LB 45 Maintenance Schedule
Clean the ultrasound membrane with a cotton bud and empty/rinse the water from the base unit via the side rim.
Rinse the water tank and fill it with fresh warm water (30-45°C).
Wipe the interior and exterior of the device with a damp cloth using mild detergent or vinegar-based cleaner.
If the device is used daily, clean the water tank at least once a week using a soft brush and mild detergent or vinegar.
The service life of the anti-limescale filter is maximum 2-3 months. Replace it if limescale builds up despite the filter.
Apply descaler to the ultrasound membrane and base, let act for 2-5 minutes, then clean with brush and rinse thoroughly.
If the device has not been used for more than one week, completely empty the humidifier and clean the water tank before reuse.
Free maintenance reminders
Timed to your purchase date. Always free, unsubscribe anytime.
Ask a Question
Do you recommend LB 45?
Yes NoFrequently Asked Questions
Clean the ultrasonic membrane every three days or as needed. Rinse the tank regularly to maintain hygiene.
Is this answer helpful?
No, do not add essential oils directly into the water. Use the aroma pad in the compartment instead.
Is this answer helpful?
The device comes with a three-year warranty from the purchase date.
Is this answer helpful?
Use warm water between 30 and 45 degrees Celsius to prevent leakage.
Is this answer helpful?
Use a descaler solution on the membrane and rinse thoroughly with fresh water.
Is this answer helpful?
Children over eight years old can use it under supervision but should not play with the device.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Ultrasonic technology ensures quiet operation for sleeping areas.
- Large 4 liter tank reduces refill frequency.
- Automatic shut-off prevents damage when water runs low.
- Suitable for rooms up to 30 square meters.
- Includes aroma compartment for scenting.
Disadvantages
- Manual filling required for water tank.
- Regular cleaning needed every three days.
- Optional filter needed for hard water.
- Essential oils cannot be added directly to water.
- Requires stable surface to avoid water leakage.
Product Specification
Type
Atomizing principle (ultrasonic technology)
Power
25 W
Color
white, black
Recommended room size
up to 322.92 sq ft
Power levels
stepless
Humidification output
1.90 gal / 24h
Water tank capacity
1.06 gal
Features
Aroma function, automatic shut-off (when tank empty), descaling cartridge
Dimensions
8.35x12.48x5.87 in (WxHxD)
Weight
3.31 lbs
Product Description
Improving Indoor Air Quality Today
Humans spend the majority of their time inside enclosed rooms. For optimal health and comfort, a relative humidity of 40 to 60 percent is ideal. However, winter heating often reduces this moisture significantly. Dry air causes mucous membranes to dry out, eyes to burn, and dust levels to rise. It can also damage wooden furniture and musical instruments. The Beurer LB 45 Air Humidifier addresses these environmental challenges effectively.
Device Capabilities and Performance
This appliance operates on ultrasonic technology. A vibrating membrane lifts microscopic particles from the water surface. A fan pulls air from below, mixes it with moisture, and releases it upward. It covers spaces up to 30 square meters efficiently. The maximum capacity holds 4 liters. You do not have to refill often. The device is energy efficient and switches off when the tank is empty to prevent damage. It runs quietly so it does not disturb rest.
Usage Guidelines and Safety
Safety notes emphasize disconnecting power during maintenance. The unit is for private indoor use only. Do not use it in bathrooms or saunas. Fill the tank with warm water between 30 and 45 degrees Celsius to prevent leakage. Do not add essential oils directly into the water. Use the included aroma pad for scenting. Ensure the water level indicator glows blue when running. A red light signals a low water level causing automatic shutdown. Children over eight can use it under supervision. Never play with the device.
Maintenance Protocols
Hygiene requires regular care. Clean the ultrasonic membrane with a cotton swab. Rinse the base and tank regularly. If limescale forms, use a descaler agent. An optional filter helps if water quality is poor. Empty the tank if not used for a week to prevent stagnation. Follow the Beurer LB 45 Air Humidifier Manual for deep cleaning steps. The manual also lists replacement parts like aroma pads and filters. Ensure no water enters the housing interior.
Technical Specifications and Support
Dimensions are approximately 25 by 12 by 34 centimeters. The cable length is 1.5 meters. Power consumption is 25 watts. It accepts voltages from 100 to 240 volts. Warranty covers defects for three years from purchase. Contact customer service for repairs if needed. Proper disposal follows electronic waste regulations. This device supports a healthier home environment. Troubleshooting tips help resolve common issues like strange noises or lack of mist quickly. Enjoy a balanced atmosphere with this reliable appliance. If mist escapes from the tank area, check the seal. Ensure the device stands on a stable surface to prevent spills. This ensures longevity.
Search for 67,732 Manuals online
Type-in Brand or Model
Thomas Mueller
5 months ago
Why does the humidifier leak water frequently during use and filling? Also, is it common for parts to break without being dropped?
Manual.ly
5 months ago
We apologize for these experiences. Leakage and breakage are known issues with this model due to the valve design and plastic durability. If your unit leaks excessively or parts break, please contact us immediately for a replacement or refund. We prioritize customer satisfaction and safety.