d131cf3b66b4d21dcdbf44924ab6b2b09bad page 3
3
en
General information
¡ Read this instruction manual carefully.
¡ Keep the instruction manual and the
product information safe for future refer-
ence or for the next owner.
¡ The appliance can only be used safely if it
is correctly installed according to the
safety instructions. The installer is re-
sponsible for ensuring that the appliance
works perfectly at its installation location.
¡ This instruction manual is intended for the
installer of the optional accessory.
¡ Only a licensed expert may connect the
appliance.
¡ Switch off the power supply before carry-
ing out any work.
Safe installation
Observe the safety instructions when installing the
optional accessory.
WARNING‒Risk of suffocation!
Children may put packaging material over their
heads or wrap themselves up in it and suffocate.
▶
Keep packaging material away from children.
▶
Do not let children play with packaging material.
WARNING‒Risk of injury!
Components inside the appliance may have sharp
edges.
▶
Wear protective gloves.
The odour filter remains hot for quite some time after
it has been regenerated.
▶
Do not touch the odour filter straight after it has
been regenerated – allow it to cool down.
Included with the appliance
After unpacking all parts, check for any damage in
transit and completeness of the delivery.
→Fig.
1
Establishing the pipework
1. Establish the pipework in such a way that the flex-
ible hose is flush with the cabinet base.
→Fig.
2
2. For circulating-air mode, establish an air outlet in
the unit's front toe kick.
The air outlet must have a minimum cross section
of approximately400cm². Make the outlet open-
ing in the base panel as large as possible in order
to keep draughts and noise to a minimum.
Fitting odour filters
1. Press ⁠.
a The glass panel moves up to halfway upwards
and grease filter cassettes are transported up-
wards.
2. Remove the grease filter cassettes.
→Fig.
3
3. Insert the odour filter cartridges.
→Fig.
4
4. Insert the grease filter cartridges.
→Fig.
5
5. Press ⁠.
a The glass panel and the filter cartridges move
downwards.
a The appliance flap closes and the appliance
switches off.
Regenerating the odour filter
To guarantee the odour filter power, regenerate the
odour filter with normal use (daily for approx.
onehour) every 3–4months. You can regenerate
the odour filter in a standard oven.
Leave the hot odour filter to cool down on a heat-res-
istant surface.
Notes
¡ You can regenerate the odour filter up to
30times. With normal use (daily for approx.
onehour), replace the odour filter at least every
10years.
¡ If a regenerable odour filter falls, it may become
damaged. The damage is not always visible from
the outside. Dispose of and replace any regener-
able odour filters that have fallen.
¡ Never clean odour filters with cleaning products,
water, in the dishwasher or with a damp cloth.
¡ To ensure that you do not scratch the baking tray,
place the odour filter on a wire rack.
¡ Regenerate the odour filter in the oven for
120minutes at a maximum of 200°C (air recircu-
lation ). Do not regenerate the odour filter with
the oven cleaning function (pyrolytic self-clean).
¡ Odours may develop when regenerating the odour
filter. Ensure that the room is well ventilated. Open
a window.
sv
Allmänna anvisningar
¡ Läs igenom anvisningen noga.
¡ Förvara bruksanvisningen och produktin-
formationen för senare användning eller
till nästa ägare.
¡ Säker användning av enheten kräver fack-
mässig montering enligt monteringsanvis-
ningen. Installatören ansvarar för en felfri
funktion på uppställningsplatsen.
¡ Anvisningen riktar sig till den som monte-
rar extratillbehöret.
¡ Det är bara behörig elektriker som får an-
sluta enheten.
¡ Slå alltid av elen innan du utför sådana ar-
beten.
Säker montering
Följ säkerhetsanvisningarna vid montering av extra-
tillbehöret.
VARNING!‒Kvävningsrisk!
Barn kan dra förpackningsmaterial över huvudet eller
trassla in sig i det och kvävas.
▶
Låt inte barn komma i närheten av förpacknings-
material.
▶
Låt inte barn leka med förpackningsmaterialet.
VARNING!‒Risk för personskador!
En del komponenter inuti enheten har vassa kanter.
▶
Använd alltid skyddshandskar.
Osfiltret förblir varmt långt efter regenereringen.
▶
Rör inte osfiltret direkt efter regenereringen, utan
låt det först svalna ordentligt.
Medföljande tillbehör
Kontrollera efter uppackningen att inga delar är
transportskadade och att leveransen är komplett.
→Fig.
1

Chat with your BSH Hausgerate Long Life Recirculation Kit manual using AI

Get instant AI answers from your BSH Hausgerate Long Life Recirculation Kit manual

Ask anything about the BSH Hausgerate Long Life Recirculation Kit. Answers come from this manual, with the pages they are based on.

Long Life Recirculation Kit Maintenance Schedule

Remind me when maintenance is due
Every 3-4 Months
Regenerate the odour filter

With normal use (approx. 1 hour daily), regenerate the odour filter in a standard oven at max 200°C for 120 minutes on a wire rack.

Every 10 Years
Replace the odour filter

With normal use (approx. 1 hour daily), replace the odour filter after a maximum of 10 years or after 30 regenerations.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend Long Life Recirculation Kit?

Yes No

Frequently Asked Questions

A

It converts a compatible cooker hood to recirculation operation. Cooking air passes through the odour filter before being returned to the kitchen, helping reduce cooking smells without requiring an external exhaust route.

Is this answer helpful?

A

With normal operation of approximately one hour per day, regenerate the odour filter every three to four months. Regular regeneration helps maintain effective odour absorption.

Is this answer helpful?

A

Remove the filter, place it on an oven rack, and regenerate it for 120 minutes in a hot-air oven at a maximum of 200 C. Ventilate the room and allow the filter to cool completely before reinstalling it.

Is this answer helpful?

A

No. Do not clean the filter with water, detergents, a damp cloth, or a dishwasher. These methods may damage the filter and reduce its odour-filtering performance.

Is this answer helpful?

A

The filter can be regenerated up to 30 times. Under normal use, it should be replaced no later than 10 years after installation.

Is this answer helpful?

A

The set requires secure fixing, drilling, hose fitting, and safe positioning near electrical components. Professional installation is advisable to ensure correct operation and avoid damage or injury.

Is this answer helpful?

M: gpt-5.6-terra

Advantages and Disadvantages

Advantages

  • Supports recirculation operation where external exhaust ducting is impractical or unavailable.
  • Long Life odour filter can be regenerated every 3-4 months, reducing routine replacement needs.
  • Filter may be regenerated up to 30 times when used and maintained as specified.
  • Includes key installation elements such as module, hose connection, mounting parts, and filter support.
VS

Disadvantages

  • Installation requires drilling and careful checks for electrical, gas, and water lines.
  • Correct fitting is important; professional installation is recommended for safe operation.
  • The odour filter is heavy and becomes hot during regeneration, requiring careful handling.
  • Filter cannot be washed and must be replaced if dropped, even when damage is not visible.
M: gpt-5.6-terra

Product Specification

Suitable for

Siemens/Bosch/Neff/Gaggenau/Constructa range hoods

M: gpt-5.6-terra

Product Description

BSH Hausgeräte Long Life Umluftset - Read, Download & Print Free

The BSH Hausgeräte Long Life Umluftset is designed to support recirculation operation in compatible cooker hoods. It combines a recirculation module, connection hose, mounting components, chimney-cover support parts, and an activated-carbon odour filter. Instead of venting cooking air outside, the system helps clean and return air to the kitchen, making it a practical option where an external duct is not available.

Cleaner recirculated kitchen air

At the centre of the set is a regenerative odour filter that captures cooking smells during daily hood operation. The filter is intended for homes that want a convenient recirculation solution while keeping the kitchen fresher during frying, boiling, and other everyday cooking tasks. A correctly fitted module and taut hose connection support effective airflow through the hood and filter.

The Long Life concept focuses on maintenance rather than frequent filter replacement. With normal use of around one hour per day, the odour filter should be regenerated every three to four months. This routine helps preserve its filtering performance and can extend its service life significantly.

Designed for careful installation

Installation requires secure wall fixing, accurate drilling, and proper positioning of the module in relation to the upper edge of the chimney cover. The mounting process includes fitting the module and bracket, connecting the hose with clamps, positioning the chimney cover, reinstalling the activated-carbon filter, and securing the panel.

Because the work involves wall drilling, electrical surroundings, sharp internal edges, and a heavy filter, careful preparation is essential. Check for electrical cables, gas pipes, and water pipes before drilling. Protective gloves are recommended, and all mounting elements must be firmly secured. For best results and safe operation, professional installation is advisable.

Regenerating the Long Life filter

To regenerate the odour filter, remove it carefully and place it on an oven rack to avoid scratching the baking tray. Preheat a conventional oven using hot-air circulation to a maximum of 200 C, then regenerate the filter for 120 minutes. Keep the room well ventilated, as odours may develop during the process. Allow the filter to cool fully on a heat-resistant surface before reinstalling it.

Notes

  • Do not wash the filter with water, cleaning products, a damp cloth, or in a dishwasher.
  • Do not use an oven pyrolytic cleaning program for regeneration.
  • A dropped filter should be replaced, even if damage is not visible.
  • The filter can be regenerated up to 30 times and should be replaced after no more than 10 years under normal use.
M: gpt-5.6-terra