Adjusting the Drilling Depth (see figure D)
The button (1) for depth stop adjustment can be used to set
the required drilling depthX.
– Press the button (1) and slide the button on the guide (2)
so that the distance X shown in the illustration matches
your required drilling depth.
– Release the button (1) again.
Changing the dust cap (see figureE)
You must change the dust cap(8) if its wall contact surface
shows clear signs of wear and is causing dust to escape
through the extraction brush during extraction.
– Press the locking button(12) and pull the dust cap(8)
out of the holder.
– Insert the new dust cap into the holder until the locking
button audibly engages.
Emptying the Dust Box (see figures F1−F4)
Note: Wear a dust mask when performing maintenance and
cleaning on the dust box.
Empty the dust box(13) regularly as well as after completing
your work, in order to ensure that the dust extraction attach-
ment continues to perform optimally. The viewing
window(7) enables you to check how full the dust box is.
– Hold the power tool with the dust extraction attachment
horizontally and switch on the power tool for a few
seconds.
This will cause residual dust to be sucked out of the ex-
traction channel into the dust box(13).
– Press both the left-hand and right-hand release
buttons(5) and swivel the dust box(13) out of the dust
extraction attachment.
– If necessary, take the HEPA filter(14) out of the dust box
and carefully tap it out or brush down the filter flaps with
a soft brush.
Note: Do not clean the HEPA filter with water and do not
use compressed air to blow it clean.
– Shake out the dust box(13) over a suitable waste bin.
– Put the HEPA filter(14) back in the dust box(13) after
cleaning it. Then swivel the dust box into the dust extrac-
tion attachment until the release buttons(5) audibly en-
gage.
Maintenance and Service
Maintenance and Cleaning
– Clean the dust extraction attachment using a dry, soft
cloth.
After-Sales Service and Application Service
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. You can find explosion drawings and information on
spare parts at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you
with any questions about our products and their accessor-
ies.
In all correspondence and spare parts orders, please always
include the 10‑digit article number given on the nameplate
of the product.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange
the collection of a product in need of servicing or repair.
Tel. Service: (0344) 7360109
You can find further service addresses at:
www.bosch-pt.com/serviceaddresses
Disposal
The dust extraction attachment, accessories and packaging
should be recycled in an environmentally friendly manner.
Do not dispose of the dust extraction attach-
ment along with household waste.
Only for United Kingdom:
According to The Waste Electrical and Electronic Equipment
Regulations 2013 (SI 2013/3113) (as amended), products
that are no longer usable must be collected separately and
disposed of in an environmentally friendly manner.
Français
Consignes de sécurité
Consignes de sécurité pour les dispositifs
d’aspiration
u Lisez et observez strictement les consignes de sécuri-
té figurant dans la notice de l’outil électroportatif uti-
lisé avec le dispositif d’aspiration.
u Retirez systématiquement l’accu avant toute interven-
tion sur l’outil électroportatif (montage, changement
d’accessoire, nettoyage, etc.). Il y a sinon risque de
blessure si vous appuyez par mégarde sur l’interrupteur
Marche/Arrêt.
u Attentionrisque d’incendie! N’utilisez pas le disposi-
tif d’aspiration pour effectuer des perçages dans du
métal. Les copeaux métalliques chauds risquent d’en-
flammer certaines pièces du bac récupérateur de pous-
sières.
Bosch Power Tools 1 609 92A 7EM | (21.02.2023)

Chat with your Bosch Professional GDE 18V-12 manual using AI

Get instant AI answers from your Bosch Professional GDE 18V-12 manual

Ask anything about the Bosch Professional GDE 18V-12. Answers come from this manual, with the pages they are based on.

GDE 18V-12 Maintenance Schedule

Regularly / After each use
Empty the dust box

Empty the dust box regularly and after completing work to maintain optimal suction performance. Wear a dust mask during this process.

As needed
Clean or replace HEPA filter

Tap out or brush filter flaps with a soft brush if dirty. Do not clean with water or compressed air. Replace immediately if damaged.

When worn
Replace the dust cap

Replace the dust cap if its wall contact surface shows clear signs of wear and dust escapes through the extraction brush.

After use
Relieve guide spring tension

Before storage, press the drill bit length adjustment button and pull the guide all the way out to relieve spring strain and extend service life.

Regularly
Clean the attachment exterior

Clean the dust extraction attachment using a dry, soft cloth.

M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend GDE 18V-12?

Yes No

Frequently Asked Questions

A

This unit is designed exclusively for drilling in concrete, brick, stone, ceramic, and tiles. It must not be used on wood, metal, or plastic materials.

Is this answer helpful?

A

It operates specifically with the GBH 18V-22 rotary hammer model. Ensure you have the correct adapter guide for proper fitment.

Is this answer helpful?

A

Yes, a battery capacity greater than 3.0 Ah is required. A blinking light indicates insufficient battery power for expected performance.

Is this answer helpful?

A

Tap the filter gently to remove dust or brush the lamellae with a soft brush. Do not wash with water or use compressed air.

Is this answer helpful?

A

Hot metal chips generated during drilling can ignite parts of the dust container, posing a serious fire hazard.

Is this answer helpful?

A

Empty the box regularly and immediately after finishing work to maintain optimal suction capabilities and prevent clogging.

Is this answer helpful?

A

You should always wear ear protectors against noise exposure and a dust mask when maintaining or cleaning the dust collection system.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Captures 99.97% of particles over 0.3 microns via HEPA filter
  • Compatible with popular rotary hammer models like GBH 18V-22
  • Integrated LED worklight improves visibility in dark areas
  • Audible engagement ensures secure fitting to the tool
  • Viewing window allows users to monitor dust fill levels easily
VS

Disadvantages

  • Not suitable for use on metal materials due to fire risk
  • Requires minimum battery capacity of 3.0 Ah for full operation
  • HEPA filter must be dry brushed rather than washed with water
  • Attachment must be held by tool handles, not the extractor itself
  • Guide spring requires specific release procedure for long term storage
M: QW-35-FL

Product Specification

Fits

Bosch Professional GBH 18V-22 Cordless Rotary Hammer

M: QW-35-FL

Product Description

Discover Superior Dust Control with the Bosch Professional GDE 18V-12 Dust Extraction

Managing dust during construction projects is critical for health and safety standards on every job site. The Bosch Professional GDE 18V-12 Dust Extraction offers a robust solution designed specifically for demanding drilling applications. This high-performance attachment is engineered to capture drilling dust effectively when working with hard materials like concrete, brick, stone, ceramic, and tiles. However, it is vital to note that this unit should never be used on wood, metal, or plastic. Using it on metal poses a significant fire hazard because hot metal chips can ignite parts of the dust container.

Key Features and Specifications

Designed for seamless integration, this device fits directly onto compatible rotary hammers, specifically the GBH 18V-22 model listed in the documentation. Proper alignment is ensured through precision housing guides that allow for a secure audible click during installation. The system includes essential safety components such as a viewing window to monitor internal dust levels and a locking button for easy access to the waste box. An integrated LED worklight illuminates dark areas when the power tool is activated, significantly enhancing visibility on the job site during low-light conditions. Users must ensure a battery capacity greater than 3.0 Ah is connected for optimal performance, which is clearly indicated by the status behavior of the LED light system. Safety warnings emphasize removing the battery before any work on the tool to avoid injury from unintentional switch activation. Adherence to these operational steps guarantees a professional grade outcome for your drilling projects involving heavy masonry work.

Installation and Usage Instructions

Installing the attachment requires aligning the housing guide of the extractor with the hammer and sliding it firmly into place until it engages. To remove it safely, simply press both release buttons simultaneously while pulling the unit away from the hammer body. Detailed adjustments are made easily using specific buttons located on the guide rail for drill bit length and drilling depth settings. Users can set the depth stop accurately to prevent accidental over-drilling into substrates. Maintaining the correct guide length ensures the drill tip remains perfectly flush with the dust cap for maximum suction efficiency across all operations. Maximum drilling diameter supported ranges from four to twelve millimeters. Storage recommendations suggest releasing tension on the guide spring to increase longevity.

Maintenance and Care Protocols

Regular maintenance is required to keep the system running smoothly throughout its lifespan. The dust box must be emptied regularly after work sessions to maintain optimal suction power. Cleaning involves carefully tapping out accumulated debris or gently brushing the included HEPA filter elements. This specific filter removes approximately 99.97 percent of all particles larger than 0.3 micrometers effectively. Never clean the filter with water or attempt to blow it out with compressed air as this damages the material. Always wear appropriate personal protective equipment including ear protection and a dust mask during all maintenance tasks. Holding the tool firmly by its handles rather than the attachment ensures safe handling during operation. Disposal instructions require recycling these units responsibly without placing them in standard household waste bins. Regular inspection of the dust cap prevents leakage and maintains the seal integrity during continuous usage cycles.

M: QW-35-FL

© Copyright 2026 Manual.ly