Manual.ly Logo

Bosch Professional ProCORE 18V Starter Kit Manual

0.0 · 0 Ratings

PDF manual · 96 Pages

English

M: OA-GPT-54-NAN
page

/ 96

Loading...
da6ff06ef403e13b6e1b8a12d7ac3945682d page 8
8 | English
1 609 92A 4ET | (31.07.2018) Bosch Power Tools
Charger GAL 18V-40
– 5.0 Ah min (60)/70
– 6.0 Ah min (72)/95
Number of battery cells 3-15
Weight according to
EPTA-Procedure 01:2014
kg 0.55
Protection class / II
Operation
Start-up
u Note the mains voltage! The voltage of the power source
must match the voltage specified on the rating plate of
the charger. Chargers marked with 230V can also be op-
erated with 220V.
Charging process
The charging process begins as soon as the mains plug for
the charger is inserted into the mains socket and the battery
(1) is inserted into the charging slot (2).
Thanks to the intelligent charging process, the charge condi-
tion of the battery is automatically detected and then
charged up with the optimal charge current depending on
battery temperature and voltage.
In this way, the battery is treated with care and remains per-
manently fully charged when it is stored in the charger.
What the display elements mean
Flashing green battery charge level indicator (4)
The rapid-charging procedure is indicated by
flashing of the green battery charge level in-
dicator (4). The battery can be removed at any
time and used.
Note: The charging process is only possible when the tem-
perature of the battery is within the permitted charging tem-
perature range, see section "Technical data".
80 %
Once approx. 80% of the battery capacity has
been reached, the flashing of the green battery
charge indicator slows down. The rapid-char-
ging process is now completed. If the battery
remains in the charger, the charging process
will be completed in the Long Life charging mode.
Continuously illuminated green battery charge level
indicator (4)
The continuous light of the green battery
charge level indicator (4) signals that the bat-
tery is fully charged.
The battery can then be removed for immediate use.
When there is no battery connected, the continuous light of
the battery charge level indicator (4) indicates that the
mains plug is plugged into the mains socket and that the
charger is ready to be used.
Continuously illuminated red battery charge level
indicator (3)
The continuous light of the red battery charge
level indicator (3) shows that the temperature
of the battery is outside of the permitted char-
ging temperature range, see section "Technical
data". The charging process begins as soon as the permitted
temperature range has been reached.
Flashing red battery charge level indicator (3)
The flashing light of the red battery charge
level indicator (3) signals that the charging
process has been interrupted by a different
fault, see section "Errors – causes and correct-
ive measures".
Wall mounting
The charger can be used either free-standing (for use on a
desktop) or mounted on the wall.
When affixing to the wall: Drill two holes, leaving a clearance
as specified in the image.
To secure it, use round-head screws with a diameter of 5 mm
to max. 6.5 mm.
72 mm
Errors – Causes and Corrective Measures
Cause Corrective measures
Red battery charge level indicator (3) is flashing
Charging not possible
The battery is not connected
(correctly)
Connect battery to charger
correctly
Battery contacts are dirty Clean battery contacts; e.g.
by connecting and discon-
necting the battery several
times. Replace battery if ne-
cessary
Battery defective Replace battery
Green battery charge level indicator (4)/Red battery
charge level indicator (3) is not illuminated

Chat with your Bosch Professional ProCORE 18V Starter Kit manual using AI

Get instant AI answers from your Bosch Professional ProCORE 18V Starter Kit manual

Ask anything about the Bosch Professional ProCORE 18V Starter Kit. Answers come from this manual, with the pages they are based on.

ProCORE 18V Starter Kit Maintenance Schedule

Before each use
Inspect charger, cable and plug

Check the charger, cable and plug before every use. Do not use if damage is found.

As needed
Clean battery contacts

Clean dirty battery contacts by inserting and removing the battery several times or replace the battery.

M: QW-35-FL

Ask a Question

0/1000

Do you recommend ProCORE 18V Starter Kit?

Yes No

Frequently Asked Questions

A

The charging system is for Bosch Li-Ion batteries with automatic voltage detection in the range of 10.8 to 18V. It is intended for compatible Bosch Li-Ion packs and requires matching battery voltage to the charger.

Is this answer helpful?

A

Flashing green indicates rapid charging. Around 80 percent, the flashing slows down as the fast phase finishes. A steady green light means full charge. A steady red light means the battery temperature is outside the permitted range. Flashing red indicates another charging fault.

Is this answer helpful?

A

The provided timing data shows approximate charging durations by capacity. For 4.0Ah, the fast phase is listed at about 48 minutes, with full-charge completion at around 65 minutes. Actual times can vary with conditions.

Is this answer helpful?

A

Yes. When the battery is fully charged, the charger indicates completion with a steady green light. If the pack remains in the charger, charging is handled in a long-life mode so it stays prepared.

Is this answer helpful?

A

A steady red battery indicator means the battery temperature is outside the permitted charging range (0 to 45 C). Charging starts only after the battery returns to the acceptable temperature window.

Is this answer helpful?

A

Yes. The charger can be operated free-standing or mounted on the wall using two drill holes and round-head screws within the specified diameter range. Wall mounting helps keep the charging station organized.

Is this answer helpful?

A

First, ensure the battery is seated correctly and the mains plug is fully inserted. If the red indicator flashes, check for battery contact issues and clean contacts if needed. If the problem persists, the guidance recommends checking the power supply and having the charger serviced by an authorized Bosch after-sales center.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Intelligent charging automatically detects battery state and selects an optimal charge current based on temperature and voltage.
  • LED status indicators clearly communicate fast charge, full charge, temperature limits, and fault conditions.
  • Fast-charge workflow transitions after about 80 percent capacity to a finishing mode for careful charging.
  • Charger supports flexible placement: desktop use or wall mounting for tidier workspaces.
  • Repeated charging cycles may warm the charger, which is described as harmless and not a technical defect.
VS

Disadvantages

  • Charging depends on battery temperature staying within the permitted range (0 to 45 C).
  • If charging indicators flash red, a fault is indicated and troubleshooting is required.
  • Only compatible Bosch Li-Ion batteries with matching voltage and sufficient capacity should be charged.
  • If battery contacts are dirty or the battery is not seated correctly, charging may not start.
M: OA-GPT-54-NAN

Product Specification

Type

Starter Set

Charger

GAL18V-40

Battery

2x Battery (18V, 4.0Ah, Li-Ion)

M: GO-GEM-FL-25

Product Description

Bosch Professional Starter Kit ProCORE 18V, 4.0Ah, Lithium-Ion Manual - Smart 18V Power, Ready When You Are

A practical start for 18V projects

Bosch Professional Starter Kit ProCORE 18V, 4.0Ah, Lithium-Ion Manual is designed to help you move from setup to work quickly. The kit pairs Bosch ProCORE 18V battery capacity with a fast, controlled charging system, so your workflow stays consistent, whether you are working on-site or in a workshop.

Charging that adapts to your battery

At the heart of this starter setup is the GAL 18V-40 charger concept. It supports Li-Ion battery charging across 10.8 to 18V and uses an intelligent charging process that automatically detects the battery state. Instead of charging blindly, it adjusts the optimal charge current based on battery temperature and voltage. The result is careful battery treatment, plus the convenience of keeping batteries ready in the charging unit.

Clear status indicators for confidence

The charger gives straightforward visual feedback. A flashing green indicator signals rapid charging. When the battery reaches about 80 percent charge, the flashing slows down, indicating the fast phase is completing. A steady green light means the battery is fully charged and ready for immediate use. If the red indicator is steady, the battery temperature is outside the permitted range. A flashing red light points to a charging fault, so you can react quickly.

Built for real-world use

For flexibility, the charger can be used on a workbench or wall-mounted. Wall mounting uses two drill holes at the specified spacing and round-head screws, making it easy to keep the charging station organized.

Key results (why this kit makes sense)

  • Intelligent detection sets the optimal charge current based on battery temperature and voltage, helping extend battery care.
  • Rapid-charge workflow: fast charging starts immediately and transitions smoothly around 80 percent.
  • Clear indicators reduce guesswork: steady green for full charge, steady red for temperature limits, flashing red for faults.
  • Compact setup options: desktop use or wall mounting for better workshop organization.
  • Practical reliability: the charger may warm during repeated charging, which is normal and not a technical defect.

Notes

  • Use only Bosch Li-Ion batteries that meet the charger requirements, including capacity and voltage compatibility.
  • Keep ventilation slots unobstructed and avoid operating on easily flammable surfaces.
  • If runtime becomes significantly shorter after charging, the battery likely needs replacement.

Pros and cons from the charging experience

Pros

  • Intelligent charge control based on battery temperature and voltage.
  • Clear LED signals for fast charge, full charge, temperature issues, and faults.
  • Desktop or wall mounting for flexible workshop setups.
  • Fast charging behavior that transitions around 80 percent capacity.
  • Normal warming during continuous use is treated as safe operation.

Cons

  • Charging is only possible within the permitted battery temperature range (0 to 45 C).
  • Charging faults are signaled by flashing red, requiring troubleshooting.
  • You must use compatible Bosch Li-Ion batteries with matching voltage and sufficient capacity.
  • For best results, battery contacts may need cleaning if charging indicators do not light.
M: OA-GPT-54-NAN