexible MiniFlex current sensor to deliver reliable measurements across a broad set of tasks. Built to IEC safety standards, the CA 757 supports measurements up to 1000 V and 300 A ranges (with the MiniFlex sensor), with clear AC/DC detection, continuity, diode, resistance and capacitance functions, plus non-contact voltage (NCV) detection for rapid field checks.

This tester emphasizes safety and practicality. It is rated 600 V CAT III and meets IEC 61010 series requirements for leads and current sensor, with double insulation and protective guards to keep hands behind the safety barrier. The instrument includes removable probe tips, integrated probe storage on the back, and an automatic standby feature to preserve battery life. Supplied accessories include a MiniFlex MA101-250 current sensor, probe tips, AAA batteries, and a carrying bag—making it ready for on-site use.

Performance and usability matter: AC/DC auto-detection works above a defined threshold, while a Select button lets you lock functions (e.g., force DC/AC or select resistance/capacitance ranges). Resistance/continuity auto-selects ranges and sounds a buzzer below 30 Ω. Capacitance and high-resistance ranges are available in dedicated modes, and the current sensor measures single conductors with centering guidance for improved accuracy. NCV provides graduated auditory and visual alerts across four sensitivity levels, though absence of NCV indication should not be solely relied upon to confirm de-energized circuits.

The CA 757 was conceived with environmental responsibility in mind: it follows eco-design principles, is recyclable per ISO14040 lifecycle analysis, and bears WEEE guidance for proper disposal. Rugged construction (IP54, 2 m drop tested) and clear maintenance guidance (simple battery replacement, cleaning instructions) ensure long service life when used according to safety recommendations.

Whether for distribution panels, industrial equipment, or portable tool circuits, the CA 757 blends essential measurement functions with field-ready ergonomics and certified safety. It’s particularly suited for users who need a compact tester with flexible current measurement and reliable NCV capability.

Notes

  • Safety: Observe IEC category ratings and keep hands behind guards; do not measure live circuits for resistance/diode/capacitance.
  • Batteries: Uses two AAA (LR3) alkaline cells; replace when the battery symbol appears.
  • NCV: Use NCV as a detection aid only; confirm absence of voltage with a certified voltage tester.
M: OA-GPT-5-NAN